-
Je něco špatně v tomto záznamu ?
The quality of dental radiography in the Czech Republic--results of a TLD and film postal audit
Novák L
Jazyk angličtina Země Velká Británie
NLK
Medline Complete (EBSCOhost)
od 1996-01-01 do Před 1 rokem
- MeSH
- dentální audit MeSH
- filmová dozimetrie normy statistika a číselné údaje MeSH
- lékařská praxe - způsoby provádění normy statistika a číselné údaje MeSH
- průzkumy a dotazníky MeSH
- rentgendiagnostika zubní normy statistika a číselné údaje MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- termoluminiscenční dozimetrie normy statistika a číselné údaje MeSH
- zajištění kvality zdravotní péče MeSH
- Geografické názvy
- Česká republika MeSH
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Conversely, the audit gives better information about the patient examination practices. During the period of January 2002 to May 2004 approximately 4000 audits were performed. The results confirmed that main problems in dental radiography are due to incorrect film processing, non-optimised setting of the exposure parameters and use of obsolete X-ray machines. Only approximately 30% of performed audits were satisfactory with respect to all checked parameters.
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07523761
- 003
- CZ-PrNML
- 005
- 20111210140035.0
- 008
- 090525s2006 xxk e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Novák, Leoš $7 xx0079088
- 245 14
- $a The quality of dental radiography in the Czech Republic--results of a TLD and film postal audit / $c Novák L
- 314 __
- $a National Radiation Protection Institute (NRPI), Srobárova 48, 100 00 Prague 10, Czech Republic. leos.novak@suro.cz
- 520 9_
- $a Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Conversely, the audit gives better information about the patient examination practices. During the period of January 2002 to May 2004 approximately 4000 audits were performed. The results confirmed that main problems in dental radiography are due to incorrect film processing, non-optimised setting of the exposure parameters and use of obsolete X-ray machines. Only approximately 30% of performed audits were satisfactory with respect to all checked parameters.
- 650 _2
- $a dentální audit $7 D019230
- 650 _2
- $a filmová dozimetrie $x normy $x statistika a číselné údaje $7 D005373
- 650 _2
- $a lékařská praxe - způsoby provádění $x normy $x statistika a číselné údaje $7 D010818
- 650 _2
- $a směrnice pro lékařskou praxi jako téma $7 D017410
- 650 _2
- $a zajištění kvality zdravotní péče $7 D011785
- 650 _2
- $a průzkumy a dotazníky $7 D011795
- 650 _2
- $a rentgendiagnostika zubní $x normy $x statistika a číselné údaje $7 D011861
- 650 _2
- $a termoluminiscenční dozimetrie $x normy $x statistika a číselné údaje $7 D013819
- 651 _2
- $a Česká republika $7 D018153
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $g Roč. 120, č. 1-4 (2006), s. 155-158 $x 0144-8420
- 910 __
- $a ABA008 $b x $y 9
- 990 __
- $a 20090519102933 $b ABA008
- 991 __
- $a 20090909084411 $b ABA008
- 999 __
- $a ok $b bmc $g 656835 $s 510155
- BAS __
- $a 3
- BMC __
- $a 2006 $b 120 $c 1-4 $d 155-158 $i 0144-8420 $m Radiation protection dosimetry $x MED00004029
- LZP __
- $a 2009-B2/dkme