Rapid and precise method for the determination of 8-iso-prostaglandin F(2alpha), an essential marker of the oxidative stress, in exhaled breath condensate (EBC) was developed. The protocol consisted of stable isotope dilution, immunoseparation combined with selective and sensitive LC-ESI-MS/MS operated in multiple reaction monitoring (MRM) mode. The imprecision of the developed method was below 8.8%, the parameter of mean inaccuracy was determined as <9.6% (0-250pg of 8-iso-prostaglandin F(2alpha)/ml EBC). The limit of detection (LOD) was 1 pg/ml EBC and limit of quantification (LOQ) 5 pg/ml EBC. A significant difference in 8-iso-prostaglandin F(2alpha) content between the group of asbestosis patients and healthy volunteers was found.

000      
02463naa 2200397 a 4500
001      
bmc11003842
003      
CZ-PrNML
005      
20130925144556.0
008      
110302s2008 ne e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Syslová, Kamila $7 xx0145898
245    10
$a Determination of 8-iso-prostaglandin F(2alpha) in exhaled breath condensate using combination of immunoseparation and LC-ESI-MS/MS / $c K Syslova, P Kacer, M Kuzma, P Klusackova, Z Fenclova, J Lebedova, D Pelclova
314    __
$a Institute of Chemical Technology, Technicka 5, 166 28 Prague 6, Czech Republic.
520    9_
$a Rapid and precise method for the determination of 8-iso-prostaglandin F(2alpha), an essential marker of the oxidative stress, in exhaled breath condensate (EBC) was developed. The protocol consisted of stable isotope dilution, immunoseparation combined with selective and sensitive LC-ESI-MS/MS operated in multiple reaction monitoring (MRM) mode. The imprecision of the developed method was below 8.8%, the parameter of mean inaccuracy was determined as <9.6% (0-250pg of 8-iso-prostaglandin F(2alpha)/ml EBC). The limit of detection (LOD) was 1 pg/ml EBC and limit of quantification (LOQ) 5 pg/ml EBC. A significant difference in 8-iso-prostaglandin F(2alpha) content between the group of asbestosis patients and healthy volunteers was found.
650    _2
$a dechové testy $7 D001944
650    _2
$a kalibrace $7 D002138
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a dinoprost $x analogy a deriváty $x analýza $7 D015237
650    _2
$a lidé $7 D006801
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a financování organizované $7 D005381
655    _2
$a validační studie $7 D023361
700    1_
$a Kačer, Petr, $d 1969- $7 xx0081992
700    1_
$a Kuzma, Marek, $d 1974- $7 xx0075964
700    1_
$a Klusáčková, Pavlína $7 xx0081991
700    1_
$a Fenclová, Zdeňka $7 xx0074215
700    1_
$a Lebedová, Jindřiška $7 xx0062564
700    1_
$a Pelclová, Daniela, $d 1953- $7 nlk20010096163
773    0_
$t Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences $w MED00006642 $g Roč. 867, č. 1 (2008), s. 8-14 $x 1570-0232
910    __
$a ABA008 $b x $y 6
990    __
$a 20110405094404 $b ABA008
991    __
$a 20130925145104 $b ABA008
999    __
$a ok $b bmc $g 831186 $s 695866
BAS    __
$a 3
BMC    __
$a 2008 $b 867 $c 1 $d 8-14 $i 1570-0232 $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
GRA    __
$a NR8107 $p MZ0
LZP    __
$a 2011-3B/irme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...