Automated system for release studies of salicylic acid based on a SIA method

Klimundová J, Sklenárová H, Schaefer UF, Solich P.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc07520419
E-zdroje Online

NLK ScienceDirect (archiv) od 1993-01-01 do 2009-12-31

The aim of this work was to describe a fully automated system for the in vitro release testing of semisolid dosage forms based on SIA technique. The system was tested for monitoring release profiles of different ointments containing 3% of salicylic acid (Belosalic, Diprosalic, Triamcinolone S). The native fluorescence of salicylic acid was used for fluorimetric detection. Phosphate buffer pH 7.4 was the receptor medium; samples were taken at 10 min intervals during 6 h of the release test; and each test was followed by calibration with five standard solutions. The linear calibration range was 0.05-10 microg ml(-1) (r = 0.9996, six standards); the maximal SIA sample throughput for this system was 120 h(-1), sample volume being 50 microl and flow rate 50 microl s(-1). The detection limit for salicylic acid was 0.01 microg ml(-1).

000      
00000naa 2200000 a 4500
001      
bmc07520419
003      
CZ-PrNML
005      
20130129170830.0
008      
090401s2005 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Klimundová, Jana $7 xx0128598
245    10
$a Automated system for release studies of salicylic acid based on a SIA method / $c Klimundová J, Sklenárová H, Schaefer UF, Solich P.
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 50005, Czech Republic
520    9_
$a The aim of this work was to describe a fully automated system for the in vitro release testing of semisolid dosage forms based on SIA technique. The system was tested for monitoring release profiles of different ointments containing 3% of salicylic acid (Belosalic, Diprosalic, Triamcinolone S). The native fluorescence of salicylic acid was used for fluorimetric detection. Phosphate buffer pH 7.4 was the receptor medium; samples were taken at 10 min intervals during 6 h of the release test; and each test was followed by calibration with five standard solutions. The linear calibration range was 0.05-10 microg ml(-1) (r = 0.9996, six standards); the maximal SIA sample throughput for this system was 120 h(-1), sample volume being 50 microl and flow rate 50 microl s(-1). The detection limit for salicylic acid was 0.01 microg ml(-1).
650    _2
$a farmaceutická chemie $x metody $x přístrojové vybavení $7 D002626
650    _2
$a průtoková injekční analýza $x metody $x přístrojové vybavení $7 D017022
650    _2
$a salicylany $x analýza $x farmakokinetika $7 D012459
650    _2
$a financování organizované $7 D005381
700    1_
$a Sklenářová, Hana $7 xx0128833
700    1_
$a Schaefer, U. F.
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $g Roč. 37, č. 5 (2005), s. 893-898 $x 0731-7085
910    __
$a ABA008 $b x $y 9
990    __
$a 20090310084605 $b ABA008
991    __
$a 20090716094223 $b ABA008
999    __
$a ok $b bmc $g 638222 $s 491021
BAS    __
$a 3
BMC    __
$a 2005 $b 37 $c 5 $d 893-898 $i 0731-7085 $m Journal of pharmaceutical and biomedical analysis $x MED00002894
LZP    __
$a 2009-B2/ipme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...