Je něco špatně v tomto záznamu ?
Poor survival of ABG I hip prosthesis in younger patients
Jiri Gallo, Katerina Langova, Vitezslav Havranek, Ivana Cechova
Jazyk angličtina Země Česko
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
- MeSH
- analýza přežití MeSH
- dospělí MeSH
- financování organizované MeSH
- hydroxyapatit terapeutické užití MeSH
- Kaplanův-Meierův odhad MeSH
- lidé MeSH
- náhrada kyčelního kloubu metody využití MeSH
- osteolýza MeSH
- polyethylen terapeutické užití MeSH
- retrospektivní studie MeSH
- statistika jako téma MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
Background: Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than twodecades. However, the majority of studies have reported only intermediate term outcomes that are not reliable forpredicting long-term behavior in all implants. The aim of this study was to determine the performance of HAC totalhip arthroplasty in younger patients over a 10-year follow-up period.Methods and Results: This was an observational retrospective study of a 137 consecutive hips with the ABG I prosthesis.Of these, 128 were available for the last investigation. Median duration of follow-up was 10.9 years. The meanage at time of index surgery was 46±6.7 years. Probability of implant survival was estimated using the Kaplan-Meiermethod. The overall 12-year cumulative survival was 0.55 (95% CI, 0.443-0.659). Periprosthetic osteolysis (57 %) wasthe most frequent reason for failure followed by aseptic loosening (28 %). When only aseptic loosening was includedin the analysis, the same fi gures for cup and stem were 0.873 (95% CI, 0.808-0.938) and 0.992 (95% CI, 0.976- 1.0),respectively. Patients with a smaller cup size were those at high risk for revision due to wear-related complications(odds ratio, OR=4.3; 95% CI, 1.734-10.555).Conclusion: This study reports one of the poorest 12-year survivorship data for cementless acetabular componentin the literature. The main reason for premature failure was osteolysis, strongly related to high wear rate of polyethylene.
Citace poskytuje Crossref.org
Lit.: 25
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10009385
- 003
- CZ-PrNML
- 005
- 20111210162324.0
- 008
- 100420s2008 xr e eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2008.027 $2 doi
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Gallo, Jiří $7 xx0019005
- 245 10
- $a Poor survival of ABG I hip prosthesis in younger patients / $c Jiri Gallo, Katerina Langova, Vitezslav Havranek, Ivana Cechova
- 314 __
- $a Department of Orthopedics, Teaching Hospital and Faculty of Medicine and Dentistry, Palacky University, Olomouc
- 504 __
- $a Lit.: 25
- 520 9_
- $a Background: Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than twodecades. However, the majority of studies have reported only intermediate term outcomes that are not reliable forpredicting long-term behavior in all implants. The aim of this study was to determine the performance of HAC totalhip arthroplasty in younger patients over a 10-year follow-up period.Methods and Results: This was an observational retrospective study of a 137 consecutive hips with the ABG I prosthesis.Of these, 128 were available for the last investigation. Median duration of follow-up was 10.9 years. The meanage at time of index surgery was 46±6.7 years. Probability of implant survival was estimated using the Kaplan-Meiermethod. The overall 12-year cumulative survival was 0.55 (95% CI, 0.443-0.659). Periprosthetic osteolysis (57 %) wasthe most frequent reason for failure followed by aseptic loosening (28 %). When only aseptic loosening was includedin the analysis, the same fi gures for cup and stem were 0.873 (95% CI, 0.808-0.938) and 0.992 (95% CI, 0.976- 1.0),respectively. Patients with a smaller cup size were those at high risk for revision due to wear-related complications(odds ratio, OR=4.3; 95% CI, 1.734-10.555).Conclusion: This study reports one of the poorest 12-year survivorship data for cementless acetabular componentin the literature. The main reason for premature failure was osteolysis, strongly related to high wear rate of polyethylene.
- 650 _2
- $a náhrada kyčelního kloubu $x metody $x využití $7 D019644
- 650 _2
- $a hydroxyapatit $x terapeutické užití $7 D017886
- 650 _2
- $a osteolýza $7 D010014
- 650 _2
- $a polyethylen $x terapeutické užití $7 D020959
- 650 _2
- $a statistika jako téma $7 D013223
- 650 _2
- $a analýza přežití $7 D016019
- 650 _2
- $a Kaplanův-Meierův odhad $7 D053208
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Langová, Kateřina $7 xx0141371
- 700 1_
- $a Havránek, Vítězslav. $7 _AN047673
- 700 1_
- $a Čechová, Ivana $7 xx0093685
- 773 0_
- $w MED00012606 $t Biomedical papers $g Roč. 152, č. 1 (2008), s. 163-168 $x 1213-8118
- 856 41
- $u http://biomed.papers.upol.cz/pdfs/bio/2008/01/27.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 1502 $c 958 $y 8
- 990 __
- $a 20100419115931 $b ABA008
- 991 __
- $a 20100510153214 $b ABA008
- 999 __
- $a ok $b bmc $g 723260 $s 586375
- BAS __
- $a 3
- BMC __
- $a 2008 $b 152 $c 1 $d 163-168 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $x MED00012606
- LZP __
- $a 2010-22/dkal