Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts
J Starcukova, Z Jr Starcuk, H Hubalkova, I Linetskiy
Jazyk angličtina Země Velká Británie
Grantová podpora
NR8110
MZ0
CEP - Centrální evidence projektů
- MeSH
- artefakty MeSH
- celotělové zobrazování přístrojové vybavení MeSH
- elektrická vodivost MeSH
- fantomy radiodiagnostické MeSH
- financování organizované MeSH
- krk anatomie a histologie MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody přístrojové vybavení MeSH
- magnetismus MeSH
- měď chemie MeSH
- mozek anatomie a histologie MeSH
- nikl chemie MeSH
- obličej anatomie a histologie MeSH
- slitiny chromu chemie MeSH
- slitiny zlata chemie MeSH
- sloučeniny hliníku chemie MeSH
- testování materiálů MeSH
- titan chemie MeSH
- ústa anatomie a histologie MeSH
- zubní amalgam chemie MeSH
- zubní slitiny chemie MeSH
- Check Tag
- lidé MeSH
OBJECTIVES: The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters-magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. METHODS: Magnetic susceptibility, electrical conductivity and artifacts were evaluated for 45 standardized cylindrical samples of dental alloys and amalgams. Magnetic susceptibility was determined by fitting the phase of gradient-echo MR images to numerically modeled data. Electrical conductivity was determined by standard electrotechnical measurements. Artifact sizes were measured in spin-echo (SE) and gradient-echo (GE) images at 1.5T according to the standards of the American Society for Testing and Materials. RESULTS: It has been confirmed that dental materials differ considerably in their magnetic susceptibility, electrical conductivity and artifacts. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel-chromium and cobalt-chromium artifacts were found still acceptable, but large restorations of aluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible. SIGNIFICANCE: MR imaging is possible even close to dental devices if they are made of dental materials with low magnetic susceptibility. Not all materials in current use meet this requirement.
Citace poskytuje Crossref.org
- 000
- 02332naa 2200505 a 4500
- 001
- bmc11003708
- 003
- CZ-PrNML
- 005
- 20160519100951.0
- 008
- 110302s2008 xxk e eng||
- 009
- AR
- 024 __
- $a 10.1016/j.dental.2007.07.002 $2 doi
- 035 __
- $a (PubMed)17884157
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Starčuková, Jana $7 xx0081879
- 245 10
- $a Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts / $c J Starcukova, Z Jr Starcuk, H Hubalkova, I Linetskiy
- 314 __
- $a Institute of Scientific Instruments of the ASCR, v.v.i., Academy of Sciences of the Czech Republic, Kralovopolska 147, 612 64 Brno, Czech Republic. jana@isibrno.cz
- 520 9_
- $a OBJECTIVES: The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters-magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. METHODS: Magnetic susceptibility, electrical conductivity and artifacts were evaluated for 45 standardized cylindrical samples of dental alloys and amalgams. Magnetic susceptibility was determined by fitting the phase of gradient-echo MR images to numerically modeled data. Electrical conductivity was determined by standard electrotechnical measurements. Artifact sizes were measured in spin-echo (SE) and gradient-echo (GE) images at 1.5T according to the standards of the American Society for Testing and Materials. RESULTS: It has been confirmed that dental materials differ considerably in their magnetic susceptibility, electrical conductivity and artifacts. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel-chromium and cobalt-chromium artifacts were found still acceptable, but large restorations of aluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible. SIGNIFICANCE: MR imaging is possible even close to dental devices if they are made of dental materials with low magnetic susceptibility. Not all materials in current use meet this requirement.
- 650 _2
- $a sloučeniny hliníku $x chemie $7 D017607
- 650 _2
- $a artefakty $7 D016477
- 650 _2
- $a mozek $x anatomie a histologie $7 D001921
- 650 _2
- $a slitiny chromu $x chemie $7 D002858
- 650 _2
- $a měď $x chemie $7 D003300
- 650 _2
- $a zubní slitiny $x chemie $7 D003722
- 650 _2
- $a zubní amalgam $x chemie $7 D003723
- 650 _2
- $a elektrická vodivost $7 D004553
- 650 _2
- $a obličej $x anatomie a histologie $7 D005145
- 650 _2
- $a slitiny zlata $x chemie $7 D006047
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonanční tomografie $x metody $x přístrojové vybavení $7 D008279
- 650 _2
- $a magnetismus $7 D008280
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a ústa $x anatomie a histologie $7 D009055
- 650 _2
- $a krk $x anatomie a histologie $7 D009333
- 650 _2
- $a nikl $x chemie $7 D009532
- 650 _2
- $a fantomy radiodiagnostické $7 D019047
- 650 _2
- $a titan $x chemie $7 D014025
- 650 _2
- $a celotělové zobrazování $x přístrojové vybavení $7 D051598
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Starčuk, Zenon, $d 1962- $7 xx0070830
- 700 1_
- $a Hubálková, Hana, $d 1958- $7 mzk2002157061
- 700 1_
- $a Linetskiy, Igor
- 773 0_
- $t Dental Materials $w MED00001334 $g Roč. 24, č. 6 (2008), s. 715-723 $x 0109-5641
- 910 __
- $a ABA008 $b x $y 7 $z 0
- 990 __
- $a 20110413121620 $b ABA008
- 991 __
- $a 20160519101103 $b ABA008
- 999 __
- $a ok $b bmc $g 831107 $s 695730
- BAS __
- $a 3
- BMC __
- $a 2008 $b 24 $c 6 $d 715-723 $i 0109-5641 $m Dental materials $n Dent Mater $x MED00001334
- GRA __
- $a NR8110 $p MZ0
- LZP __
- $a 2011-3B/vtme