• Je něco špatně v tomto záznamu ?

Improvement of Diagnostic Yield by an Additional Amplicon Module to Hybridization-Based Next-Generation Sequencing Panels

L. Obeidova, M. Urbanova, J. Stekrova, V. Elisakova, K. Hirschfeldova

. 2022 ; 24 (8) : 844-855. [pub] 20220611

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22025061

Many approaches aimed at improving next-generation sequencing output for clinical purposes exist. However, sequencing gaps or misalignments for regions that are difficult to cover because of their low complexity or high homology still exist. Our aim was to improve the yield of sequencing data. A hybridization-based next-generation sequencing library was pooled with custom add-on amplicon-based libraries processed by the same commercial test and run in parallel and sequenced simultaneously. Formulas and steps for proper amplicon pooling (250 to 7000 bp) and final library merging are presented. The novel strategy was tested on selected archetypal situations: diagnostics of a gene with many pseudogenes, a genomic region surrounded by Alu repeats, simple one-time addition of an extra gene, and mosaicism detection. The sequence of all supplemented genomic regions was traced with reasonable coverage at the background of a hybridization captured library. The flexible add-on module expands the possibilities of routine diagnostics. The technical solution makes it possible to mix amplicons that differ significantly in size and process them in one tube simultaneously with samples of the hybridization-based panel. The proposed approach reduces turnaround time and increases diagnostic yield.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22025061
003      
CZ-PrNML
005      
20221031101355.0
007      
ta
008      
221017s2022 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmoldx.2022.05.002 $2 doi
035    __
$a (PubMed)35697147
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Obeidova, Lena $u Institute of Biology and Medical Genetics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
245    10
$a Improvement of Diagnostic Yield by an Additional Amplicon Module to Hybridization-Based Next-Generation Sequencing Panels / $c L. Obeidova, M. Urbanova, J. Stekrova, V. Elisakova, K. Hirschfeldova
520    9_
$a Many approaches aimed at improving next-generation sequencing output for clinical purposes exist. However, sequencing gaps or misalignments for regions that are difficult to cover because of their low complexity or high homology still exist. Our aim was to improve the yield of sequencing data. A hybridization-based next-generation sequencing library was pooled with custom add-on amplicon-based libraries processed by the same commercial test and run in parallel and sequenced simultaneously. Formulas and steps for proper amplicon pooling (250 to 7000 bp) and final library merging are presented. The novel strategy was tested on selected archetypal situations: diagnostics of a gene with many pseudogenes, a genomic region surrounded by Alu repeats, simple one-time addition of an extra gene, and mosaicism detection. The sequence of all supplemented genomic regions was traced with reasonable coverage at the background of a hybridization captured library. The flexible add-on module expands the possibilities of routine diagnostics. The technical solution makes it possible to mix amplicons that differ significantly in size and process them in one tube simultaneously with samples of the hybridization-based panel. The proposed approach reduces turnaround time and increases diagnostic yield.
650    _2
$a genová knihovna $7 D015723
650    12
$a genomika $7 D023281
650    12
$a vysoce účinné nukleotidové sekvenování $7 D059014
650    _2
$a lidé $7 D006801
650    _2
$a hybridizace nukleových kyselin $7 D009693
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Urbanova, Marketa $u Institute of Biology and Medical Genetics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Stekrova, Jitka $u Institute of Biology and Medical Genetics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Elisakova, Veronika $u Institute of Biology and Medical Genetics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Hirschfeldova, Katerina $u Institute of Biology and Medical Genetics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. Electronic address: khirs@lf1.cuni.cz
773    0_
$w MED00012712 $t The journal of molecular diagnostics $x 1943-7811 $g Roč. 24, č. 8 (2022), s. 844-855
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35697147 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20221031101353 $b ABA008
999    __
$a ok $b bmc $g 1854659 $s 1176351
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 24 $c 8 $d 844-855 $e 20220611 $i 1943-7811 $m The Journal of molecular diagnostics $n J Mol Diagn $x MED00012712
LZP    __
$a Pubmed-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...