Something wrong with this record ?
A high-power laser-driven source of sub-nanosecond soft X-ray pulses for single-shot radiobiology experiments
M Davidkova, L Juha, M Bittner, S Koptyaev, V Hajkova, J Krasa, M Pfeifer, V Stisova, A Bartnik, H Fiedorowicz, J Mikolajczyk, L Ryc, L Pina, M Horvath, D Babankova, J Cihelka, S Civis
Language English Country United States
Document type Evaluation Study
- MeSH
- Equipment Failure Analysis MeSH
- Radiation Dosage MeSH
- Equipment Design MeSH
- Lasers MeSH
- Nanotechnology methods instrumentation MeSH
- Specimen Handling methods instrumentation MeSH
- Plasmids chemistry drug effects MeSH
- DNA Damage radiation effects MeSH
- Radiobiology methods instrumentation MeSH
- X-Rays MeSH
- Research instrumentation MeSH
- Research Design MeSH
- Publication type
- Evaluation Study MeSH
A large-scale, double-stream gas puff target has been illuminated by sub-kJ, near-infrared (NIR) focused laser pulses at the PALS facility (Prague Asterix Laser System) to produce high-energy pulses of soft X rays from hot, dense plasma. The double-puff arrangement ensures high gas density and conversion efficiency from NIR to X rays approaching that typical for solid targets. In addition, its major advantage over solid targets is that it is free of debris and has substantially suppressed charged-particle emission. The X-ray emission characteristics of the source were determined for a range of gases that included krypton, xenon, N(2), CO and N(2)-CO. A demonstrated application of the xenon-based source is a single-shot damage induction to plasmid DNA. The yields of single-strand breaks (SSBs) and double-strand breaks (DSBs) were determined as a function of energy fluence adjusted by varying distance of sample from the source and thickness of aluminum filters.
- 000
- 03175naa 2200589 a 4500
- 001
- bmc10013244
- 003
- CZ-PrNML
- 005
- 20121114095624.0
- 008
- 100602s2007 xxu e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Davídková, Marie. $7 stk2007383287
- 245 12
- $a A high-power laser-driven source of sub-nanosecond soft X-ray pulses for single-shot radiobiology experiments / $c M Davidkova, L Juha, M Bittner, S Koptyaev, V Hajkova, J Krasa, M Pfeifer, V Stisova, A Bartnik, H Fiedorowicz, J Mikolajczyk, L Ryc, L Pina, M Horvath, D Babankova, J Cihelka, S Civis
- 314 __
- $a Department of Radiation Dosimetry, Institute of Nuclear Physics, Academy of Sciences of the Czech Republic, 180 86, Prague 8, Czech Republic. davidkova@ujf.cas.cz
- 520 9_
- $a A large-scale, double-stream gas puff target has been illuminated by sub-kJ, near-infrared (NIR) focused laser pulses at the PALS facility (Prague Asterix Laser System) to produce high-energy pulses of soft X rays from hot, dense plasma. The double-puff arrangement ensures high gas density and conversion efficiency from NIR to X rays approaching that typical for solid targets. In addition, its major advantage over solid targets is that it is free of debris and has substantially suppressed charged-particle emission. The X-ray emission characteristics of the source were determined for a range of gases that included krypton, xenon, N(2), CO and N(2)-CO. A demonstrated application of the xenon-based source is a single-shot damage induction to plasmid DNA. The yields of single-strand breaks (SSBs) and double-strand breaks (DSBs) were determined as a function of energy fluence adjusted by varying distance of sample from the source and thickness of aluminum filters.
- 650 _2
- $a poškození DNA $x účinky záření $7 D004249
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a analýza selhání vybavení $7 D019544
- 650 _2
- $a lasery $7 D007834
- 650 _2
- $a nanotechnologie $x metody $x přístrojové vybavení $7 D036103
- 650 _2
- $a plazmidy $x chemie $x účinky léků $7 D010957
- 650 _2
- $a dávka záření $7 D011829
- 650 _2
- $a radiobiologie $x metody $x přístrojové vybavení $7 D011853
- 650 _2
- $a výzkum $x přístrojové vybavení $7 D012106
- 650 _2
- $a odběr biologického vzorku $x metody $x přístrojové vybavení $7 D013048
- 650 _2
- $a rentgenové záření $7 D014965
- 650 _2
- $a výzkumný projekt $7 D012107
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Juha, Libor $7 xx0076280
- 700 1_
- $a Bittner, Michal. $7 jx20100408014
- 700 1_
- $a Koptyaev, Sergey
- 700 1_
- $a Hájková, Věra $7 jx20040813008
- 700 1_
- $a Krása, Josef. $7 _AN055211
- 700 1_
- $a Pfeifer, Miroslav $7 xx0169489
- 700 1_
- $a Štísová, Viktorie. $7 stk2007383290
- 700 1_
- $a Bartnik, Andrzej
- 700 1_
- $a Fiedorowicz, Henryk
- 700 1_
- $a Mikolajczyk, Janusz
- 700 1_
- $a Ryc, Leszek
- 700 1_
- $a Pína, Ladislav. $7 _AN058085
- 700 1_
- $a Horváth, Martin
- 700 1_
- $a Babánková, Dagmar, $d 1978- $7 xx0133700
- 700 1_
- $a Cihelka, Jaroslav. $7 _BN007289
- 700 1_
- $a Civiš, Svatopluk. $7 _BN007290
- 773 0_
- $t Radiation Research $w MED00010511 $g Roč. 168, č. 3 (2007), s. 382-387 $x 0033-7587
- 910 __
- $a ABA008 $b x $y 7
- 990 __
- $a 20110413111114 $b ABA008
- 991 __
- $a 20121114095639 $b ABA008
- 999 __
- $a ok $b bmc $g 749116 $s 612739
- BAS __
- $a 3
- BMC __
- $a 2007 $b 168 $c 3 $d 382-387 $i 0033-7587 $m Radiation research $n Radiat Res $x MED00010511
- LZP __
- $a 2010-B2/ipme