Je něco špatně v tomto záznamu ?
Voltammetric and amperometric determination of doxorubicin using carbon paste electrodes
Zuzana Jemelková, Jiří Zima and Jiří Barek
Jazyk angličtina Země Česko
NLK
ProQuest Central
od 2005-01-01 do 2011
- MeSH
- doxorubicin analýza MeSH
- elektrochemie metody MeSH
- elektrody MeSH
- financování organizované MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
Direct current voltammetric (DCV) and differential pulse voltammetric (DPV) determination of antineoplastic agent doxorubicin (DOX) at a carbon paste electrode (CPE) was developed. Britton–Robinson buffer (pH 7.0) was used as a supporting electrolyte. The limits of detection are 8 × 10–7 mol l–1 (DCV) and 6 × 10–8 mol l–1 (DPV). The accumulation of DOX at the electrode surface was used to decrease the limits of detection down to 2.2 × 10–7 mol l–1 for adsorptive stripping DC voltammetry (DCAdSV) and 2.8 × 10–9 mol l–1 for adsorptive stripping differential pulse voltammetry (DPAdSV) at CPE. The results of the voltammetric methods were utilized for the development of a new determination of doxorubicin using HPLC with amperometric detection on CPE based on spherical microparticles of glassy carbon in a wall-jet configuration. A column with chemically bonded C18 stationary phase and a mobile phase containing 0.01 M phosphate buffer (pH 5.0)–methanol 25:75 (v/v) were used. The limit of detection is 4 × 10–7 mol l–1 (HPLC with electrochemical detection (ED)).
Lit.: 35
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10012162
- 003
- CZ-PrNML
- 005
- 20111210163119.0
- 008
- 100520s2009 xr e eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.1135/cccc2009081
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Jemelková, Zuzana $7 xx0120143
- 245 10
- $a Voltammetric and amperometric determination of doxorubicin using carbon paste electrodes / $c Zuzana Jemelková, Jiří Zima and Jiří Barek
- 314 __
- $a UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 2030, 128 43 Prague 2, Czech Republic
- 504 __
- $a Lit.: 35
- 520 3_
- $a Direct current voltammetric (DCV) and differential pulse voltammetric (DPV) determination of antineoplastic agent doxorubicin (DOX) at a carbon paste electrode (CPE) was developed. Britton–Robinson buffer (pH 7.0) was used as a supporting electrolyte. The limits of detection are 8 × 10–7 mol l–1 (DCV) and 6 × 10–8 mol l–1 (DPV). The accumulation of DOX at the electrode surface was used to decrease the limits of detection down to 2.2 × 10–7 mol l–1 for adsorptive stripping DC voltammetry (DCAdSV) and 2.8 × 10–9 mol l–1 for adsorptive stripping differential pulse voltammetry (DPAdSV) at CPE. The results of the voltammetric methods were utilized for the development of a new determination of doxorubicin using HPLC with amperometric detection on CPE based on spherical microparticles of glassy carbon in a wall-jet configuration. A column with chemically bonded C18 stationary phase and a mobile phase containing 0.01 M phosphate buffer (pH 5.0)–methanol 25:75 (v/v) were used. The limit of detection is 4 × 10–7 mol l–1 (HPLC with electrochemical detection (ED)).
- 650 _2
- $a doxorubicin $x analýza $7 D004317
- 650 _2
- $a elektrochemie $x metody $7 D004563
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Zima, Jiří, $d 1956- $7 jn20000402749
- 700 1_
- $a Barek, Jiří, $d 1949- $7 jn20000400068
- 773 0_
- $w MED00010973 $t Collection of Czechoslovak chemical communications $g Roč. 74, č. 10 (2009), s. 1503-1515 $x 0010-0765
- 910 __
- $a ABA008 $b A 1006 $c 394 $y 8
- 990 __
- $a 20100520081609 $b ABA008
- 991 __
- $a 20100520095033 $b ABA008
- 999 __
- $a ok $b bmc $g 726019 $s 589172
- BAS __
- $a 3
- BMC __
- $a 2009 $b 74 $c 10 $m Collection of Czechoslovak Chemical Communications $x MED00010973 $d 1503-1515
- LZP __
- $a 2010-26/vtmv