Most cited article - PubMed ID 35861976
Wireless Communication Between Paired Leadless Pacemakers for Dual-Chamber Synchrony
AIMS: A dual-chamber leadless pacemaker (LP) system that employs distinct atrial and ventricular LP devices (ALP, VLP) has been introduced to clinical practice. Proprietary, low-energy, implant-to-implant (i2i) communication at each beat enables the devices to maintain synchronous atrioventricular sensing and pacing. We evaluated device longevities and contributing factors, such as i2i communication. METHODS AND RESULTS: Patients meeting dual-chamber pacing indications received the dual-chamber LP system as part of a prospective, multi-centre, international clinical trial (Aveir DR i2i Study, NCT05252702). Programming and diagnostics were interrogated from all de novo, non-revised, dual-chamber programmed devices at 12 months post-implant. This analysis included 302 patients (65% male; age 70 ± 13 years; weight 80 ± 19 kg; intrinsic heart rate 55 ± 7 bpm; 58% sinus node dysfunction, 27% atrioventricular block). At 12 months, devices were programmed to dual-chamber pacing (DDD(R) or DDI(R)) at a median 60 bpm rate, median 1.25 V pulse amplitude in ALP and 1.5 V in VLP, median 0.4 ms pulse width, and median i2i signal setting level 5 out of 7. Median ALP and VLP remaining battery longevities at 12 months were 4.3 and 9.1 years, with median total ALP and VLP longevities of 5.3 and 9.9 years. Base rate, pulse amplitude, pacing percentage, event rate, impedance, and i2i setting level all exhibited significant correlations with ALP and VLP longevities (P < 0.001). Programming i2i setting levels below 7 produced the greatest longevity savings. CONCLUSION: The first dual-chamber LP demonstrated adequate projected battery longevity after 12 months of use. Patient-specific device programming considerations, unique to leadless devices, may extend longevity.
- Keywords
- Aveir, Battery longevity, Dual-chamber, Leadless pacemaker,
- MeSH
- Atrioventricular Block therapy diagnosis physiopathology MeSH
- Time Factors MeSH
- Equipment Design MeSH
- Cardiac Pacing, Artificial * methods MeSH
- Pacemaker, Artificial * MeSH
- Middle Aged MeSH
- Humans MeSH
- Prospective Studies MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Arrhythmias, Cardiac * therapy diagnosis physiopathology MeSH
- Heart Rate MeSH
- Treatment Outcome MeSH
- Electric Power Supplies * MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Multicenter Study MeSH