-
Je něco špatně v tomto záznamu ?
Riziko náhlé smrti s časnou repolarizací
[Sudden cardiac arrest associated with early repolarization]
Michael Haissaguerre, et al.
Jazyk čeština Země Česko
- MeSH
- antiarytmika terapeutické užití MeSH
- defibrilátory implantabilní MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- fibrilace komor komplikace patofyziologie terapie MeSH
- katetrizační ablace MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt etiologie MeSH
- následné studie MeSH
- neparametrická statistika MeSH
- pojišťovací analýza MeSH
- prevalence MeSH
- recidiva MeSH
- srdeční arytmie epidemiologie MeSH
- srdeční elektrofyziologie MeSH
- studie případů a kontrol MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
Early repolarization is a common electrocardiographic finding that is generally considered to be benign. Its potential to cause cardiac arrhythmias has been hypothesized from experimental studies, but it is not known whether there is a clinical association with sudden cardiac arrest. METHODS: We reviewed data from 206 case subjects at 22 centers who were resuscitated after cardiac arrest due to idiopathic ventricular fibrillation and assessed the prevalence of electrocardiographic early repolarization. The latter was defined as an elevation of the QRS-ST junction of at least 0.1 mV from baseline in the inferior or lateral lead, manifested as QRS slurring or notching. The control group comprised 412 subjects without heart disease who were matched for age, sex, race, and level of physical activity. Follow-up data that included the results of monitoring with an implantable defibrillator were obtained for all case subjects. RESULTS: Early repolarization was more frequent in case subjects with idiopathic ventricular fibrillation than in control subjects (31% vs. 5%, P<0.001). Among case subjects, those with early repolarization were more likely to be male and to have a history of syncope or sudden cardiac arrest during sleep than those without early repolarization. In eight subjects, the origin of ectopy that initiated ventricular arrhythmias was mapped to sites concordant with the localization of repolarization abnormalities. During a mean (+/-SD) follow-up of 61+/-50 months, defibrillator monitoring showed a higher incidence of recurrent ventricular fibrillation in case subjects with a repolarization abnormality than in those without such an abnormality (hazard ratio, 2.1; 95% confidence interval, 1.2 to 3.5; P=0.008). CONCLUSIONS: Among patients with a history of idiopathic ventricular fibrillation, there is an increased prevalence of early repolarization. Copyright 2008 Massachusetts Medical Society.
Sudden cardiac arrest associated with early repolarization
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07521981
- 003
- CZ-PrNML
- 005
- 20111210133041.0
- 008
- 090423s2008 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Haissaguerre, Michael
- 245 10
- $a Riziko náhlé smrti s časnou repolarizací / $c Michael Haissaguerre, et al.
- 246 11
- $a Sudden cardiac arrest associated with early repolarization
- 314 __
- $a Université Bordeaux, Hôpital Haut-Léveque, Bordeaux-Pessac, Bordeaux
- 520 9_
- $a Early repolarization is a common electrocardiographic finding that is generally considered to be benign. Its potential to cause cardiac arrhythmias has been hypothesized from experimental studies, but it is not known whether there is a clinical association with sudden cardiac arrest. METHODS: We reviewed data from 206 case subjects at 22 centers who were resuscitated after cardiac arrest due to idiopathic ventricular fibrillation and assessed the prevalence of electrocardiographic early repolarization. The latter was defined as an elevation of the QRS-ST junction of at least 0.1 mV from baseline in the inferior or lateral lead, manifested as QRS slurring or notching. The control group comprised 412 subjects without heart disease who were matched for age, sex, race, and level of physical activity. Follow-up data that included the results of monitoring with an implantable defibrillator were obtained for all case subjects. RESULTS: Early repolarization was more frequent in case subjects with idiopathic ventricular fibrillation than in control subjects (31% vs. 5%, P<0.001). Among case subjects, those with early repolarization were more likely to be male and to have a history of syncope or sudden cardiac arrest during sleep than those without early repolarization. In eight subjects, the origin of ectopy that initiated ventricular arrhythmias was mapped to sites concordant with the localization of repolarization abnormalities. During a mean (+/-SD) follow-up of 61+/-50 months, defibrillator monitoring showed a higher incidence of recurrent ventricular fibrillation in case subjects with a repolarization abnormality than in those without such an abnormality (hazard ratio, 2.1; 95% confidence interval, 1.2 to 3.5; P=0.008). CONCLUSIONS: Among patients with a history of idiopathic ventricular fibrillation, there is an increased prevalence of early repolarization. Copyright 2008 Massachusetts Medical Society.
- 650 _2
- $a pojišťovací analýza $7 D000206
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a antiarytmika $x terapeutické užití $7 D000889
- 650 _2
- $a srdeční arytmie $x epidemiologie $7 D001145
- 650 _2
- $a srdeční elektrofyziologie $7 D054849
- 650 _2
- $a studie případů a kontrol $7 D016022
- 650 _2
- $a katetrizační ablace $7 D017115
- 650 _2
- $a náhlá srdeční smrt $x etiologie $7 D016757
- 650 _2
- $a defibrilátory implantabilní $7 D017147
- 650 _2
- $a elektrokardiografie $7 D004562
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a následné studie $7 D005500
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a prevalence $7 D015995
- 650 _2
- $a recidiva $7 D012008
- 650 _2
- $a neparametrická statistika $7 D018709
- 650 _2
- $a fibrilace komor $x komplikace $x patofyziologie $x terapie $7 D014693
- 773 0_
- $w MED00012706 $t Clinical cardiology alert $g Roč. 2, č. 5 (2008), s. 37 $x 1213-2586
- 787 18
- $w bmc07521982 $i Recenze v: $t Komentář [k článku Riziko náhlé smrti s časnou repolarizací]
- 910 __
- $a ABA008 $b B 2242 $c 407 a $y 9
- 990 __
- $a 20090423080915 $b ABA008
- 991 __
- $a 20090601112139 $b ABA008
- 999 __
- $a ok $b bmc $g 645070 $s 497986
- BAS __
- $a 3
- BMC __
- $a 2008 $b 2 $c 5 $d 37 $i 1213-2586 $m Clinical Cardiology Alert $x MED00012706
- LZP __
- $a 2009-15/mkme