Percutaneous transcatheter one-step mechanical aortic disc valve prosthesis implantation: a preliminary feasibility study in swine
Sochman J, Peregrin JH, Rocek M, Timmermans HA, Pavcnik D, Rösch J
Jazyk angličtina Země Spojené státy americké
NLK
ProQuest Central
od 1997-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-02-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest)
od 1997-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 1997-01-01 do Před 1 rokem
- MeSH
- aortální insuficience chirurgie radiografie MeSH
- chirurgická náhrada chlopně metody MeSH
- financování organizované MeSH
- modely nemocí na zvířatech MeSH
- prasata MeSH
- protézy - design MeSH
- srdeční chlopně umělé MeSH
- stenty MeSH
- studie proveditelnosti MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
PURPOSE: To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. METHODS: The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z and 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. RESULTS: MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. CONCLUSION: The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07520267
- 003
- CZ-PrNML
- 005
- 20160715103816.0
- 008
- 090330s2006 xxu e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Šochman, Jan, $d 1956- $7 xx0088500
- 245 10
- $a Percutaneous transcatheter one-step mechanical aortic disc valve prosthesis implantation: a preliminary feasibility study in swine / $c Sochman J, Peregrin JH, Rocek M, Timmermans HA, Pavcnik D, Rösch J
- 314 __
- $a Intensive Care Unit, Clinic of Cardiology, Institute for Clinical and Experimental Medicine, Vídenská 1958/9, 140 21 Prague 4, Czech Republic. jan.sochman@medicon.cz
- 520 9_
- $a PURPOSE: To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. METHODS: The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z and 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. RESULTS: MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. CONCLUSION: The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aortální insuficience $x chirurgie $x radiografie $7 D001022
- 650 _2
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a srdeční chlopně umělé $7 D006350
- 650 _2
- $a chirurgická náhrada chlopně $x metody $7 D019918
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a stenty $7 D015607
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Peregrin, Jan H., $d 1951- $7 mzk2006331741
- 700 1_
- $a Roček, Miloslav, $d 1958- $7 nlk20010095509
- 700 1_
- $a Timmermans, Hans A.
- 700 1_
- $a Pavcnik, Dušan
- 700 1_
- $a Rösch, Josef, $d 1925-2016 $7 nlk19990073810
- 773 0_
- $w MED00001056 $t Cardiovascular and interventional radiology $g Roč. 29, č. 1 (2006), s. 114-119 $x 0174-1551
- 910 __
- $a ABA008 $b x $y 9 $z 0
- 990 __
- $a 20090312170439 $b ABA008
- 991 __
- $a 20160715104021 $b ABA008
- 999 __
- $a ok $b bmc $g 638070 $s 490868
- BAS __
- $a 3
- BMC __
- $a 2006 $b 29 $c 1 $d 114-119 $i 0174-1551 $m Cardiovascular and interventional radiology $x MED00001056
- LZP __
- $a 2009-B1/vtme