302 stran : grafy, tabulky ; 23 cm
Wilson disease (WD) primarily presents with hepatic and neurological symptoms. While hepatic symptoms typically precede the neurological manifestations, copper accumulates in the brain already in this patient group and leads to subclinical brain MRI abnormalities including T2 hyperintensities and atrophy. This study aimed to assess brain morphological changes in mild hepatic WD. WD patients without a history of neurologic symptoms and decompensated cirrhosis and control participants underwent brain MRI at 3T scanner including high-resolution T1-weighted images. A volumetric evaluation was conducted on the following brain regions: nucleus accumbens, caudate, pallidum, putamen, thalamus, amygdala, hippocampus, midbrain, pons, cerebellar gray matter, white matter (WM), and superior peduncle, using Freesurfer v7 software. Whole-brain analyses using voxel- and surface-based morphometry were performed using SPM12. Statistical comparisons utilized a general linear model adjusted for total intracranial volume, age, and sex. Twenty-six WD patients with mild hepatic form (30 ± 9 years [mean age ± SD]); 11 women; mean treatment duration 13 ± 12 (range 0-42) years and 28 healthy controls (33 ± 9 years; 15 women) were evaluated. Volumetric analysis revealed a significantly smaller pons volume and a trend for smaller midbrain and cerebellar WM in WD patients compared to controls. Whole-brain analysis revealed regions of reduced volume in the pons, cerebellar, and lobar WM in the WD group. No significant differences in gray matter density or cortical thickness were found. Myelin or WM in general seems vulnerable to low-level copper toxicity, with WM volume loss showing promise as a marker for assessing brain involvement in early WD stages.
- MeSH
- bílá hmota patologie diagnostické zobrazování MeSH
- dospělí MeSH
- hepatolentikulární degenerace * patologie diagnostické zobrazování MeSH
- játra patologie diagnostické zobrazování MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie * MeSH
- mladý dospělý MeSH
- mozek * patologie diagnostické zobrazování MeSH
- šedá hmota patologie diagnostické zobrazování MeSH
- studie případů a kontrol MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
PURPOSE OF REVIEW: Upper tract urothelial carcinoma (UTUC) is a rare malignancy posing significant diagnostic and management challenges. This review provides an overview of the evidence supporting various imaging modalities and offers insights into future innovations in UTUC imaging. RECENT FINDINGS: With the growing use of advancements in computed tomography (CT) technologies for both staging and follow-up of UTUC patients, continuous innovations aim to enhance performance and minimize the risk of excessive exposure to ionizing radiation and iodinated contrast medium. In patients unable to undergo CT, magnetic resonance imaging serves as an alternative imaging modality, though its sensitivity is lower than CT. Positron emission tomography, particularly with innovative radiotracers and theranostics, has the potential to significantly advance precision medicine in UTUC. Endoscopic imaging techniques including advanced modalities seem to be promising in improved visualization and diagnostic accuracy, however, evidence remains scarce. Radiomics and radiogenomics present emerging tools for noninvasive tumor characterization and prognosis. SUMMARY: The landscape of imaging for UTUC is rapidly evolving, with significant advancements across various modalities promising improved diagnostic accuracy, patient outcomes, and safety.
- MeSH
- karcinom z přechodných buněk * diagnóza diagnostické zobrazování terapie patologie MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- nádory ledvin diagnostické zobrazování terapie diagnóza patologie MeSH
- nádory močovodu diagnostické zobrazování diagnóza terapie patologie MeSH
- počítačová rentgenová tomografie metody MeSH
- pozitronová emisní tomografie metody MeSH
- staging nádorů MeSH
- urologické nádory diagnóza diagnostické zobrazování terapie patologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
PURPOSE: The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts. METHODS: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects. RESULTS: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative T2*$$ {\mathrm{T}}_2^{\ast } $$ relaxometry analyses. CONCLUSION: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.
- MeSH
- algoritmy * MeSH
- artefakty * MeSH
- fantomy radiodiagnostické * MeSH
- kalibrace MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačové zpracování obrazu * metody MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Dual velocity encoding PC-MRI can produce spurious artifacts when using high ratios of velocity encoding values (VENCs), limiting its ability to generate high-quality images across a wide range of encoding velocities. This study aims to propose and compare dual-VENC correction methods for such artifacts. THEORY AND METHODS: Two denoising approaches based on spatiotemporal regularization are proposed and compared with a state-of-the-art method based on sign correction. Accuracy is assessed using simulated data from an aorta and brain aneurysm, as well as 8 two-dimensional (2D) PC-MRI ascending aorta datasets. Two temporal resolutions (30,60) ms and noise levels (9,12) dB are considered, with noise added to the complex magnetization. The error is evaluated with respect to the noise-free measurement in the synthetic case and to the unwrapped image without additional noise in the volunteer datasets. RESULTS: In all studied cases, the proposed methods are more accurate than the Sign Correction technique. Using simulated 2D+T data from the aorta (60 ms, 9 dB), the Dual-VENC (DV) error 0.82±0.07$$ 0.82\pm 0.07 $$ is reduced to: 0.66±0.04$$ 0.66\pm 0.04 $$ (Sign Correction); 0.34±0.04$$ 0.34\pm 0.04 $$ and 0.32±0.04$$ 0.32\pm 0.04 $$ (proposed techniques). The methods are found to be significantly different (p-value <0.05$$ <0.05 $$ ). Importantly, brain aneurysm data revealed that the Sign Correction method is not suitable, as it increases error when the flow is not unidirectional. All three methods improve the accuracy of in vivo data. CONCLUSION: The newly proposed methods outperform the Sign Correction method in improving dual-VENC PC-MRI images. Among them, the approach based on temporal differences has shown the highest accuracy.
