Possibilities of intracranial monitoring of local physiological parameters

Richard Grünes, Karel Roubík

. 2008 ; 38 (2) : 156-159.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc07531380

The article deals with selection of a suitable method for an intracranial measurement of physiological parameters of the brain tissue. The goals of a subsequent clinical study will be investigation of the local physiological parameters of the brain tissue (partial pressure of oxygen – PO2, partial pressure of carbon dioxide – PCO2, acidity – pH, electrical activity, etc.) and their relationship with the selected artifi cial lung ventilation parameters. The methods suitable for measuring these physiological parameters include the measuring by metal microelectrodes, microelectrode arrays (MEAs) or optical methods as fi bber-optic sensors and near infrared spectroscopy (NIRS).

The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic

Bibliografie atd.

Lit.: 6

000      
00000naa 2200000 a 4500
001      
bmc07531380
003      
CZ-PrNML
005      
20111210152040.0
008      
091019s2008 xr e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Grünes, Richard $7 mzk2008448547
245    10
$a Possibilities of intracranial monitoring of local physiological parameters / $c Richard Grünes, Karel Roubík
314    __
$a Czech Technical University in Prague, Faculty of Biomedical Engineering, Department of Biomedical Technology, Kladno
500    __
$a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
504    __
$a Lit.: 6
520    9_
$a The article deals with selection of a suitable method for an intracranial measurement of physiological parameters of the brain tissue. The goals of a subsequent clinical study will be investigation of the local physiological parameters of the brain tissue (partial pressure of oxygen – PO2, partial pressure of carbon dioxide – PCO2, acidity – pH, electrical activity, etc.) and their relationship with the selected artifi cial lung ventilation parameters. The methods suitable for measuring these physiological parameters include the measuring by metal microelectrodes, microelectrode arrays (MEAs) or optical methods as fi bber-optic sensors and near infrared spectroscopy (NIRS).
650    _2
$a mozek $x fyziologie $7 D001921
650    _2
$a umělé dýchání $x metody $x přístrojové vybavení $x využití $7 D012121
650    _2
$a monitorování fyziologických funkcí $x metody $x přístrojové vybavení $x využití $7 D008991
650    _2
$a mozek - chemie $x fyziologie $7 D001923
650    _2
$a experimenty na zvířatech $7 D032761
650    _2
$a potkani Wistar $7 D017208
650    _2
$a mikroelektrody $x využití $7 D008839
650    _2
$a počítačové zpracování signálu $x přístrojové vybavení $7 D012815
650    _2
$a optická vlákna $7 D055100
650    _2
$a blízká infračervená spektroskopie $x metody $x přístrojové vybavení $x využití $7 D019265
650    _2
$a financování organizované $7 D005381
650    _2
$a zvířata $7 D000818
700    1_
$a Roubík, Karel, $d 1971- $7 ntka173892
773    0_
$w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 156-159 $x 0301-5491
856    41
$u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y 9
990    __
$a 20091016134404 $b ABA008
991    __
$a 20091020101929 $b ABA008
999    __
$a ok $b bmc $g 690233 $s 552119
BAS    __
$a 3
BMC    __
$a 2008 $b 38 $c 2 $d 156-159 $i 0301-5491 $m Lékař a technika $x MED00011033
LZP    __
$a 2009-54/vtal

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...