The cardiovascular response to lower body negative pressure in humans depends on seal location

N. Goswami, E. Grasser, A. Roessler, D. Schneditz, H. Hinghofer-Szalkay

. 2009 ; 58 (3) : 311-318.

Language English Country Czech Republic

Document type Comparative Study

We tested whether seal location at iliac crest (IC) or upper abdomen (UA), before and during lower body negative pressure (LBNP), would affect thoracic electrical impedance, hepatic blood flow, and central cardiovascular responses to LBNP. After 30 min of supine rest, LBNP at -40 mm Hg was applied for 15 min, either at IC or UA, in 14 healthy males. Plasma density and indocyanine green concentrations assessed plasma volume changes and hepatic perfusion. With both sealing types, LBNP-induced effects remained unchanged for mean arterial pressure (-3.0+/-1.1 mm Hg), cardiac output (-1.0 l min(-1)), and plasma volume (-11 %). Heart rate was greater during UA (80.6+/-3.3 bpm) than IC (76.0+/-2.5 bpm) (p<0.01) and thoracic impedance increased more using UA (3.2+/-0.2 Omega) than IC (1.8+/-0.2 Omega) (p<0.0001). Furthermore, during supine rest, UA was accompanied by lower thoracic impedance (26.9+/-1.1 vs 29.0+/-0.8 Omega, p<0.001) and hepatic perfusion (1.6 vs 1.8 l.min(-1), p<0.05) compared to IC. The data suggest that the reduction in central blood volume in response to LBNP depends on location of the applied seal. The sealing in itself altered blood volume distribution and hepatic perfusion in supine resting humans. Finally, application of LBNP with the seal at the upper abdomen induced a markedly larger reduction in central blood volume and greater increases in heart rate than when the seal was located at the iliac crest.

References provided by Crossref.org

Bibliography, etc.

Lit.: 41

000      
00000naa 2200000 a 4500
001      
bmc07530804
003      
CZ-PrNML
005      
20111210151812.0
008      
091013s2009 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.931431 $2 doi
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Goswami, N.
245    14
$a The cardiovascular response to lower body negative pressure in humans depends on seal location / $c N. Goswami, E. Grasser, A. Roessler, D. Schneditz, H. Hinghofer-Szalkay
314    __
$a Institute of Physiology, Center for Physiological Medicine, Medical University of Graz, Graz
504    __
$a Lit.: 41
520    9_
$a We tested whether seal location at iliac crest (IC) or upper abdomen (UA), before and during lower body negative pressure (LBNP), would affect thoracic electrical impedance, hepatic blood flow, and central cardiovascular responses to LBNP. After 30 min of supine rest, LBNP at -40 mm Hg was applied for 15 min, either at IC or UA, in 14 healthy males. Plasma density and indocyanine green concentrations assessed plasma volume changes and hepatic perfusion. With both sealing types, LBNP-induced effects remained unchanged for mean arterial pressure (-3.0+/-1.1 mm Hg), cardiac output (-1.0 l min(-1)), and plasma volume (-11 %). Heart rate was greater during UA (80.6+/-3.3 bpm) than IC (76.0+/-2.5 bpm) (p<0.01) and thoracic impedance increased more using UA (3.2+/-0.2 Omega) than IC (1.8+/-0.2 Omega) (p<0.0001). Furthermore, during supine rest, UA was accompanied by lower thoracic impedance (26.9+/-1.1 vs 29.0+/-0.8 Omega, p<0.001) and hepatic perfusion (1.6 vs 1.8 l.min(-1), p<0.05) compared to IC. The data suggest that the reduction in central blood volume in response to LBNP depends on location of the applied seal. The sealing in itself altered blood volume distribution and hepatic perfusion in supine resting humans. Finally, application of LBNP with the seal at the upper abdomen induced a markedly larger reduction in central blood volume and greater increases in heart rate than when the seal was located at the iliac crest.
650    _2
$a financování organizované $7 D005381
650    _2
$a dospělí $7 D000328
650    _2
$a krevní tlak $7 D001794
650    _2
$a minutový srdeční výdej $7 D002302
650    _2
$a kardiovaskulární fyziologické jevy $7 D002320
650    _2
$a elektrická impedance $7 D017097
650    _2
$a přesuny tekutin $7 D018495
650    _2
$a srdeční frekvence $7 D006339
650    _2
$a lidé $7 D006801
650    _2
$a jaterní oběh $7 D008102
650    _2
$a abdominální dekomprese $x metody $7 D008150
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a objem plazmy $7 D010953
650    _2
$a supinační poloha $7 D016683
650    _2
$a mladý dospělý $7 D055815
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Grasser, E.
700    1_
$a Roessler, A.
700    1_
$a Schneditz, D.
700    1_
$a Hinghofer-Szalkay, H.
773    0_
$w MED00003824 $t Physiological research $g Roč. 58, č. 3 (2009), s. 311-318 $x 0862-8408
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/58/58_311.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 9
990    __
$a 20091009100046 $b ABA008
991    __
$a 20091013132545 $b ABA008
999    __
$a ok $b bmc $g 689330 $s 551172
BAS    __
$a 3
BMC    __
$a 2009 $b 58 $c 3 $d 311-318 $i 0862-8408 $m Physiological research $x MED00003824
LZP    __
$a 2009-32/mkme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...