- MeSH
- algoritmy * MeSH
- aorta * diagnostické zobrazování MeSH
- artefakty * MeSH
- fantomy radiodiagnostické MeSH
- interpretace obrazu počítačem metody MeSH
- intrakraniální aneurysma diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačová simulace MeSH
- počítačové zpracování obrazu * metody MeSH
- poměr signál - šum * MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND PURPOSE: Cognitive impairment (CI) in multiple sclerosis (MS) is associated with bidirectional changes in resting-state centrality measures. However, practicable functional magnetic resonance imaging (fMRI) biomarkers of CI are still lacking. The aim of this study was to assess the graph-theory-based degree rank order disruption index (kD) and its association with cognitive processing speed as a marker of CI in patients with MS (PwMS) in a secondary cross-sectional fMRI analysis. METHODS: Differentiation between PwMS and healthy controls (HCs) using kD and its correlation with CI (Symbol Digit Modalities Test) was compared to established imaging biomarkers (regional degree, volumetry, diffusion-weighted imaging, lesion mapping). Additional associations were assessed for fatigue (Fatigue Scale for Motor and Cognitive Functions), gait and global disability. RESULTS: Analysis in 56 PwMS and 58 HCs (35/27 women, median age 45.1/40.5 years) showed lower kD in PwMS than in HCs (median -0.30/-0.06, interquartile range 0.55/0.54; p = 0.009, Mann-Whitney U test), yielding acceptable yet non-superior differentiation (area under curve 0.64). kD and degree in medial prefrontal cortex (MPFC) correlated with CI (kD/MPFC Spearman's ρ = 0.32/-0.45, p = 0.019/0.001, n = 55). kD also explained fatigue (ρ = -0.34, p = 0.010, n = 56) but neither gait nor disability. CONCLUSIONS: kD is a potential biomarker of CI and fatigue warranting further validation.
- MeSH
- dospělí MeSH
- kognitivní dysfunkce etiologie patofyziologie diagnostické zobrazování MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie * MeSH
- průřezové studie MeSH
- roztroušená skleróza * komplikace diagnostické zobrazování patofyziologie MeSH
- rychlost zpracování MeSH
- únava * patofyziologie etiologie diagnostické zobrazování MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous noninvasive acquisition of MR spectra from multiple spatial locations inside the brain. Although 1H-MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical setting, mostly because of difficulties specifically related to very small nominal voxel size in the rat brain and low concentration of brain metabolites, resulting in low signal-to-noise ratio (SNR). In this context, we implemented a free induction decay 1H-MRSI sequence (1H-FID-MRSI) in the rat brain at 14.1 T. We combined the advantages of 1H-FID-MRSI with the ultra-high magnetic field to achieve higher SNR, coverage, and spatial resolution in the rat brain and developed a custom dedicated processing pipeline with a graphical user interface for Bruker 1H-FID-MRSI: MRS4Brain toolbox. LCModel fit, using the simulated metabolite basis set and in vivo measured MM, provided reliable fits for the data at acquisition delays of 1.30 ms. The resulting Cramér-Rao lower bounds were sufficiently low (< 30%) for eight metabolites of interest (total creatine, N-acetylaspartate, N-acetylaspartate + N-acetylaspartylglutamate, total choline, glutamine, glutamate, myo-inositol, and taurine), leading to highly reproducible metabolic maps. Similar spectral quality and metabolic maps were obtained with one and two averages, with slightly better contrast and brain coverage due to increased SNR in the latter case. Furthermore, the obtained metabolic maps were accurate enough to confirm the previously known brain regional distribution of some metabolites. The acquisitions proved high reproducibility over time. We demonstrated that the increased SNR and spectral resolution at 14.1 T can be translated into high spatial resolution in 1H-FID-MRSI of the rat brain in 13 min using the sequence and processing pipeline described herein. High-resolution 1H-FID-MRSI at 14.1 T provided robust, reproducible, and high-quality metabolic mapping of brain metabolites with minimal technical limitations.
