Development of a stacking-CZE method for the analysis of phenolic acids

Šafra J., Pospíšilová M., Kavalírová A.

. 2006 ; 41 (3) : 1022-1024.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc07523543

Grantová podpora
NL7689 MZ0 CEP - Centrální evidence projektů

Digitální knihovna NLK
Plný text - Část
Zdroj

E-zdroje Online

NLK ScienceDirect (archiv) od 1993-01-01 do 2009-12-31

Eight phenolic acids were analyzed by capillary zone electrophoresis. On-line analyte preconcentration was carried out by hydrodynamic injection of large volume of sample followed by removal of the bulk of the low conductivity sample matrix by polarity switching. The optimal electrolyte system consisted of 50mM sodium tetraborate of pH 9.0 (adjusted with 0.1 M phosphoric acid) containing 2% of alpha-cyclodextrin. The separations were carried out with a fused silica capillary (effective length 50 cm, i.d. 50 microm) and monitored at 200 nm. Under optimized preconcentration conditions (sample injection 99 s at 100 mbar and the polarity switching time 1.0 min) linear calibration ranges (0.1-2.0 microg/ml, R=0.9979-0.9995), favourable limits of detection (0.01-0.025 microg/ml) and good repeatability of the peak areas (R.S.D.: 2.76-5.69%, n=6) were achieved.

000      
00000naa 2200000 a 4500
001      
bmc07523543
003      
CZ-PrNML
005      
20130326085709.0
008      
090520s2006 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Šafra, Jiří, $d 1981- $7 xx0259160
245    10
$a Development of a stacking-CZE method for the analysis of phenolic acids / $c Šafra J., Pospíšilová M., Kavalírová A.
314    __
$a Charles University in Prague, Pharmaceutical Faculty in Hradec Králové, Department of Analytical Chemistry, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. jiri.safra@faf.cuni.cz
520    9_
$a Eight phenolic acids were analyzed by capillary zone electrophoresis. On-line analyte preconcentration was carried out by hydrodynamic injection of large volume of sample followed by removal of the bulk of the low conductivity sample matrix by polarity switching. The optimal electrolyte system consisted of 50mM sodium tetraborate of pH 9.0 (adjusted with 0.1 M phosphoric acid) containing 2% of alpha-cyclodextrin. The separations were carried out with a fused silica capillary (effective length 50 cm, i.d. 50 microm) and monitored at 200 nm. Under optimized preconcentration conditions (sample injection 99 s at 100 mbar and the polarity switching time 1.0 min) linear calibration ranges (0.1-2.0 microg/ml, R=0.9979-0.9995), favourable limits of detection (0.01-0.025 microg/ml) and good repeatability of the peak areas (R.S.D.: 2.76-5.69%, n=6) were achieved.
650    _2
$a financování organizované $7 D005381
650    _2
$a kalibrace $7 D002138
650    _2
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a hydroxybenzoáty $x analýza $7 D062385
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a alfa-cyklodextriny $x chemie $7 D047391
700    1_
$a Pospíšilová, Marie, $d 1946- $7 xx0063894
700    1_
$a Kavalírová, Andrea $7 xx0127938
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $g Roč. 41, č. 3 (2006), s. 1022-1024 $x 0731-7085
910    __
$a ABA008 $b x $y 9
990    __
$a 20090506084234 $b ABA008
991    __
$a 20130326085931 $b ABA008
999    __
$a ok $b bmc $g 655581 $s 508891
BAS    __
$a 3
BMC    __
$a 2006 $b 41 $c 3 $d 1022-1024 $i 0731-7085 $m Journal of pharmaceutical and biomedical analysis $x MED00002894
GRA    __
$a NL7689 $p MZ0
LZP    __
$a 2009-B2/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...