Something wrong with this record ?
Results on the evaluation of an embedded fall sensor
J. Poujaud, N. Noury, and J.-E. Lundy
Language English Country Czech Republic
- MeSH
- Algorithms MeSH
- Monitoring, Ambulatory methods instrumentation utilization MeSH
- Biomedical Engineering methods instrumentation MeSH
- Electrical Equipment and Supplies MeSH
- Human Experimentation MeSH
- Frail Elderly psychology statistics & numerical data MeSH
- Electronics, Medical methods instrumentation MeSH
- Humans MeSH
- Signal Processing, Computer-Assisted MeSH
- Movement Disorders complications rehabilitation MeSH
- Aged MeSH
- Sensitivity and Specificity MeSH
- Equipment and Supplies MeSH
- Check Tag
- Humans MeSH
- Aged MeSH
The fall of elderly people is an important public health problem. Fall has physical, but also psychological consequences. For years, many researches were carried out in this fi eld by Scientists of all around the world. Some prototypes provided reliable results but most of them are not yet wearable devices and, further more, not scalable. An embedded fall sensor was developed by TIMC-IMAG laboratory. It is now at the stage of industrialisation. In this paper we will focus on the evaluation of this fall sensor with 14 healthy volunteers on our experimental “fall” platform. We also will describe our original method to determine the reliability of a fall sensor.
The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
Bibliography, etc.Lit.: 14
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531318
- 003
- CZ-PrNML
- 005
- 20111210152029.0
- 008
- 091017s2008 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Poujaud, Julien
- 245 10
- $a Results on the evaluation of an embedded fall sensor / $c J. Poujaud, N. Noury, and J.-E. Lundy
- 314 __
- $a TIMC-IMAG Laboratory, Grenoble, France
- 500 __
- $a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
- 504 __
- $a Lit.: 14
- 520 9_
- $a The fall of elderly people is an important public health problem. Fall has physical, but also psychological consequences. For years, many researches were carried out in this fi eld by Scientists of all around the world. Some prototypes provided reliable results but most of them are not yet wearable devices and, further more, not scalable. An embedded fall sensor was developed by TIMC-IMAG laboratory. It is now at the stage of industrialisation. In this paper we will focus on the evaluation of this fall sensor with 14 healthy volunteers on our experimental “fall” platform. We also will describe our original method to determine the reliability of a fall sensor.
- 650 _2
- $a křehký senior $x psychologie $x statistika a číselné údaje $7 D016330
- 650 _2
- $a pohybové poruchy $x komplikace $x rehabilitace $7 D009069
- 650 _2
- $a ambulantní monitorování $x metody $x přístrojové vybavení $x využití $7 D018670
- 650 _2
- $a biomedicínské inženýrství $x metody $x přístrojové vybavení $7 D001698
- 650 _2
- $a lékařská elektronika $x metody $x přístrojové vybavení $7 D004582
- 650 _2
- $a zdravotnické prostředky $7 D004864
- 650 _2
- $a elektrické vybavení a zdroje $7 D055615
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a experimenty na lidech $7 D006805
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a lidé $7 D006801
- 700 1_
- $a Noury, N.
- 700 1_
- $a Lundy, J.-E.
- 773 0_
- $w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 80-84 $x 0301-5491
- 856 41
- $u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 9
- 990 __
- $a 20091016134404 $b ABA008
- 991 __
- $a 20091020101238 $b ABA008
- 999 __
- $a ok $b bmc $g 690172 $s 552057
- BAS __
- $a 3
- BMC __
- $a 2008 $b 38 $c 2 $d 80-84 $i 0301-5491 $m Lékař a technika $x MED00011033
- LZP __
- $a 2009-54/vtal