Permanent pacing Dotaz Zobrazit nápovědu
BACKGROUND: We evaluated the effects of the site of ventricular pacing on left ventricular (LV) synchrony and function in children requiring permanent pacing. METHODS AND RESULTS: One hundred seventy-eight children (aged <18 years) from 21 centers with atrioventricular block and a structurally normal heart undergoing permanent pacing were studied cross-sectionally. Median age at evaluation was 11.2 (interquartile range, 6.3-15.0) years. Median pacing duration was 5.4 (interquartile range, 3.1-8.8) years. Pacing sites were the free wall of the right ventricular (RV) outflow tract (n=8), lateral RV (n=44), RV apex (n=61), RV septum (n=29), LV apex (n=12), LV midlateral wall (n=17), and LV base (n=7). LV synchrony, pump function, and contraction efficiency were significantly affected by pacing site and were superior in children paced at the LV apex/LV midlateral wall. LV dyssynchrony correlated inversely with LV ejection fraction (R=0.80, P=0.031). Pacing from the RV outflow tract/lateral RV predicted significantly decreased LV function (LV ejection fraction <45%; odds ratio, 10.72; confidence interval, 2.07-55.60; P=0.005), whereas LV apex/LV midlateral wall pacing was associated with preserved LV function (LV ejection fraction ≥55%; odds ratio, 8.26; confidence interval, 1.46-47.62; P=0.018). Presence of maternal autoantibodies, gender, age at implantation, duration of pacing, DDD mode, and QRS duration had no significant impact on LV ejection fraction. CONCLUSIONS: The site of ventricular pacing has a major impact on LV mechanical synchrony, efficiency, and pump function in children who require lifelong pacing. Of the sites studied, LV apex/LV midlateral wall pacing has the greatest potential to prevent pacing-induced reduction of cardiac pump function.
- MeSH
- atrioventrikulární blokáda patologie patofyziologie terapie MeSH
- dítě MeSH
- dysfunkce levé srdeční komory diagnostické zobrazování patofyziologie MeSH
- elektrokardiografie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- mladiství MeSH
- modely kardiovaskulární MeSH
- průřezové studie MeSH
- rentgendiagnostika hrudníku MeSH
- retrospektivní studie MeSH
- srdeční komory diagnostické zobrazování patologie patofyziologie MeSH
- tepový objem fyziologie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
A total of 63 patients with combined intraventricular block with a 60.3% mortality were found among 725 patients with acute myocardial infarction (AMI) with a 20.5% mortality. 25 patients with combined intraventricular blocks survived the hospitalization period--permanent pacing having been introduced in 11 of them. The mean survival time in them was 21.7 months. There were 3 deaths (27.3%), none of them sudden. The remaining 14 patients without pacing survived for a mean period of 15.9 months, with 7 deaths (50%), four of which could be designed as sudden. The authors conclude that permanent pacing "on demand" is indicated in all patients surviving the hospitalization period after AMI complicated by advanced a-v block and after anterior AMI following an older MI with new bilateral His bundle branch block.
- MeSH
- infarkt myokardu mortalita terapie MeSH
- kardiostimulace umělá * MeSH
- lidé MeSH
- srdeční blokáda komplikace mortalita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: His-Bundle pacing (HBP) is an emerging technique for physiological pacing. However, its effects on right ventricle (RV) performance are still unknown. METHODS: We enrolled consecutive patients with an indication for pacemaker (PM) implantation to compare HBP versus RV pacing (RVP) effects on RV performance. Patients were evaluated before implantation and after 6 months by a transthoracic echocardiogram. RESULTS: A total of 84 patients (age 75.1±7.9 years, 64% male) were enrolled, 42 patients (50%) underwent successful HBP, and 42 patients (50%) apical RVP. At follow up, we found a significant improvement in RV-FAC (Fractional Area Change)% [baseline: HBP 34 IQR (31-37) vs. RVP 33 IQR (29.7-37.2),p = .602; 6-months: HBP 37 IQR (33-39) vs. RVP 30 IQR (27.7-35), p < .0001] and RV-GLS (Global Longitudinal Strain)% [baseline: HBP -18 IQR (-20.2 to -15) vs. RVP -16 IQR (-18.7 to -14), p = .150; 6-months: HBP -20 IQR(-23 to -17) vs. RVP -13.5 IQR (-16 to -11), p < .0001] with HBP whereas RVP was associated with a significant decline in both parameters. RVP was also associated with a significant worsening of tricuspid annular plane systolic excursion (TAPSE) (p < .0001) and S wave velocity (p < .0001) at follow up. Conversely from RVP, HBP significantly improved pulmonary artery systolic pressure (PASP) [baseline: HBP 38 IQR (32-42) mmHg vs. RVP 34 IQR (31.5-37) mmHg,p = .060; 6-months: HBP 32 IQR (26-38) mmHg vs. RVP 39 IQR (36-41) mmHg, p < .0001] and tricuspid regurgitation (p = .005) irrespectively from lead position above or below the tricuspid valve. CONCLUSIONS: In patients undergoing PM implantation, HBP ensues a beneficial and protective impact on RV performance compared with RVP.