- MeSH
- krysa rodu rattus MeSH
- magnetická rezonanční tomografie metody MeSH
- metabolom MeSH
- mozek * metabolismus diagnostické zobrazování MeSH
- poměr signál - šum MeSH
- potkani Sprague-Dawley MeSH
- potkani Wistar MeSH
- protonová magnetická rezonanční spektroskopie metody MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Alterations in tricarboxylic acid (TCA) cycle metabolism are associated with hepatic metabolic disorders. Elevated hepatic acetate concentrations, often attributed to high caloric intake, are recognized as a pivotal factor in the etiology of obesity and metabolic syndrome. Therefore, the assessment of acetate breakdown and TCA cycle activity plays a central role in understanding the impact of diet-induced alterations on liver metabolism. Magnetic resonance-based deuterium metabolic imaging (DMI) could help to unravel the underlying mechanisms involved in disease development and progression, however, the application of conventional deuterated glucose does not lead to substantial enrichment in hepatic glutamine and glutamate. This study aimed to demonstrate the feasibility of DMI for tracking deuterated acetate breakdown via the TCA cycle in lean and diet-induced fatty liver (FL) rats using 3D DMI after an intraperitoneal infusion of sodium acetate-d3 at 9.4T. Localized and nonlocalized liver spectra acquired at 10 time points post-injection over a 130-min study revealed similar intrahepatic acetate uptake in both animal groups (AUCFL = 717.9 ± 131.1 mM▯min-1, AUClean = 605.1 ± 119.9 mM▯min-1, p = 0.62). Metabolic breakdown could be observed in both groups with an emerging glutamine/glutamate (Glx) peak as a downstream metabolic product (AUCFL = 113.6 ± 23.8 mM▯min-1, AUClean = 136.7 ± 41.7 mM▯min-1, p = 0.68). This study showed the viability of DMI for tracking substrate flux through the TCA cycle, underscoring its methodological potential for imaging metabolic processes in the body.
- MeSH
- acetáty metabolismus MeSH
- analýza metabolického toku MeSH
- citrátový cyklus * MeSH
- deuterium * MeSH
- játra * metabolismus diagnostické zobrazování MeSH
- krysa rodu rattus MeSH
- magnetická rezonanční tomografie MeSH
- potkani Sprague-Dawley MeSH
- potkani Wistar MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Ageing is a complex phenomenon affecting a wide range of coexisting biological processes. The homogeneity of the studied population is an essential parameter for valid interpretations of outcomes. The presented study capitalises on the MRI data available in the Human Connectome Project-Aging (HCP-A) and, within individuals over 55 years of age who passed the HCP-A section criteria, compares a subgroup of 37 apparently neurocognitively healthy individuals selected based on stringent criteria with 37 age and sex-matched individuals still representative of typical ageing but who did not pass the stringent definition of neurocognitively healthy. Specifically, structural scans, diffusion weighted imaging and T1w/T2w ratio were utilised. Furthermore, data of 26 HCP-A participants older than 90 years as notional 'super-agers' were analysed. The relationship of age and several microstructural MRI metrics (T1w/T2w ratio, mean diffusivity, intracellular volume fraction and free water volume fraction) differed significantly between typical and healthy ageing cohort in areas highly relevant for ageing such as hippocampus, prefrontal and temporal cortex and cerebellum. However, the trajectories of the healthy ageing population did not show substantially better overlap with the findings in people older than 90 than those of the typical population. Therefore, caution must be exercised in the choice of adequate study group characteristics relevant for respective ageing-related hypotheses. Contrary to typical ageing group, the healthy ageing cohort may show generally stable levels of several MRI metrics of interest.
- MeSH
- kognice * fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mozek diagnostické zobrazování MeSH
- šedá hmota * diagnostické zobrazování MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- stárnutí * fyziologie MeSH
- zdravé stárnutí fyziologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
A case report of a 68-year-old otherwise-healthy female patient with Spetzler-Martin (SM) grade I arteriovenous malformation (AVM) in her left frontal region is presented. After an uneventful surgery, cerebral venous infarction developed, and the patient was rendered hemiparetic with motor aphasia. After bony decompression, slow improvement was seen, and 3 months after surgery, the patient was neurologically intact. Six months after AVM resection, cranioplasty was performed. Infarction was caused by the thrombosis of a long primary draining vein, which finished its course in the normal cortical venous system. The case supports the venous origin of postoperative bleeding after AVM resection instead of the normal perfusion pressure phenomenon.
- MeSH
- cerebrální infarkt * etiologie chirurgie MeSH
- intrakraniální arteriovenózní malformace * chirurgie komplikace MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mozkové žíly chirurgie diagnostické zobrazování MeSH
- pooperační komplikace etiologie chirurgie MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH