Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts

J Starcukova, Z Jr Starcuk, H Hubalkova, I Linetskiy

. 2008 ; 24 (6) : 715-723.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc11003708

Grantová podpora
NR8110 MZ0 CEP - Centrální evidence projektů

OBJECTIVES: The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters-magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. METHODS: Magnetic susceptibility, electrical conductivity and artifacts were evaluated for 45 standardized cylindrical samples of dental alloys and amalgams. Magnetic susceptibility was determined by fitting the phase of gradient-echo MR images to numerically modeled data. Electrical conductivity was determined by standard electrotechnical measurements. Artifact sizes were measured in spin-echo (SE) and gradient-echo (GE) images at 1.5T according to the standards of the American Society for Testing and Materials. RESULTS: It has been confirmed that dental materials differ considerably in their magnetic susceptibility, electrical conductivity and artifacts. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel-chromium and cobalt-chromium artifacts were found still acceptable, but large restorations of aluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible. SIGNIFICANCE: MR imaging is possible even close to dental devices if they are made of dental materials with low magnetic susceptibility. Not all materials in current use meet this requirement.

Citace poskytuje Crossref.org

000      
02332naa 2200505 a 4500
001      
bmc11003708
003      
CZ-PrNML
005      
20160519100951.0
008      
110302s2008 xxk e eng||
009      
AR
024    __
$a 10.1016/j.dental.2007.07.002 $2 doi
035    __
$a (PubMed)17884157
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Starčuková, Jana $7 xx0081879
245    10
$a Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts / $c J Starcukova, Z Jr Starcuk, H Hubalkova, I Linetskiy
314    __
$a Institute of Scientific Instruments of the ASCR, v.v.i., Academy of Sciences of the Czech Republic, Kralovopolska 147, 612 64 Brno, Czech Republic. jana@isibrno.cz
520    9_
$a OBJECTIVES: The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters-magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. METHODS: Magnetic susceptibility, electrical conductivity and artifacts were evaluated for 45 standardized cylindrical samples of dental alloys and amalgams. Magnetic susceptibility was determined by fitting the phase of gradient-echo MR images to numerically modeled data. Electrical conductivity was determined by standard electrotechnical measurements. Artifact sizes were measured in spin-echo (SE) and gradient-echo (GE) images at 1.5T according to the standards of the American Society for Testing and Materials. RESULTS: It has been confirmed that dental materials differ considerably in their magnetic susceptibility, electrical conductivity and artifacts. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel-chromium and cobalt-chromium artifacts were found still acceptable, but large restorations of aluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible. SIGNIFICANCE: MR imaging is possible even close to dental devices if they are made of dental materials with low magnetic susceptibility. Not all materials in current use meet this requirement.
650    _2
$a sloučeniny hliníku $x chemie $7 D017607
650    _2
$a artefakty $7 D016477
650    _2
$a mozek $x anatomie a histologie $7 D001921
650    _2
$a slitiny chromu $x chemie $7 D002858
650    _2
$a měď $x chemie $7 D003300
650    _2
$a zubní slitiny $x chemie $7 D003722
650    _2
$a zubní amalgam $x chemie $7 D003723
650    _2
$a elektrická vodivost $7 D004553
650    _2
$a obličej $x anatomie a histologie $7 D005145
650    _2
$a slitiny zlata $x chemie $7 D006047
650    _2
$a lidé $7 D006801
650    _2
$a magnetická rezonanční tomografie $x metody $x přístrojové vybavení $7 D008279
650    _2
$a magnetismus $7 D008280
650    _2
$a testování materiálů $7 D008422
650    _2
$a ústa $x anatomie a histologie $7 D009055
650    _2
$a krk $x anatomie a histologie $7 D009333
650    _2
$a nikl $x chemie $7 D009532
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a titan $x chemie $7 D014025
650    _2
$a celotělové zobrazování $x přístrojové vybavení $7 D051598
650    _2
$a financování organizované $7 D005381
700    1_
$a Starčuk, Zenon, $d 1962- $7 xx0070830
700    1_
$a Hubálková, Hana, $d 1958- $7 mzk2002157061
700    1_
$a Linetskiy, Igor
773    0_
$t Dental Materials $w MED00001334 $g Roč. 24, č. 6 (2008), s. 715-723 $x 0109-5641
910    __
$a ABA008 $b x $y 7 $z 0
990    __
$a 20110413121620 $b ABA008
991    __
$a 20160519101103 $b ABA008
999    __
$a ok $b bmc $g 831107 $s 695730
BAS    __
$a 3
BMC    __
$a 2008 $b 24 $c 6 $d 715-723 $i 0109-5641 $m Dental materials $n Dent Mater $x MED00001334
GRA    __
$a NR8110 $p MZ0
LZP    __
$a 2011-3B/vtme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...