Novel electrophoretic acetonitrile-based stacking for sensitive monitoring of the antiepileptic drug perampanel in human serum
P. Tůma, M. Bursová, B. Sommerová, R. Horsley, R. Čabala, T. Hložek,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, validační studie
- MeSH
- acetonitrily chemie MeSH
- antikonvulziva MeSH
- elektroforéza kapilární metody MeSH
- fluorescence MeSH
- kalibrace MeSH
- lidé MeSH
- limita detekce MeSH
- monitorování léčiv metody MeSH
- pyridony krev MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
Perampanel is a novel antiepileptic drug used in paediatric patients. Existing methods that determine serum perampanel are of limited practicability. We developed a novel capillary electrophoresis (CE) method using a new version of acetonitrile stacking for on-line sample pre-concentration, and fluorescence detection (FD). CE separations were performed in a fused-silica capillary where the electroosmotic flow was reduced by coating the inner surface using a INST coating solution. The optimised background electrolyte composition was 50 mM chloroacetic acid with addition of 0.5% m/v polyvinylalcohol (pH 2.15) and separation was driven by application of positive voltage + 30 kV. Serum samples (25 μL) treated by the addition of acetonitrile in a ratio of 1:3 v/v were each injected into the capillary at a large volume that corresponded to the length (129 mm) of the sample zone (hydrodynamic pressure impulse 6000 mbars). Acetonitrile stacking is based on the forcing the sample zone out of the capillary with simultaneous application of the separation voltage. Under such conditions, the enhancing factor achieves the value 57 for peak area compared to the small sample injection length (3.2 mm, hydrodynamic pressure impulse 150 mbar.s). A fluorescence detector with a broad excitation filter (240-400 nm) and an emission filter (495 nm) was used for visualisation of the native fluorescence of perampanel. The calibration dependence of the method was linear (in the range of 10-1000 ng mL-1), with adequate accuracy (99.8-103.3 %) and precision (13.1%). LOD and LOQ for perampanel were 2.9 ng mL-1 and 9.5 ng mL-1, respectively. Clinical applicability was validated using serum samples from patients treated with perampanel and the results corresponded with reference LC-MS/MS values. Our method offers a promising alternative for determining serum perampanel with several advantages. In particular, the low quantity of serum (25 μL) required means that testing can be performed on samples obtained for monitoring other antiepileptic medications, and thus reduces the test-burden on paediatric patients.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19012451
- 003
- CZ-PrNML
- 005
- 20190412122238.0
- 007
- ta
- 008
- 190405s2018 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jpba.2018.08.006 $2 doi
- 035 __
- $a (PubMed)30121554
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Tůma, Petr $u Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00 Prague 10, Czech Republic.
- 245 10
- $a Novel electrophoretic acetonitrile-based stacking for sensitive monitoring of the antiepileptic drug perampanel in human serum / $c P. Tůma, M. Bursová, B. Sommerová, R. Horsley, R. Čabala, T. Hložek,
- 520 9_
- $a Perampanel is a novel antiepileptic drug used in paediatric patients. Existing methods that determine serum perampanel are of limited practicability. We developed a novel capillary electrophoresis (CE) method using a new version of acetonitrile stacking for on-line sample pre-concentration, and fluorescence detection (FD). CE separations were performed in a fused-silica capillary where the electroosmotic flow was reduced by coating the inner surface using a INST coating solution. The optimised background electrolyte composition was 50 mM chloroacetic acid with addition of 0.5% m/v polyvinylalcohol (pH 2.15) and separation was driven by application of positive voltage + 30 kV. Serum samples (25 μL) treated by the addition of acetonitrile in a ratio of 1:3 v/v were each injected into the capillary at a large volume that corresponded to the length (129 mm) of the sample zone (hydrodynamic pressure impulse 6000 mbars). Acetonitrile stacking is based on the forcing the sample zone out of the capillary with simultaneous application of the separation voltage. Under such conditions, the enhancing factor achieves the value 57 for peak area compared to the small sample injection length (3.2 mm, hydrodynamic pressure impulse 150 mbar.s). A fluorescence detector with a broad excitation filter (240-400 nm) and an emission filter (495 nm) was used for visualisation of the native fluorescence of perampanel. The calibration dependence of the method was linear (in the range of 10-1000 ng mL-1), with adequate accuracy (99.8-103.3 %) and precision (13.1%). LOD and LOQ for perampanel were 2.9 ng mL-1 and 9.5 ng mL-1, respectively. Clinical applicability was validated using serum samples from patients treated with perampanel and the results corresponded with reference LC-MS/MS values. Our method offers a promising alternative for determining serum perampanel with several advantages. In particular, the low quantity of serum (25 μL) required means that testing can be performed on samples obtained for monitoring other antiepileptic medications, and thus reduces the test-burden on paediatric patients.
- 650 _2
- $a acetonitrily $x chemie $7 D000097
- 650 _2
- $a antikonvulziva $7 D000927
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a monitorování léčiv $x metody $7 D016903
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a pyridony $x krev $7 D011728
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Bursová, Miroslava $u Institute of Forensic Medicine and Toxicology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Ke Karlovu 2, 121 08 Prague 2, Czech Republic; Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, 128 43 Prague 2, Czech Republic.
- 700 1_
- $a Sommerová, Blanka $u Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00 Prague 10, Czech Republic.
- 700 1_
- $a Horsley, Rachel $u National Institute of Mental Health, Topolová 748, 250 67 Klecany, Czech Republic.
- 700 1_
- $a Čabala, Radomír $u Institute of Forensic Medicine and Toxicology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Ke Karlovu 2, 121 08 Prague 2, Czech Republic; Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, 128 43 Prague 2, Czech Republic.
- 700 1_
- $a Hložek, Tomáš $u Institute of Forensic Medicine and Toxicology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Ke Karlovu 2, 121 08 Prague 2, Czech Republic; Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, 128 43 Prague 2, Czech Republic. Electronic address: tomas.hlozek@vfn.cz.
- 773 0_
- $w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 160, č. - (2018), s. 368-373
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30121554 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190405 $b ABA008
- 991 __
- $a 20190412122256 $b ABA008
- 999 __
- $a ok $b bmc $g 1391761 $s 1050756
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 160 $c - $d 368-373 $e 20180807 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
- LZP __
- $a Pubmed-20190405