The quality of dental radiography in the Czech Republic--results of a TLD and film postal audit

Novák L

. 2006 ; 120 (1-4) : 155-158.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc07523761
E-zdroje Online

NLK Medline Complete (EBSCOhost) od 1996-01-01 do Před 1 rokem

Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Conversely, the audit gives better information about the patient examination practices. During the period of January 2002 to May 2004 approximately 4000 audits were performed. The results confirmed that main problems in dental radiography are due to incorrect film processing, non-optimised setting of the exposure parameters and use of obsolete X-ray machines. Only approximately 30% of performed audits were satisfactory with respect to all checked parameters.

000      
00000naa 2200000 a 4500
001      
bmc07523761
003      
CZ-PrNML
005      
20111210140035.0
008      
090525s2006 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Novák, Leoš $7 xx0079088
245    14
$a The quality of dental radiography in the Czech Republic--results of a TLD and film postal audit / $c Novák L
314    __
$a National Radiation Protection Institute (NRPI), Srobárova 48, 100 00 Prague 10, Czech Republic. leos.novak@suro.cz
520    9_
$a Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Conversely, the audit gives better information about the patient examination practices. During the period of January 2002 to May 2004 approximately 4000 audits were performed. The results confirmed that main problems in dental radiography are due to incorrect film processing, non-optimised setting of the exposure parameters and use of obsolete X-ray machines. Only approximately 30% of performed audits were satisfactory with respect to all checked parameters.
650    _2
$a dentální audit $7 D019230
650    _2
$a filmová dozimetrie $x normy $x statistika a číselné údaje $7 D005373
650    _2
$a lékařská praxe - způsoby provádění $x normy $x statistika a číselné údaje $7 D010818
650    _2
$a směrnice pro lékařskou praxi jako téma $7 D017410
650    _2
$a zajištění kvality zdravotní péče $7 D011785
650    _2
$a průzkumy a dotazníky $7 D011795
650    _2
$a rentgendiagnostika zubní $x normy $x statistika a číselné údaje $7 D011861
650    _2
$a termoluminiscenční dozimetrie $x normy $x statistika a číselné údaje $7 D013819
651    _2
$a Česká republika $7 D018153
773    0_
$w MED00004029 $t Radiation protection dosimetry $g Roč. 120, č. 1-4 (2006), s. 155-158 $x 0144-8420
910    __
$a ABA008 $b x $y 9
990    __
$a 20090519102933 $b ABA008
991    __
$a 20090909084411 $b ABA008
999    __
$a ok $b bmc $g 656835 $s 510155
BAS    __
$a 3
BMC    __
$a 2006 $b 120 $c 1-4 $d 155-158 $i 0144-8420 $m Radiation protection dosimetry $x MED00004029
LZP    __
$a 2009-B2/dkme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...