Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Results on the evaluation of an embedded fall sensor

J. Poujaud, N. Noury, and J.-E. Lundy

. 2008 ; 38 (2) : 80-84.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc07531318

The fall of elderly people is an important public health problem. Fall has physical, but also psychological consequences. For years, many researches were carried out in this fi eld by Scientists of all around the world. Some prototypes provided reliable results but most of them are not yet wearable devices and, further more, not scalable. An embedded fall sensor was developed by TIMC-IMAG laboratory. It is now at the stage of industrialisation. In this paper we will focus on the evaluation of this fall sensor with 14 healthy volunteers on our experimental “fall” platform. We also will describe our original method to determine the reliability of a fall sensor.

The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic

Bibliografie atd.

Lit.: 14

000      
00000naa 2200000 a 4500
001      
bmc07531318
003      
CZ-PrNML
005      
20111210152029.0
008      
091017s2008 xr e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Poujaud, Julien
245    10
$a Results on the evaluation of an embedded fall sensor / $c J. Poujaud, N. Noury, and J.-E. Lundy
314    __
$a TIMC-IMAG Laboratory, Grenoble, France
500    __
$a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
504    __
$a Lit.: 14
520    9_
$a The fall of elderly people is an important public health problem. Fall has physical, but also psychological consequences. For years, many researches were carried out in this fi eld by Scientists of all around the world. Some prototypes provided reliable results but most of them are not yet wearable devices and, further more, not scalable. An embedded fall sensor was developed by TIMC-IMAG laboratory. It is now at the stage of industrialisation. In this paper we will focus on the evaluation of this fall sensor with 14 healthy volunteers on our experimental “fall” platform. We also will describe our original method to determine the reliability of a fall sensor.
650    _2
$a křehký senior $x psychologie $x statistika a číselné údaje $7 D016330
650    _2
$a pohybové poruchy $x komplikace $x rehabilitace $7 D009069
650    _2
$a ambulantní monitorování $x metody $x přístrojové vybavení $x využití $7 D018670
650    _2
$a biomedicínské inženýrství $x metody $x přístrojové vybavení $7 D001698
650    _2
$a lékařská elektronika $x metody $x přístrojové vybavení $7 D004582
650    _2
$a zdravotnické prostředky $7 D004864
650    _2
$a elektrické vybavení a zdroje $7 D055615
650    _2
$a počítačové zpracování signálu $7 D012815
650    _2
$a algoritmy $7 D000465
650    _2
$a experimenty na lidech $7 D006805
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a senioři $7 D000368
650    _2
$a lidé $7 D006801
700    1_
$a Noury, N.
700    1_
$a Lundy, J.-E.
773    0_
$w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 80-84 $x 0301-5491
856    41
$u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y 9
990    __
$a 20091016134404 $b ABA008
991    __
$a 20091020101238 $b ABA008
999    __
$a ok $b bmc $g 690172 $s 552057
BAS    __
$a 3
BMC    __
$a 2008 $b 38 $c 2 $d 80-84 $i 0301-5491 $m Lékař a technika $x MED00011033
LZP    __
$a 2009-54/vtal

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...