Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals

K Mervartova, M Polasek, Calatayud J Martinez

. 2007 ; 45 (3) : 367-381.

Jazyk angličtina Země Velká Británie

Typ dokumentu přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc10026307

A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies--flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.

Citace poskytuje Crossref.org

000      
00000naa 2200000 a 4500
001      
bmc10026307
003      
CZ-PrNML
005      
20120207152340.0
008      
101018s2007 xxk e eng||
009      
AR
024    __
$a 10.1016/j.jpba.2007.08.018 $2 doi
035    __
$a (PubMed)17900844
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Mervartová, Kateřina. $7 _AN048874
245    10
$a Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals / $c K Mervartova, M Polasek, Calatayud J Martinez
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic. Katerina.Mervartova@faf.cuni.cz
520    9_
$a A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies--flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.
650    _2
$a luminiscenční měření $x metody $7 D008163
650    _2
$a průtoková injekční analýza $7 D017022
650    _2
$a oxidace-redukce $7 D010084
650    _2
$a léčivé přípravky $x analýza $7 D004364
650    _2
$a financování organizované $7 D005381
655    _2
$a přehledy $7 D016454
700    1_
$a Polášek, Miroslav, $d 1947- $7 xx0063895
700    1_
$a Martinez, Calatayud Jose
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $g Roč. 45, č. 3 (2007), s. 367-381 $x 0731-7085
910    __
$a ABA008 $b x $y 7
990    __
$a 20101116103302 $b ABA008
991    __
$a 20101213153053 $b ABA008
999    __
$a ok $b bmc $g 801412 $s 666158
BAS    __
$a 3
BMC    __
$a 2007 $b 45 $c 3 $d 367-381 $i 0731-7085 $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a 2010-B/jtme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...