Validation of the Sysmex XN analyser and Blood Bank mode for the quality and safety of donor blood and transfusion products

O. Valina, I. Vankova, K. Mintzas, K. Knappova, Z. Gasova

. 2024 ; 34 (1) : 30-38. [pub] 20240109

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24007302

OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24007302
003      
CZ-PrNML
005      
20240423155849.0
007      
ta
008      
240412s2024 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/tme.13028 $2 doi
035    __
$a (PubMed)38193379
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Valina, Ondrej $u Haematology Department, Sysmex Europe SE, Norderstedt, Germany
245    10
$a Validation of the Sysmex XN analyser and Blood Bank mode for the quality and safety of donor blood and transfusion products / $c O. Valina, I. Vankova, K. Mintzas, K. Knappova, Z. Gasova
520    9_
$a OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.
650    _2
$a lidé $7 D006801
650    12
$a dárci krve $7 D001782
650    12
$a krevní banky $7 D001771
650    _2
$a krevní obraz $x metody $7 D001772
650    _2
$a počet trombocytů $7 D010976
650    _2
$a erytrocyty $7 D004912
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vankova, Ida $u Apheresis and Transfusion Departments, Institute of Haematology and Blood Transfusion, Prague, Czech Republic
700    1_
$a Mintzas, Konstantinos $u Haematology Department, Sysmex Europe SE, Norderstedt, Germany
700    1_
$a Knappova, Klara $u Apheresis and Transfusion Departments, Institute of Haematology and Blood Transfusion, Prague, Czech Republic
700    1_
$a Gasova, Zdenka $u Apheresis and Transfusion Departments, Institute of Haematology and Blood Transfusion, Prague, Czech Republic
773    0_
$w MED00004548 $t Transfusion medicine $x 1365-3148 $g Roč. 34, č. 1 (2024), s. 30-38
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38193379 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240412 $b ABA008
991    __
$a 20240423155845 $b ABA008
999    __
$a ok $b bmc $g 2081343 $s 1217069
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 34 $c 1 $d 30-38 $e 20240109 $i 1365-3148 $m Transfusion medicine $n Transfus Med $x MED00004548
LZP    __
$a Pubmed-20240412

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...