- Klíčová slova
- His-Bundle pacing, conduction system pacing, echocardiogram, pacemaker, right ventricle,
- MeSH
- dysfunkce pravé srdeční komory patofyziologie terapie MeSH
- Hisův svazek patofyziologie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- senioři MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: To evaluate the results of permanent epicardial pacing in children. METHODS AND RESULTS: All consecutive patients from one country (n = 119, period 1977-2009) undergoing permanent epicardial pacemaker implantation at <18 years of age (median 1.8 years, inter-quartile range 0.3-6.4 years) were studied retrospectively. Median patient follow up was 6.4 years (inter-quartile range 2.9-11.1 years); 207 generators, 89 atrial and 153 ventricular pacing leads were implanted. The probability of absence of any pacing system dysfunction was 70.1 and 47.2% at 5 and 10 years after implantation, respectively. Overall probability of continued epicardial pacing was 92.8 and 76.1% at 5 and 10 years, respectively, and increased in the recent implantation era (post-2000, P = 0.04). The use of steroid-eluting leads decreased the risk of exit block with a hazard ratio (HR) of 0.20 [95% confidence interval (CI) 0.09-0.44, P < 0.001)]. The use of bipolar Medtronic 4968 leads reduced the risk of surgical reintervention because of fracture, insulation break, outgrowth or exit block in comparison to the unipolar 4965 lead design (HR 0.12, 95% CI 0.04-0.40, P < 0.001). The AutoCapture™ feature (HR 0.08, 95% CI 0.02-0.36, P < 0.001) and steroid-eluting leads (HR 0.30, 95% CI 0.11-0.84, P = 0.021) decreased the risk of battery depletion. CONCLUSION: The probability of continued epicardial pacing in children was 76% at 10 years after implantation, increased for implantation in recent years, and allowed transvenous pacing to be deferred to a significantly greater age. The use of bipolar steroid-eluting leads and of a beat-to-beat capture tracking feature significantly increased pacing system longevity and decreased the need for surgical reinterventions.
- MeSH
- dítě MeSH
- hodnocení rizik MeSH
- kardiostimulace umělá statistika a číselné údaje MeSH
- kojenec MeSH
- lidé MeSH
- longitudinální studie MeSH
- perikard * MeSH
- předškolní dítě MeSH
- rizikové faktory MeSH
- srdeční arytmie epidemiologie prevence a kontrola MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
From the point of view of established practice, redundant permanent pacing leads have been abandoned or extracted using various catheter-based procedures. An unusual complication was caused by failed surgical lead extraction resulting in electrode severing and wire unbraiding with subsequent induction of electric interaction between the metallic, noninsulated part of the lead fragment and the defibrillating electrode. This interaction was sensed and detected by the ICD system. A modified catheter-based extraction procedure is described.
- MeSH
- cizí tělesa terapie MeSH
- dospělí MeSH
- implantované elektrody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- odstranění implantátu MeSH
- selhání zařízení MeSH
- srdeční katetrizace přístrojové vybavení metody MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
BACKGROUND: Several studies have shown that unnecessary right ventricular pacing has detrimental effects. OBJECTIVE: To evaluate whether minimization of ventricular pacing as compared with standard dual-chamber pacing (DDD) improves clinical outcomes in patients referred for pacemaker or implantable cardioverter-defibrillator (ICD) replacement. METHODS: In an international single-blind, multicenter, randomized controlled trial, we compared DDD with managed ventricular pacing (MVP), a pacing mode developed to minimize ventricular pacing by promoting intrinsic atrioventricular conduction. We included patients referred for device replacement with >40% ventricular pacing, no cardiac resynchronization therapy upgrade indication, no permanent atrial fibrillation (AF), and no permanent complete atrioventricular block. Follow-up was for 2 years. The primary end point was cardiovascular hospitalization. The intention-to-treat analysis was performed by using Kaplan-Meier method and the log-rank test. RESULTS: We randomized 605 patients (556 referred for pacemaker and 49 referred for ICD replacement; mean age 75 ± 11 years; 365 [60%] men, at 7.7 ± 3.3 years from first device implantation) to MVP (n = 299) or DDD (n = 306). We found no significant differences in the primary end point cardiovascular hospitalization (MVP: 16.3% vs DDD: 14.5%; P = .72) and the secondary end point persistent AF (MVP: 15.4% vs DDD: 11.2%; P = .08), permanent AF (MVP: 4.1% vs DDD: 3.1%; P = .44), and composite of death and cardiovascular hospitalization (MVP: 23.9% vs DDD: 20.2%; P = .48). MVP reduced right ventricular pacing (median 5% vs 86%; Wilcoxon, P < .0001) as compared with DDD. CONCLUSIONS: In patients referred for pacemaker and ICD replacement with clinically well-tolerated long-term exposure to >40% ventricular pacing in the ventricle, a strategy to minimize ventricular pacing is not superior to standard DDD in reducing incidence of cardiovascular hospitalizations.
