Voltammetric and amperometric determination of doxorubicin using carbon paste electrodes

Zuzana Jemelková, Jiří Zima and Jiří Barek

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc10012162
E-zdroje

NLK ProQuest Central od 2005-01-01 do 2011

Direct current voltammetric (DCV) and differential pulse voltammetric (DPV) determination of antineoplastic agent doxorubicin (DOX) at a carbon paste electrode (CPE) was developed. Britton–Robinson buffer (pH 7.0) was used as a supporting electrolyte. The limits of detection are 8 × 10–7 mol l–1 (DCV) and 6 × 10–8 mol l–1 (DPV). The accumulation of DOX at the electrode surface was used to decrease the limits of detection down to 2.2 × 10–7 mol l–1 for adsorptive stripping DC voltammetry (DCAdSV) and 2.8 × 10–9 mol l–1 for adsorptive stripping differential pulse voltammetry (DPAdSV) at CPE. The results of the voltammetric methods were utilized for the development of a new determination of doxorubicin using HPLC with amperometric detection on CPE based on spherical microparticles of glassy carbon in a wall-jet configuration. A column with chemically bonded C18 stationary phase and a mobile phase containing 0.01 M phosphate buffer (pH 5.0)–methanol 25:75 (v/v) were used. The limit of detection is 4 × 10–7 mol l–1 (HPLC with electrochemical detection (ED)).

Bibliografie atd.

Lit.: 35

000      
00000naa 2200000 a 4500
001      
bmc10012162
003      
CZ-PrNML
005      
20111210163119.0
008      
100520s2009 xr e eng||
009      
AR
024    7_
$2 doi $a 10.1135/cccc2009081
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Jemelková, Zuzana $7 xx0120143
245    10
$a Voltammetric and amperometric determination of doxorubicin using carbon paste electrodes / $c Zuzana Jemelková, Jiří Zima and Jiří Barek
314    __
$a UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 2030, 128 43 Prague 2, Czech Republic
504    __
$a Lit.: 35
520    3_
$a Direct current voltammetric (DCV) and differential pulse voltammetric (DPV) determination of antineoplastic agent doxorubicin (DOX) at a carbon paste electrode (CPE) was developed. Britton–Robinson buffer (pH 7.0) was used as a supporting electrolyte. The limits of detection are 8 × 10–7 mol l–1 (DCV) and 6 × 10–8 mol l–1 (DPV). The accumulation of DOX at the electrode surface was used to decrease the limits of detection down to 2.2 × 10–7 mol l–1 for adsorptive stripping DC voltammetry (DCAdSV) and 2.8 × 10–9 mol l–1 for adsorptive stripping differential pulse voltammetry (DPAdSV) at CPE. The results of the voltammetric methods were utilized for the development of a new determination of doxorubicin using HPLC with amperometric detection on CPE based on spherical microparticles of glassy carbon in a wall-jet configuration. A column with chemically bonded C18 stationary phase and a mobile phase containing 0.01 M phosphate buffer (pH 5.0)–methanol 25:75 (v/v) were used. The limit of detection is 4 × 10–7 mol l–1 (HPLC with electrochemical detection (ED)).
650    _2
$a doxorubicin $x analýza $7 D004317
650    _2
$a elektrochemie $x metody $7 D004563
650    _2
$a elektrody $7 D004566
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a financování organizované $7 D005381
700    1_
$a Zima, Jiří, $d 1956- $7 jn20000402749
700    1_
$a Barek, Jiří, $d 1949- $7 jn20000400068
773    0_
$w MED00010973 $t Collection of Czechoslovak chemical communications $g Roč. 74, č. 10 (2009), s. 1503-1515 $x 0010-0765
910    __
$a ABA008 $b A 1006 $c 394 $y 8
990    __
$a 20100520081609 $b ABA008
991    __
$a 20100520095033 $b ABA008
999    __
$a ok $b bmc $g 726019 $s 589172
BAS    __
$a 3
BMC    __
$a 2009 $b 74 $c 10 $m Collection of Czechoslovak Chemical Communications $x MED00010973 $d 1503-1515
LZP    __
$a 2010-26/vtmv

Najít záznam