Label-free piezoelectric immunosensor for rapid assay of Escherichia coli

M Pohanka, P Skladal, O Pavlis

. 2008 ; 29 (1) : 70-79.

Language English Country United States

Document type Evaluation Study

E-resources Online

NLK Medline Complete (EBSCOhost) from 2001-02-01 to 1 year ago

A piezoelectric sensor with immobilized polyclonal antibody was developed as a label-free assay for the model bacterium, Escherichia coli. The polyclonal antibody was prepared from mice BALB/c and covalently immobilized on the sensing gold electrode of the piezoelectric quartz crystal. The biosensor was able to detect E. coli in the range of 10(6)-10(9) CFU/mL; signal of the negative control was not statistically relevant in the selected range. Samples could be analyzed in four minutes and one measuring cycle including regeneration was completed within ten minutes. Repeatability of the developed method is discussed; the signal obtained from three different biosensors was 12.9+/-0.4 Hz for the sample containing 10(8) CFU/mL.

000      
00000naa 2200000 a 4500
001      
bmc10026276
003      
CZ-PrNML
005      
20111210192309.0
008      
101018s2008 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Pohanka, Miroslav $7 hka2010563580
245    10
$a Label-free piezoelectric immunosensor for rapid assay of Escherichia coli / $c M Pohanka, P Skladal, O Pavlis
314    __
$a Center of Biological Defense, Techonin, Czech Republic. rau@atlas.cz
520    9_
$a A piezoelectric sensor with immobilized polyclonal antibody was developed as a label-free assay for the model bacterium, Escherichia coli. The polyclonal antibody was prepared from mice BALB/c and covalently immobilized on the sensing gold electrode of the piezoelectric quartz crystal. The biosensor was able to detect E. coli in the range of 10(6)-10(9) CFU/mL; signal of the negative control was not statistically relevant in the selected range. Samples could be analyzed in four minutes and one measuring cycle including regeneration was completed within ten minutes. Repeatability of the developed method is discussed; the signal obtained from three different biosensors was 12.9+/-0.4 Hz for the sample containing 10(8) CFU/mL.
650    _2
$a zvířata $7 D000818
650    _2
$a protilátky bakteriální $x chemie $x imunologie $7 D000907
650    _2
$a protilátky bakteriální $x imunologie $7 D000907
650    _2
$a biosenzitivní techniky $x metody $7 D015374
650    _2
$a elektrody $7 D004566
650    _2
$a Escherichia coli $x imunologie $x izolace a purifikace $7 D004926
650    _2
$a zlato $x chemie $7 D006046
650    _2
$a myši $7 D051379
650    _2
$a myši inbrední BALB C $7 D008807
650    _2
$a křemen $x chemie $7 D011791
655    _2
$a hodnotící studie $7 D023362
700    1_
$a Skládal, Petr, $d 1964- $7 mub2010598931
700    1_
$a Pavliš, Oto $7 xx0135660
773    0_
$w MED00007286 $t Journal of immunoassay & immunochemistry $g Roč. 29, č. 1 (2008), s. 70-79 $x 1532-1819
910    __
$a ABA008 $b x $y 7
990    __
$a 20101116100155 $b ABA008
991    __
$a 20101205161721 $b ABA008
999    __
$a ok $b bmc $g 801381 $s 666126
BAS    __
$a 3
BMC    __
$a 2008 $b 29 $c 1 $d 70-79 $i 1532-1819 $m Journal of immunoassay & immunochemistry $n J Immunoassay Immunochem $x MED00007286
LZP    __
$a 2010-B/jtme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...