• Je něco špatně v tomto záznamu ?

Umístění zevního automatického defibrilátoru a jeho užitečnost
[Location of cardiac arrest in a city center: strategic placement of automated external defibrillators in public locations]

F. Folke, et al.

. 2009 ; 3 (6) : 52-53.

Jazyk čeština Země Česko

Typ dokumentu veřejná zařízení

Perzistentní odkaz   https://www.medvik.cz/link/bmc10004581

Public-access defibrillation with automated external defibrillators (AEDs) is being implemented in many countries worldwide with considerable financial implications. The potential benefit and economic consequences of focused or unfocused AED deployment are unknown. METHODS AND RESULTS: All cardiac arrests in public in Copenhagen, Denmark, from 1994 through 2005 were geographically located, as were 104 public AEDs placed by local initiatives. In accordance with European Resuscitation Council and American Heart Association (AHA) guidelines, areas with a high incidence of cardiac arrests were defined as those with 1 cardiac arrest every 2 or 5 years, respectively. There were 1274 cardiac arrests in public locations. According to the European Resuscitation Council or AHA guidelines, AEDs needed to be deployed in 1.2% and 10.6% of the city area, providing coverage for 19.5% (n=249) and 66.8% (n=851) of all cardiac arrests, respectively. The excessive cost of such AED deployments was estimated to be $33 100 or $41 000 per additional quality-adjusted life year, whereas unguided AED placement covering the entire city had an estimated cost of $108 700 per quality-adjusted life year. Areas with major train stations (1.8 arrests every 5 years per area), large public squares, and pedestrianized areas (0.6 arrests every 5 years per area) were main predictors of frequent cardiac arrests. CONCLUSIONS: To achieve wide AED coverage, AEDs need to be more widely distributed than recommended by the European Resuscitation Council guidelines but consistent with the American Heart Association guidelines. Strategic placement of AEDs is pivotal for public-access defibrillation, whereas with unguided initiatives, AEDs are likely to be placed inappropriately.

Location of cardiac arrest in a city center: strategic placement of automated external defibrillators in public locations

000      
00000naa 2200000 a 4500
001      
bmc10004581
003      
CZ-PrNML
005      
20111210160505.0
008      
100223s2009 xr e cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Folke, Fredrik
245    10
$a Umístění zevního automatického defibrilátoru a jeho užitečnost / $c F. Folke, et al.
246    11
$a Location of cardiac arrest in a city center: strategic placement of automated external defibrillators in public locations
314    __
$a Research Fellow, Department of Cardiology, Gentofte University Hospital, Hellerup FF@heart.dk
520    9_
$a Public-access defibrillation with automated external defibrillators (AEDs) is being implemented in many countries worldwide with considerable financial implications. The potential benefit and economic consequences of focused or unfocused AED deployment are unknown. METHODS AND RESULTS: All cardiac arrests in public in Copenhagen, Denmark, from 1994 through 2005 were geographically located, as were 104 public AEDs placed by local initiatives. In accordance with European Resuscitation Council and American Heart Association (AHA) guidelines, areas with a high incidence of cardiac arrests were defined as those with 1 cardiac arrest every 2 or 5 years, respectively. There were 1274 cardiac arrests in public locations. According to the European Resuscitation Council or AHA guidelines, AEDs needed to be deployed in 1.2% and 10.6% of the city area, providing coverage for 19.5% (n=249) and 66.8% (n=851) of all cardiac arrests, respectively. The excessive cost of such AED deployments was estimated to be $33 100 or $41 000 per additional quality-adjusted life year, whereas unguided AED placement covering the entire city had an estimated cost of $108 700 per quality-adjusted life year. Areas with major train stations (1.8 arrests every 5 years per area), large public squares, and pedestrianized areas (0.6 arrests every 5 years per area) were main predictors of frequent cardiac arrests. CONCLUSIONS: To achieve wide AED coverage, AEDs need to be more widely distributed than recommended by the European Resuscitation Council guidelines but consistent with the American Heart Association guidelines. Strategic placement of AEDs is pivotal for public-access defibrillation, whereas with unguided initiatives, AEDs are likely to be placed inappropriately.
650    _2
$a financování organizované $7 D005381
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a kardiopulmonální resuscitace $x ekonomika $x mortalita $x statistika a číselné údaje $7 D016887
650    _2
$a analýza nákladů a výnosů $7 D003362
650    _2
$a defibrilátory $x ekonomika $x statistika a číselné údaje $7 D047548
650    _2
$a elektrická defibrilace $x ekonomika $x mortalita $x přístrojové vybavení $7 D004554
650    _2
$a urgentní zdravotnické služby $x ekonomika $x statistika a číselné údaje $7 D004632
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a zdravotnické plánování - směrnice $7 D006287
650    _2
$a dostupnost zdravotnických služeb $7 D006297
650    _2
$a srdeční zástava $x ekonomika $x mortalita $x terapie $7 D006323
650    _2
$a lidé $7 D006801
650    _2
$a incidence $7 D015994
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a městské obyvatelstvo $7 D014505
651    _2
$a Dánsko $x epidemiologie $7 D003718
655    _2
$a veřejná zařízení $7 D011633
773    0_
$w MED00012706 $t Clinical cardiology alert $g Roč. 3, č. 6 (2009), s. 52-53 $x 1213-2586
787    18
$w bmc10004582 $i Recenze v: $t Komentář [k článku Umístění zevního automatického defibrilátoru a jeho užitečnost]
910    __
$a ABA008 $b B 2242 $c 407 a $y 8
990    __
$a 20100222144357 $b ABA008
991    __
$a 20100503101341 $b ABA008
999    __
$a ok $b bmc $g 714003 $s 576951
BAS    __
$a 3
BMC    __
$a 2009 $b 3 $c 6 $d 52-53 $i 1213-2586 $m Clinical Cardiology Alert $x MED00012706
LZP    __
$a 2010-03/mkme

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...