Potentiometric sensor for heparin polyion: transient behavior and response mechanism

Langmaier J, Samcova E, Samec Z

. 2007 ; 79 (7) : 2892-2900.

Jazyk angličtina Země Spojené státy americké

Perzistentní odkaz   https://www.medvik.cz/link/bmc07527101

Chronopotentiometry and electrochemical impedance spectroscopy were used to study the transient behavior and the potentiometric response mechanism of the polymer membrane-based sensor for heparin. Membrane with a composition of 66 wt % poly(vinyl chloride), 33 wt % o-nitrophenyl octyl ether (plasticizer), and 0.05 M tridodecylmethylammonium chloride (ion exchanger) was deposited on the surface of a silver or a glassy carbon (GC) electrode. In the latter case, the membrane contained also 0.1 M 1,1'-dimethylferrocene/1,1'-dimethylferricenium+ couple ensuring the electronic contact between the membrane and GC. The sensor was dipped in an aqueous solution of 0.1 M LiCl, which was stirred with a magnetic stirrer (2-18.2 Hz), and eventually spiked with heparin (0.05-5 U mL-1). Chronopotentiometric measurements were carried out using either the Ag supported membrane with a thickness>100 microm or the GC supported membrane with a defined thickness of 2-30 microm, which was also used in impedance measurements. Remarkable features of the potentiometric response include the linear dependence of the initial slope of the potential transient on the heparin concentration in the aqueous phase and on the square root of the stirring frequency, and the absence of the effect of the membrane thickness. Impedance measurements (0.1 Hz-10 kHz) made it possible to identify and to evaluate the geometric capacitance and the capacitance of the electric double layer at the membrane/solution interface, the bulk membrane and charge-transfer resistances, and the Warburg impedance of the chloride transport. Changes in the membrane bulk and charge-transfer resistances and the Warburg impedance upon spiking the aqueous solution with heparin were found to be consistent with the steady-state response of approximately -25 mV, indicating that the bulk chloride concentration in the membrane decreased to about half of its initial value. A novel theoretical model of the transient behavior was developed based on the balance of the charging and the faradic currents of chloride and heparin, in accordance with the ion-exchange mechanism that has been proposed previously. It was concluded that the initial slope of the potential transient is linked to the charging of the double layer coupled to the chloride ion transfer across the membrane/solution interface and to the diffusion-limited transport of heparin in the solution. The potentiometric assay of heparin could be based on measurements of the initial slope of the potential transient or the potential at a fixed time shortly after the heparin injection.

000      
00000naa 2200000 a 4500
001      
bmc07527101
003      
CZ-PrNML
005      
20111210143546.0
008      
090810s2007 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Langmaier, Jan. $7 _AN035471
245    10
$a Potentiometric sensor for heparin polyion: transient behavior and response mechanism / $c Langmaier J, Samcova E, Samec Z
314    __
$a J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejskova 3, 182 23 Prague 8, Czech Republic
520    9_
$a Chronopotentiometry and electrochemical impedance spectroscopy were used to study the transient behavior and the potentiometric response mechanism of the polymer membrane-based sensor for heparin. Membrane with a composition of 66 wt % poly(vinyl chloride), 33 wt % o-nitrophenyl octyl ether (plasticizer), and 0.05 M tridodecylmethylammonium chloride (ion exchanger) was deposited on the surface of a silver or a glassy carbon (GC) electrode. In the latter case, the membrane contained also 0.1 M 1,1'-dimethylferrocene/1,1'-dimethylferricenium+ couple ensuring the electronic contact between the membrane and GC. The sensor was dipped in an aqueous solution of 0.1 M LiCl, which was stirred with a magnetic stirrer (2-18.2 Hz), and eventually spiked with heparin (0.05-5 U mL-1). Chronopotentiometric measurements were carried out using either the Ag supported membrane with a thickness>100 microm or the GC supported membrane with a defined thickness of 2-30 microm, which was also used in impedance measurements. Remarkable features of the potentiometric response include the linear dependence of the initial slope of the potential transient on the heparin concentration in the aqueous phase and on the square root of the stirring frequency, and the absence of the effect of the membrane thickness. Impedance measurements (0.1 Hz-10 kHz) made it possible to identify and to evaluate the geometric capacitance and the capacitance of the electric double layer at the membrane/solution interface, the bulk membrane and charge-transfer resistances, and the Warburg impedance of the chloride transport. Changes in the membrane bulk and charge-transfer resistances and the Warburg impedance upon spiking the aqueous solution with heparin were found to be consistent with the steady-state response of approximately -25 mV, indicating that the bulk chloride concentration in the membrane decreased to about half of its initial value. A novel theoretical model of the transient behavior was developed based on the balance of the charging and the faradic currents of chloride and heparin, in accordance with the ion-exchange mechanism that has been proposed previously. It was concluded that the initial slope of the potential transient is linked to the charging of the double layer coupled to the chloride ion transfer across the membrane/solution interface and to the diffusion-limited transport of heparin in the solution. The potentiometric assay of heparin could be based on measurements of the initial slope of the potential transient or the potential at a fixed time shortly after the heparin injection.
650    _2
$a financování organizované $7 D005381
650    _2
$a uhlík $x chemie $7 D002244
650    _2
$a elektrochemie $7 D004563
650    _2
$a elektrody $7 D004566
650    _2
$a ethery $x chemie $7 D004987
650    _2
$a heparin $x analýza $x chemie $7 D006493
650    _2
$a ionty $x chemie $7 D007477
650    _2
$a membrány umělé $7 D008567
650    _2
$a polyvinylchlorid $x chemie $7 D011143
650    _2
$a potenciometrie $7 D011199
650    _2
$a kvartérní amoniové sloučeniny $x chemie $7 D000644
650    _2
$a stříbro $x chemie $7 D012834
700    1_
$a Samcová, Eva, $d 1947- $7 nlk19990073817
700    1_
$a Samec, Zdeněk, $d 1947- $7 jn20000710493
773    0_
$w MED00000337 $t Analytical chemistry $g Roč. 79, č. 7 (2007), s. 2892-2900 $x 0003-2700
910    __
$a ABA008 $b x $y 7
990    __
$a 20090726182400 $b ABA008
991    __
$a 20090923160004 $b ABA008
999    __
$a ok $b bmc $g 671095 $s 530268
BAS    __
$a 3
BMC    __
$a 2007 $b 79 $c 7 $d 2892-2900 $i 0003-2700 $m Analytical chemistry $x MED00000337
LZP    __
$a 2009-B3/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...