- Klíčová slova
- Cardiac pacing, Dual-chamber pacing, Managed ventricular pacing, Outcomes, Randomized controlled trial,
- MeSH
- analýza podle původního léčebného záměru MeSH
- defibrilátory implantabilní MeSH
- fibrilace komor terapie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
BACKGROUND: Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. METHODS AND RESULTS: The primary safety end point was freedom from complications at 90 days. Secondary performance end points included implant success rate, implant time, and measures of device performance (pacing/sensing thresholds and rate-responsive performance). The mean age of the patient cohort (n=33) was 77±8 years, and 67% of the patients were male (n=22/33). The most common indication for cardiac pacing was permanent atrial fibrillation with atrioventricular block (n=22, 67%). The implant success rate was 97% (n=32). Five patients (15%) required the use of >1 leadless cardiac pacemaker during the procedure. One patient developed right ventricular perforation and cardiac tamponade during the implant procedure, and eventually died as the result of a stroke. The overall complication-free rate was 94% (31/33). After 3 months of follow-up, the measures of pacing performance (sensing, impedance, and pacing threshold) either improved or were stable within the accepted range. CONCLUSIONS: In a prospective nonrandomized study, a completely self-contained, single-chamber leadless cardiac pacemaker has shown to be safe and feasible. The absence of a transvenous lead and subcutaneous pulse generator could represent a paradigm shift in cardiac pacing. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT01700244.
- Klíčová slova
- cardiac, pacemaker,
- MeSH
- design vybavení * MeSH
- incidence MeSH
- kardiostimulátor * MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- pooperační komplikace epidemiologie MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční arytmie terapie MeSH
- studie proveditelnosti MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
Cardiac pacing is reckoned to be one of the most successful branches of medicine in the second half of the 20th century. Indications for single chamber ventricular pacing are getting gradually restricted. This early pacing mode, which was used in 1958 for the first time, has been recently replaced from modern modes: for atrial, dual chamber and rate adaptive ones. Not only these most recent methods prevent from bradycardia but they also meet demands of modern cardiac pacing, i.e. to restore the synchronization of the atriums and the ventricles and to restore the frequency response. So-called physiological pacing improves both the well-being and the survival of patients and it has also extended pacing indications to the non-arrhythmic ones: first and foremost to the cardiomyopathies. It is dual chamber pacing, the artificial biosensors, various kinds of counters and monitoring functions that enhance the energy consumption. Both low-threshold pacing leads and an automatic adjustment of the pulse energy are helpful in extending the longevity of tiny lithium-powered pacemakers of these days. Current dual chamber rate responsive devices represent an important first step towards a fully automatic smart pacemaker of the future. Such an intelligent pulse generator with several sensors will be operating in the DDDR mode checking automatically the pacing threshold and switching its pacing mode according to pathophysiological requirements.
- MeSH
- kardiostimulace umělá * MeSH
- kardiostimulátor MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- přehledy MeSH
- MeSH
- bezpečnost vybavení MeSH
- elektrokardiografie * MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- následné studie MeSH
- selhání zařízení MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
His bundle pacing is a relatively new method of cardiac pacing. This method is used in patients with atrioventricular block to prevent heart failure associated with right ventricular pacing, and in patients with bundle branch block and cardiomyopathy. We report a patient with cardiomyopathy and left bundle branch block with failure of cardiac resynchronization therapy. Permanent His bundle pacing was associated with clinical improvement and improvement of parameters of cardiac function.
- Klíčová slova
- His bundle pacing, cardiac resynchronization therapy, cardiomyopathy, heart failure, left bundle branch block, left ventricular ejection fraction,
- MeSH
- blokáda Tawarova raménka diagnóza etiologie patofyziologie chirurgie MeSH
- dilatační kardiomyopatie komplikace diagnóza patofyziologie chirurgie MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční fyziologie MeSH
- Hisův svazek fyziologie MeSH
- implantované elektrody MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor MeSH
- lidé MeSH
- senioři MeSH
- srdeční katetrizace přístrojové vybavení metody MeSH
- srdeční resynchronizační terapie škodlivé účinky MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH