-
Je něco špatně v tomto záznamu ?
Voltametrické stanovení 1-nitropyrenu a 1-aminopyrenu na borem dopované diamantové filmové elektrodě
[Voltammetric determination of 1-nitropyrene and 1-aminopyrene at a boron-doped diamond film electrode]
Oksana Yosypchuk, Karolína Pecková, Jiří Barek
Jazyk čeština Země Česko
- MeSH
- elektrochemie metody MeSH
- elektrody MeSH
- financování organizované MeSH
- látky znečišťující vzduch analýza MeSH
- pyreny analýza MeSH
Optimum conditions for the determination of carcinogenic 1-nitropyrene (NP) and 1-aminopyrene (AP) by differential pulse voltammetry with a boron-doped diamond film electrode were found ? aqueous-methanolic (3:7) Britton-Robinson buffer (pH 3), scan rate 20 mV s–1, pulse duration 100 ms, pulse amplitude ?50 mV (NP) and 50 mV (AP). The regeneration in NP determination was carried out before analysis by switching fifty-times between the potentials 800 mV and –500 mV every 0.3 s. In determination of AP, no regeneration was needed. The limits of quantification were 8·10–7 and 2·10–7 mol dm?3 for NP and AP, respectively.
Voltammetric determination of 1-nitropyrene and 1-aminopyrene at a boron-doped diamond film electrode
Lit.: 17
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10012216
- 003
- CZ-PrNML
- 005
- 20111210163129.0
- 008
- 100520s2010 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Yosypchuk, Oksana $7 xx0119382
- 245 10
- $a Voltametrické stanovení 1-nitropyrenu a 1-aminopyrenu na borem dopované diamantové filmové elektrodě / $c Oksana Yosypchuk, Karolína Pecková, Jiří Barek
- 246 11
- $a Voltammetric determination of 1-nitropyrene and 1-aminopyrene at a boron-doped diamond film electrode
- 314 __
- $a Univerzita Karlova v Praze, Přírodovědecká fakulta, Katedra analytické chemie, UNESCO Laboratoř elektrochemie životního prostředí, Praha 2
- 504 __
- $a Lit.: 17
- 520 9_
- $a Optimum conditions for the determination of carcinogenic 1-nitropyrene (NP) and 1-aminopyrene (AP) by differential pulse voltammetry with a boron-doped diamond film electrode were found ? aqueous-methanolic (3:7) Britton-Robinson buffer (pH 3), scan rate 20 mV s–1, pulse duration 100 ms, pulse amplitude ?50 mV (NP) and 50 mV (AP). The regeneration in NP determination was carried out before analysis by switching fifty-times between the potentials 800 mV and –500 mV every 0.3 s. In determination of AP, no regeneration was needed. The limits of quantification were 8·10–7 and 2·10–7 mol dm?3 for NP and AP, respectively.
- 650 _2
- $a látky znečišťující vzduch $x analýza $7 D000393
- 650 _2
- $a pyreny $x analýza $7 D011721
- 650 _2
- $a elektrochemie $x metody $7 D004563
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Schwarzová, Karolina, $d 1976 prosinec 26.- $7 uk2007300495
- 700 1_
- $a Barek, Jiří, $d 1949- $7 jn20000400068
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 104, č. 3 (2010), s. 186-190 $x 0009-2770
- 856 41
- $u http://www.chemicke-listy.cz/docs/full/2010_03_186-190.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 8
- 990 __
- $a 20100520130225 $b ABA008
- 991 __
- $a 20100606162339 $b ABA008
- 999 __
- $a ok $b bmc $g 726073 $s 589226
- BAS __
- $a 3
- BMC __
- $a 2010 $b 104 $c 3 $m Chemické listy $x MED00011010 $d 186-190
- LZP __
- $a 2010-26/vtmv