Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Atlantoaxial fixation using the polyaxial screw-rod system

Stulik J, Vyskocil T, Sebesta P, Kryl J

. 2007 ; 16 (4) : 479-484.

Jazyk angličtina Země Německo

Typ dokumentu klinické zkoušky

Perzistentní odkaz   https://www.medvik.cz/link/bmc07526833
E-zdroje Online

NLK Free Medical Journals od 1997 do 2014
PubMed Central od 1997 do 2014
Europe PubMed Central od 1997 do 2014
ProQuest Central od 1997-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2000-02-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-01-01 do Před 1 rokem

The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw-rod system. Twenty-eight patients followed-up 12-29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23-89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1-C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1-C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1-C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.

000      
00000naa 2200000 a 4500
001      
bmc07526833
003      
CZ-PrNML
005      
20111210143457.0
008      
090801s2007 gw e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Štulík, Jan, $d 1967- $7 nlk20030127573
245    10
$a Atlantoaxial fixation using the polyaxial screw-rod system / $c Stulik J, Vyskocil T, Sebesta P, Kryl J
314    __
$a Spine Surgery Department, Teaching Hospital Prague Motol, Prague 5, Czech Republic. janstulik.spine@seznam.cz
520    9_
$a The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw-rod system. Twenty-eight patients followed-up 12-29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23-89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1-C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1-C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1-C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a atlantoaxiální kloub $x chirurgie $7 D001268
650    _2
$a kostní hřeby $7 D001858
650    _2
$a kostní šrouby $7 D001863
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a následné studie $7 D005500
650    _2
$a lidé $7 D006801
650    _2
$a nestabilita kloubu $x chirurgie $7 D007593
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a dens axis $x chirurgie $x zranění $7 D009809
650    _2
$a osteoartróza $x chirurgie $7 D010003
650    _2
$a fraktury páteře $x chirurgie $7 D016103
650    _2
$a fúze páteře $x metody $x přístrojové vybavení $7 D013123
655    _2
$a klinické zkoušky $7 D016430
700    1_
$a Vyskočil, Tomáš, $d 1974- $7 xx0093691
700    1_
$a Šebesta, Petr $7 xx0062741
700    1_
$a Kryl, Jan $7 xx0093692
773    0_
$w MED00001666 $t European spine journal $g Roč. 16, č. 4 (2007), s. 479-484 $x 0940-6719
910    __
$a ABA008 $b x $y 7
990    __
$a 20090726182400 $b ABA008
991    __
$a 20090924151348 $b ABA008
999    __
$a ok $b bmc $g 670849 $s 529998
BAS    __
$a 3
BMC    __
$a 2007 $b 16 $c 4 $d 479-484 $i 0940-6719 $m European spine journal $x MED00001666
LZP    __
$a 2009-B3/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...