Agarová pracovná elektróda ako podklad pre dvojvrstvovú lipidovú membránu: účinky jednosmerného napätia
[Agar working electrode as a support for bilayer lipid membrane: effects of direct current bias voltages]

Galina Laputková, Michal Legiš, Ján Sabo

. 2010 ; 104 (5) : 353-359.

Language Slovak Country Czech Republic

The agar working electrode as a hydrogel support for bilayer lipid membranes (BLM) was studied by electrochemical impedance spectroscopy. The aim was to study the influence of dc bias voltage on the formation of a stable supported bilayer lipid membrane (s-BLM) on the electrode tip. It was concluded that the hydrogel support is sufficiently stable in the applied range of bias voltages. The agar electrode provides satisfactory results in the frequency range 1–1?104 Hz. The electrode properties suggest applicability in deposition of s-BLM. Electric properties of s-BLM significantly depend on the dc bias voltage. The specific membrane capacitance of s-BLM at ?0.4 V was comparable with that of a conventional planar BLM. However, a shift to negative bias voltages led to a significant change of membrane resistance, possibly due to the increasing number of pores or defective structures in the lipid bilayer.

Agar working electrode as a support for bilayer lipid membrane: effects of direct current bias voltages

Bibliography, etc.

Lit.: 29

000      
00000naa 2200000 a 4500
001      
bmc10013455
003      
CZ-PrNML
005      
20111210175318.0
008      
100607s2010 xr e slo||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a slo $b eng
044    __
$a xr
100    1_
$a Laputková, Galina $7 xx0064189
245    10
$a Agarová pracovná elektróda ako podklad pre dvojvrstvovú lipidovú membránu: účinky jednosmerného napätia / $c Galina Laputková, Michal Legiš, Ján Sabo
246    11
$a Agar working electrode as a support for bilayer lipid membrane: effects of direct current bias voltages
314    __
$a Ústav lekárskej biofyziky, Univerzita Pavla Jozefa Šafárika, Lekárska fakulta, Košice
504    __
$a Lit.: 29
520    9_
$a The agar working electrode as a hydrogel support for bilayer lipid membranes (BLM) was studied by electrochemical impedance spectroscopy. The aim was to study the influence of dc bias voltage on the formation of a stable supported bilayer lipid membrane (s-BLM) on the electrode tip. It was concluded that the hydrogel support is sufficiently stable in the applied range of bias voltages. The agar electrode provides satisfactory results in the frequency range 1–1?104 Hz. The electrode properties suggest applicability in deposition of s-BLM. Electric properties of s-BLM significantly depend on the dc bias voltage. The specific membrane capacitance of s-BLM at ?0.4 V was comparable with that of a conventional planar BLM. However, a shift to negative bias voltages led to a significant change of membrane resistance, possibly due to the increasing number of pores or defective structures in the lipid bilayer.
650    _2
$a lipidové dvojvrstvy $7 D008051
650    _2
$a biosenzitivní techniky $x přístrojové vybavení $7 D015374
650    _2
$a elektrochemie $x metody $x přístrojové vybavení $7 D004563
650    _2
$a financování organizované $7 D005381
700    1_
$a Legiň, Michal. $7 _AN049633
700    1_
$a Sabo, Ján $7 xx0129263
773    0_
$w MED00011010 $t Chemické listy $g Roč. 104, č. 5 (2010), s. 353-359 $x 0009-2770
856    41
$u http://www.chemicke-listy.cz/docs/full/2010_05_353-359.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 8
990    __
$a 20100604105218 $b ABA008
991    __
$a 20100622155909 $b ABA008
999    __
$a ok $b bmc $g 749318 $s 612961
BAS    __
$a 3
BMC    __
$a 2010 $b 104 $c 5 $m Chemické listy $x MED00011010 $d 353-359
LZP    __
$a 2010-29/ipmv

Find record