The biocompatibility of polyaniline and polypyrrole: A comparative study of their cytotoxicity, embryotoxicity and impurity profile

P. Humpolíček, V. Kašpárková, J. Pacherník, J. Stejskal, P. Bober, Z. Capáková, KA. Radaszkiewicz, I. Junkar, M. Lehocký,

. 2018 ; 91 (-) : 303-310. [pub] 20180516

Jazyk angličtina Země Nizozemsko

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19000531

Conducting polymers (CP), namely polyaniline (PANI) and polypyrrole (PPy), are promising materials applicable for the use as biointerfaces as they intrinsically combine electronic and ionic conductivity. Although a number of works have employed PANI or PPy in the preparation of copolymers, composites, and blends with other polymers, there is no systematic study dealing with the comparison of their fundamental biological properties. The present study, therefore, compares the biocompatibility of PANI and PPy in terms of cytotoxicity (using NIH/3T3 fibroblasts and embryonic stem cells) and embryotoxicity (their impact on erythropoiesis and cardiomyogenesis within embryonic bodies). The novelty of the study lies not only in the fact that embryotoxicity is presented for the first time for both studied polymers, but also in the elimination of inter-laboratory variations within the testing, such variation making the comparison of previously published works difficult. The results clearly show that there is a bigger difference between the biocompatibility of the respective polymers in their salt and base forms than between PANI and PPy as such. PANI and PPy can, therefore, be similarly applied in biomedicine when solely their biological properties are considered. Impurity content detected by mass spectroscopy is presented. These results can change the generally accepted opinion of the scientific community on better biocompatibility of PPy in comparison with PANI.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19000531
003      
CZ-PrNML
005      
20240717093704.0
007      
ta
008      
190107e20180516ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.msec.2018.05.037 $2 doi
035    __
$a (PubMed)30033259
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Humpolíček, Petr $u Centre of Polymer Systems, Tomas Bata University in Zlin, 760 01 Zlin, Czech Republic. Electronic address: humpolicek@utb.cz.
245    14
$a The biocompatibility of polyaniline and polypyrrole: A comparative study of their cytotoxicity, embryotoxicity and impurity profile / $c P. Humpolíček, V. Kašpárková, J. Pacherník, J. Stejskal, P. Bober, Z. Capáková, KA. Radaszkiewicz, I. Junkar, M. Lehocký,
520    9_
$a Conducting polymers (CP), namely polyaniline (PANI) and polypyrrole (PPy), are promising materials applicable for the use as biointerfaces as they intrinsically combine electronic and ionic conductivity. Although a number of works have employed PANI or PPy in the preparation of copolymers, composites, and blends with other polymers, there is no systematic study dealing with the comparison of their fundamental biological properties. The present study, therefore, compares the biocompatibility of PANI and PPy in terms of cytotoxicity (using NIH/3T3 fibroblasts and embryonic stem cells) and embryotoxicity (their impact on erythropoiesis and cardiomyogenesis within embryonic bodies). The novelty of the study lies not only in the fact that embryotoxicity is presented for the first time for both studied polymers, but also in the elimination of inter-laboratory variations within the testing, such variation making the comparison of previously published works difficult. The results clearly show that there is a bigger difference between the biocompatibility of the respective polymers in their salt and base forms than between PANI and PPy as such. PANI and PPy can, therefore, be similarly applied in biomedicine when solely their biological properties are considered. Impurity content detected by mass spectroscopy is presented. These results can change the generally accepted opinion of the scientific community on better biocompatibility of PPy in comparison with PANI.
650    12
$a aniliny $x škodlivé účinky $x farmakologie $7 D000814
650    _2
$a zvířata $7 D000818
650    _2
$a embryoidní tělíska $x metabolismus $x patologie $7 D058732
650    _2
$a erytropoéza $x účinky léků $7 D004920
650    12
$a testování materiálů $7 D008422
650    _2
$a myši $7 D051379
650    _2
$a myší embryonální kmenové buňky $x metabolismus $x patologie $7 D000066450
650    _2
$a kardiomyocyty $x metabolismus $x patologie $7 D032383
650    _2
$a buňky NIH 3T3 $7 D041681
650    12
$a polymery $x škodlivé účinky $x farmakologie $7 D011108
650    12
$a pyrroly $x škodlivé účinky $x farmakologie $7 D011758
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kašpárková, Věra $u Centre of Polymer Systems, Tomas Bata University in Zlin, 760 01 Zlin, Czech Republic.
700    1_
$a Pacherník, Jiří $u Institute of Experimental Biology, Faculty of Science, Masaryk University, 625 00 Brno, Czech Republic.
700    1_
$a Stejskal, Jaroslav $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, 162 06 Prague 6, Czech Republic.
700    1_
$a Bober, Patrycja $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, 162 06 Prague 6, Czech Republic.
700    1_
$a Capáková, Zdenka $u Centre of Polymer Systems, Tomas Bata University in Zlin, 760 01 Zlin, Czech Republic.
700    1_
$a Radaszkiewicz, Katarzyna $u Institute of Experimental Biology, Faculty of Science, Masaryk University, 625 00 Brno, Czech Republic. $7 xx0320047
700    1_
$a Junkar, Ita $u Josef Stefan Institute, Jamova 39, Ljubljana 1000, Slovenia.
700    1_
$a Lehocký, Marián $u Centre of Polymer Systems, Tomas Bata University in Zlin, 760 01 Zlin, Czech Republic.
773    0_
$w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 91 (20180516), s. 303-310
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30033259 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190107 $b ABA008
991    __
$a 20240717093659 $b ABA008
999    __
$a ok $b bmc $g 1364592 $s 1038654
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 91 $c - $d 303-310 $e 20180516 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
LZP    __
$a Pubmed-20190107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...