Biomechanical testing of spinal segment fixed by thoracolumbar spine locking plate on the swine lumbar spine

Jan Kocis, Tomas Navrat, Zdenek Florian, Peter Wendsche

Jazyk angličtina Země Česko

Typ dokumentu srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc11002190

Background. The aim of the experiment was to compare the mechanical properties of intact spinal segment with impaired intervertebral disc and impaired intervertebral disc fixed by TSLP (Thoracolumbar Spine Locking Plate). Methods and results. Spinal specimens were taken from domestic swine. A total of 8 test mechanical states (intact, impaired and fixed) were modeled and the mechanical properties, expressed by the value of moment of couple necessary to twist the specimen at tensile force F = 200 N and the value of moments necessary for extension straining, were determined. The study was based on in vitro biomechanical testing of the TSLP plate used to stabilize the front thoracolumbar column of spinal segments taken from a pig. The plate was used for monosegmental fixation. The disc was cut by scalpel to simulate the Type A injury to front spinal column. In each state (intact, impaired or fixed), specimens were subjected to a tension load of prescribed force and, then, twisted by a given angle. Subsequently, extension load of intact, impaired and impaired & fixed segment was measured. Statistical evaluation verified the hypothesis of the different behavior of intact, impaired and fixed specimens – both for tension & torsion load and extension load. The analyses did not indicate different mechanical behavior of intact and fixed specimens. In other words, monosegmental fixation of both impaired and intact specimens by TSLP Synthes implant will lead to similar mechanical behavior of these specimens. Further, we found that intact and fixed specimens show non-symmetric behavior at positive and negative twisting angles. This was not observed for impaired specimens. Conclusion. Several stabilization systems were developed to stabilize the front thoracolumbar spinal column. Surgery of the anterior column of injured spine should restore the correct position of the spine, ensure decompression of vertebral canal when neural structures are compressed, and stabilize the spine to allow immediate loading and mobilization of the patient. The aim of this study was to compare mechanical properties of intact spinal segment, impaired spinal segment and impaired spinal segment stabilized by TSLP Synthes implant. The problems were solved by experimental modeling using a testing machine that simulated loads for several mechanical states of the spinal segment. Favorable mechanical properties of TSLP Synthes fixator were demonstrated. The experimental results will be used for subsequent computational modeling of the spinal segment in all experimentally solved states.

Citace poskytuje Crossref.org

Bibliografie atd.

Lit.: 13

000      
00000naa 2200000 a 4500
001      
bmc11002190
003      
CZ-PrNML
005      
20111210201944.0
008      
110221s2010 xr e eng||
009      
AR
024    7_
$a 10.5507/bp.2010.052 $2 doi
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Kočiš, Ján $7 xx0081819
245    10
$a Biomechanical testing of spinal segment fixed by thoracolumbar spine locking plate on the swine lumbar spine / $c Jan Kocis, Tomas Navrat, Zdenek Florian, Peter Wendsche
314    __
$a Department of Traumatology, Faculty of Medicine, Masaryk University, Brno
504    __
$a Lit.: 13
520    9_
$a Background. The aim of the experiment was to compare the mechanical properties of intact spinal segment with impaired intervertebral disc and impaired intervertebral disc fixed by TSLP (Thoracolumbar Spine Locking Plate). Methods and results. Spinal specimens were taken from domestic swine. A total of 8 test mechanical states (intact, impaired and fixed) were modeled and the mechanical properties, expressed by the value of moment of couple necessary to twist the specimen at tensile force F = 200 N and the value of moments necessary for extension straining, were determined. The study was based on in vitro biomechanical testing of the TSLP plate used to stabilize the front thoracolumbar column of spinal segments taken from a pig. The plate was used for monosegmental fixation. The disc was cut by scalpel to simulate the Type A injury to front spinal column. In each state (intact, impaired or fixed), specimens were subjected to a tension load of prescribed force and, then, twisted by a given angle. Subsequently, extension load of intact, impaired and impaired & fixed segment was measured. Statistical evaluation verified the hypothesis of the different behavior of intact, impaired and fixed specimens – both for tension & torsion load and extension load. The analyses did not indicate different mechanical behavior of intact and fixed specimens. In other words, monosegmental fixation of both impaired and intact specimens by TSLP Synthes implant will lead to similar mechanical behavior of these specimens. Further, we found that intact and fixed specimens show non-symmetric behavior at positive and negative twisting angles. This was not observed for impaired specimens. Conclusion. Several stabilization systems were developed to stabilize the front thoracolumbar spinal column. Surgery of the anterior column of injured spine should restore the correct position of the spine, ensure decompression of vertebral canal when neural structures are compressed, and stabilize the spine to allow immediate loading and mobilization of the patient. The aim of this study was to compare mechanical properties of intact spinal segment, impaired spinal segment and impaired spinal segment stabilized by TSLP Synthes implant. The problems were solved by experimental modeling using a testing machine that simulated loads for several mechanical states of the spinal segment. Favorable mechanical properties of TSLP Synthes fixator were demonstrated. The experimental results will be used for subsequent computational modeling of the spinal segment in all experimentally solved states.
650    _2
$a financování organizované $7 D005381
650    _2
$a zvířata $7 D000818
650    _2
$a biomechanika $7 D001696
650    _2
$a kostní destičky $7 D001860
650    _2
$a meziobratlová ploténka $7 D007403
650    _2
$a bederní obratle $x chirurgie $7 D008159
650    _2
$a nemoci páteře $x chirurgie $x patofyziologie $7 D013122
650    _2
$a hrudní obratle $7 D013904
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Návrat, Tomáš. $7 mzk2005279266
700    1_
$a Florian, Zdeněk, $d 1951- $7 jn19981001193
700    1_
$a Wendsche, Peter, $d 1945- $7 mzk2002103163
773    0_
$w MED00012606 $t Biomedical papers $g Roč. 154, č. 4 (2010), s. 345-354 $x 1213-8118
856    41
$u http://biomed.papers.upol.cz/pdfs/bio/2010/04/12.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 1502 $c 958 $y 2
990    __
$a 20110219071424 $b ABA008
991    __
$a 20110725122119 $b ABA008
999    __
$a ok $b bmc $g 829460 $s 694146
BAS    __
$a 3
BMC    __
$a 2010 $b 154 $c 4 $d 345-354 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $x MED00012606
LZP    __
$a 2011-11/ipme

Najít záznam

Citační ukazatele

Nahrávání dat ...