Fast methods of water sampling and scraping from water tank surface were described. The analyses were performed using paddle testers or tests of biological activity. The tests were informative but fully sufficient for manipulation with water tanks. The investigated microbiological parameters include the growth limits for aerobic bacteria at 36 °C and 22 °C (titres 0?102 and 0?103, respectively), limit for disinfection control (tjtres 0?102), limit for micromycetes (titre 0?10) and coliform bacteria (0). Based on the obtained values for microbial contamination, water tanks are categorized and suitable measures are proposed such as optimization of operations and cleaning. Microbial control of air in water tanks was also carried out. Design of a suitable filter unit was also a part of complex monitoring. A filtration unit ECO-Aer with six gradual filtres was mounted in the accumulation area.
Providing healthy and safe drinking water in distribution systems
Lit.: 13
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10003540
- 003
- CZ-PrNML
- 005
- 20111210155753.0
- 008
- 100212s2009 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Říhová Ambrožová, Jana. $7 mzk2003193081
- 245 10
- $a Zajištění zdravotně nezávadné a bezpečné pitné vody v distribuční síti / $c Jana Říhová Ambrožová
- 246 11
- $a Providing healthy and safe drinking water in distribution systems
- 314 __
- $a Ústav technologie vody a prostředí, FTOP, VŠCHT, Praha
- 504 __
- $a Lit.: 13
- 520 9_
- $a Fast methods of water sampling and scraping from water tank surface were described. The analyses were performed using paddle testers or tests of biological activity. The tests were informative but fully sufficient for manipulation with water tanks. The investigated microbiological parameters include the growth limits for aerobic bacteria at 36 °C and 22 °C (titres 0?102 and 0?103, respectively), limit for disinfection control (tjtres 0?102), limit for micromycetes (titre 0?10) and coliform bacteria (0). Based on the obtained values for microbial contamination, water tanks are categorized and suitable measures are proposed such as optimization of operations and cleaning. Microbial control of air in water tanks was also carried out. Design of a suitable filter unit was also a part of complex monitoring. A filtration unit ECO-Aer with six gradual filtres was mounted in the accumulation area.
- 650 _2
- $a zásobování vodou $7 D014881
- 650 _2
- $a mikrobiologie vody $7 D014871
- 650 _2
- $a znečištění vody $x prevence a kontrola $7 D014876
- 650 _2
- $a biofilmy $x růst a vývoj $7 D018441
- 650 _2
- $a financování organizované $7 D005381
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 103, č. 12 (2009), s. 1041-1046 $x 0009-2770
- 856 41
- $u http://www.chemicke-listy.cz/docs/full/2009_12_1041-1046.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 8
- 990 __
- $a 20100211143108 $b ABA008
- 991 __
- $a 20100212101207 $b ABA008
- 999 __
- $a ok $b bmc $g 709468 $s 572282
- BAS __
- $a 3
- BMC __
- $a 2009 $b 103 $c 12 $d 1041-1046 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $a 2010-06/ipmv