Je něco špatně v tomto záznamu ?
Evaluation of biaxial tension tests of soft tissues
J. Bursa, M. Zemanek
Jazyk angličtina Země Nizozemsko
Typ dokumentu hodnotící studie
NLK
Medline Complete (EBSCOhost)
od 2005-01-01 do Před 1 rokem
- MeSH
- arterie fyziologie MeSH
- biomechanika MeSH
- elastická tkáň fyziologie MeSH
- mechanický stres MeSH
- pevnost v tahu MeSH
- počítačová simulace MeSH
- pojivová tkáň fyziologie MeSH
- prasata MeSH
- pružnost MeSH
- statistické modely MeSH
- teoretické modely MeSH
- testování materiálů MeSH
- zobrazování trojrozměrné MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- hodnotící studie MeSH
Soft tissues are pseudoelastic anisotropic materials; various formulas for their strain energy density have been proposed for modelling of their constitutive behaviour. However, the individual variance of elastic parameters is often more pronounced than their anisotropy, so that their constitutive relations can be modelled as either isotropic or orthotropic. Any hyperelastic model requires more mechanical tests to be input for an identification of its parameters than mere uniaxial tension tests; especially biaxial tension tests are very important also for isotropic hyperelastic materials. A design of a testing rig produced in cooperation of our institute with some local companies is presented. It enables us to carry out not only equibiaxial tension tests, but also some other biaxial tensile tests, because displacements in both mutually perpendicular directions can be controlled independently. The proposal of various types of biaxial tests is presented in the paper, with examples of their realization with porcine aortic wall tissue. The contribution focuses on ways of evaluation of the results and on identification of parameters of various constitutive models. The use of more mechanical tests in identification of constitutive parameters can improve the predictive capability of the models substantially.
- 000
- 02702naa 2200385 a 4500
- 001
- bmc11003242
- 003
- CZ-PrNML
- 005
- 20241008090314.0
- 008
- 110225s2008 ne e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Burša, Jiří, $d 1954- $7 xx0034888
- 245 10
- $a Evaluation of biaxial tension tests of soft tissues / $c J. Bursa, M. Zemanek
- 314 __
- $a Institute of Solid Mechanics, Mechatronics and Biomechanics, FME, BUT, Brno, Czech Republic. bursa@fme.vutbr.cz
- 520 9_
- $a Soft tissues are pseudoelastic anisotropic materials; various formulas for their strain energy density have been proposed for modelling of their constitutive behaviour. However, the individual variance of elastic parameters is often more pronounced than their anisotropy, so that their constitutive relations can be modelled as either isotropic or orthotropic. Any hyperelastic model requires more mechanical tests to be input for an identification of its parameters than mere uniaxial tension tests; especially biaxial tension tests are very important also for isotropic hyperelastic materials. A design of a testing rig produced in cooperation of our institute with some local companies is presented. It enables us to carry out not only equibiaxial tension tests, but also some other biaxial tensile tests, because displacements in both mutually perpendicular directions can be controlled independently. The proposal of various types of biaxial tests is presented in the paper, with examples of their realization with porcine aortic wall tissue. The contribution focuses on ways of evaluation of the results and on identification of parameters of various constitutive models. The use of more mechanical tests in identification of constitutive parameters can improve the predictive capability of the models substantially.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a arterie $x fyziologie $7 D001158
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a pojivová tkáň $x fyziologie $7 D003238
- 650 _2
- $a elastická tkáň $x fyziologie $7 D004547
- 650 _2
- $a pružnost $7 D004548
- 650 _2
- $a zobrazování trojrozměrné $7 D021621
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a statistické modely $7 D015233
- 650 _2
- $a teoretické modely $7 D008962
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a pevnost v tahu $7 D013718
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Zemánek, Miroslav. $7 ola2011620338
- 773 0_
- $t Studies in health technology and informatics $w MED00180836 $g Roč. 133 (2008), s. 45-55 $x 0926-9630
- 910 __
- $a ABA008 $b x $y 7 $z 0
- 990 __
- $a 20110413120006 $b ABA008
- 991 __
- $a 20241008090311 $b ABA008
- 999 __
- $a ok $b bmc $g 830595 $s 695235
- BAS __
- $a 3
- BMC __
- $a 2008 $b 133 $d 45-55 $i 0926-9630 $m Studies in health technology and informatics $n Stud Health Technol Inform $x MED00180836
- LZP __
- $a 2011-2B/ipme