Automated system for release studies of salicylic acid based on a SIA method
Klimundová J, Sklenárová H, Schaefer UF, Solich P.
Language English Country Great Britain
NLK
ScienceDirect (archiv)
from 1993-01-01 to 2009-12-31
- MeSH
- Chemistry, Pharmaceutical methods instrumentation MeSH
- Financing, Organized MeSH
- Flow Injection Analysis methods instrumentation MeSH
- Salicylates analysis pharmacokinetics MeSH
The aim of this work was to describe a fully automated system for the in vitro release testing of semisolid dosage forms based on SIA technique. The system was tested for monitoring release profiles of different ointments containing 3% of salicylic acid (Belosalic, Diprosalic, Triamcinolone S). The native fluorescence of salicylic acid was used for fluorimetric detection. Phosphate buffer pH 7.4 was the receptor medium; samples were taken at 10 min intervals during 6 h of the release test; and each test was followed by calibration with five standard solutions. The linear calibration range was 0.05-10 microg ml(-1) (r = 0.9996, six standards); the maximal SIA sample throughput for this system was 120 h(-1), sample volume being 50 microl and flow rate 50 microl s(-1). The detection limit for salicylic acid was 0.01 microg ml(-1).
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07520419
- 003
- CZ-PrNML
- 005
- 20130129170830.0
- 008
- 090401s2005 xxk e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Klimundová, Jana $7 xx0128598
- 245 10
- $a Automated system for release studies of salicylic acid based on a SIA method / $c Klimundová J, Sklenárová H, Schaefer UF, Solich P.
- 314 __
- $a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 50005, Czech Republic
- 520 9_
- $a The aim of this work was to describe a fully automated system for the in vitro release testing of semisolid dosage forms based on SIA technique. The system was tested for monitoring release profiles of different ointments containing 3% of salicylic acid (Belosalic, Diprosalic, Triamcinolone S). The native fluorescence of salicylic acid was used for fluorimetric detection. Phosphate buffer pH 7.4 was the receptor medium; samples were taken at 10 min intervals during 6 h of the release test; and each test was followed by calibration with five standard solutions. The linear calibration range was 0.05-10 microg ml(-1) (r = 0.9996, six standards); the maximal SIA sample throughput for this system was 120 h(-1), sample volume being 50 microl and flow rate 50 microl s(-1). The detection limit for salicylic acid was 0.01 microg ml(-1).
- 650 _2
- $a farmaceutická chemie $x metody $x přístrojové vybavení $7 D002626
- 650 _2
- $a průtoková injekční analýza $x metody $x přístrojové vybavení $7 D017022
- 650 _2
- $a salicylany $x analýza $x farmakokinetika $7 D012459
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Sklenářová, Hana $7 xx0128833
- 700 1_
- $a Schaefer, U. F.
- 700 1_
- $a Solich, Petr, $d 1955- $7 jo2007285395
- 773 0_
- $w MED00002894 $t Journal of pharmaceutical and biomedical analysis $g Roč. 37, č. 5 (2005), s. 893-898 $x 0731-7085
- 910 __
- $a ABA008 $b x $y 9
- 990 __
- $a 20090310084605 $b ABA008
- 991 __
- $a 20090716094223 $b ABA008
- 999 __
- $a ok $b bmc $g 638222 $s 491021
- BAS __
- $a 3
- BMC __
- $a 2005 $b 37 $c 5 $d 893-898 $i 0731-7085 $m Journal of pharmaceutical and biomedical analysis $x MED00002894
- LZP __
- $a 2009-B2/ipme