• Something wrong with this record ?

Titania-based stationary phase in separation of ondansetron and its related compounds

V. Žižkovský, R. Kučera, J. Klimeš, J. Dohnal

Language English Country Netherlands

Improvements in stationary phase stability have been and remain a great task for research of new stationary phases. Metal oxide-based stationary phases appear as one of perspective alternatives to classical silica based stationary phases regarding to their similar effectiveness, different selectivity, different retention mechanism and mainly better chemical and thermal stability. In this study, the retention behaviour of ondansetron and its five pharmacopoeial impurities on TiO(2)-based reversed phase was investigated. The influence of buffer type, pH and concentration on retention was studied. Different types and amount of organic solvent in mobile phase were tested. The effect of temperature and flow rate on separation was investigated. The separation conditions were optimized and developed method validated. The retention parameters - retention time (t(R)), retention factor (k'), theoretical plate number (N), resolution between peaks due to nearby peaks (R(s)) and symmetry factor (A(s)) have been compared to parameters achieved on polybutadiene-coated zirconia column. The thermodynamic parameters of retention of analysed compounds - enthalpy, entropy and Gibbs free energy - were calculated and compared to those achieved on polybutadiene-coated zirconia column. This work proves similarity of retention behaviour of ondansetron and its five related compounds on zirconia-based and titania-based stationary phases and potential utilisation of polyethylene covered TiO(2)-based reversed stationary phase as an alternative to polybutadiene-coated ZrO(2) stationary phase in pharmaceutical analysis of ondansetron.

000      
02924naa 2200313 a 4500
001      
bmc11003846
003      
CZ-PrNML
005      
20120201064926.0
008      
110302s2008 ne e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Žižkovský, Václav. $7 xx0209119
245    10
$a Titania-based stationary phase in separation of ondansetron and its related compounds / $c V. Žižkovský, R. Kučera, J. Klimeš, J. Dohnal
314    __
$a Charles University in Prague, Faculty of Pharmacy in Hradec Kralove, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic.
520    9_
$a Improvements in stationary phase stability have been and remain a great task for research of new stationary phases. Metal oxide-based stationary phases appear as one of perspective alternatives to classical silica based stationary phases regarding to their similar effectiveness, different selectivity, different retention mechanism and mainly better chemical and thermal stability. In this study, the retention behaviour of ondansetron and its five pharmacopoeial impurities on TiO(2)-based reversed phase was investigated. The influence of buffer type, pH and concentration on retention was studied. Different types and amount of organic solvent in mobile phase were tested. The effect of temperature and flow rate on separation was investigated. The separation conditions were optimized and developed method validated. The retention parameters - retention time (t(R)), retention factor (k'), theoretical plate number (N), resolution between peaks due to nearby peaks (R(s)) and symmetry factor (A(s)) have been compared to parameters achieved on polybutadiene-coated zirconia column. The thermodynamic parameters of retention of analysed compounds - enthalpy, entropy and Gibbs free energy - were calculated and compared to those achieved on polybutadiene-coated zirconia column. This work proves similarity of retention behaviour of ondansetron and its five related compounds on zirconia-based and titania-based stationary phases and potential utilisation of polyethylene covered TiO(2)-based reversed stationary phase as an alternative to polybutadiene-coated ZrO(2) stationary phase in pharmaceutical analysis of ondansetron.
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a molekulární struktura $7 D015394
650    _2
$a ondansetron $x chemie $x izolace a purifikace $7 D017294
650    _2
$a titan $x chemie $7 D014025
650    _2
$a zirkonium $x chemie $7 D015040
650    _2
$a financování organizované $7 D005381
700    1_
$a Kučera, Radim $7 xx0128665
700    1_
$a Klimeš, Jiří, $d 1950- $7 jn20000710203
700    1_
$a Dohnal, Jiří, $d 1955- $7 xx0063747
773    0_
$t Journal of Chromatography. A $w MED00004962 $g Roč. 1189, č. 1-2 (2008), s. 83-91 $x 0021-9673
910    __
$a ABA008 $b x $y 6
990    __
$a 20110405102303 $b ABA008
991    __
$a 20120201064925 $b ABA008
999    __
$a ok $b bmc $g 831190 $s 695870
BAS    __
$a 3
BMC    __
$a 2008 $b 1189 $c 1-2 $d 83-91 $i 0021-9673 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a 2011-3B/irme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...