Srovnání otěrových charakteristik polyetylénu in vivo u náhrad kolena s kovovou a keramickou femorální komponentou
[Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement]
D. Veigl, P. Vavřík, D. Pokorný, M. Šlouf, E. Pavlova, I. Landor
Language Czech Country Czech Republic
Document type Comparative Study
Digital library NLK
Source
NLK
Free Medical Journals
from 2006
- MeSH
- Equipment Failure Analysis MeSH
- Ceramics MeSH
- Middle Aged MeSH
- Humans MeSH
- Polyethylenes MeSH
- Knee Prosthesis MeSH
- Foreign-Body Reaction etiology pathology MeSH
- Prosthesis Failure MeSH
- Aged MeSH
- Chromium Alloys MeSH
- Arthroplasty, Replacement, Knee MeSH
- Particle Size MeSH
- Zirconium MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Comparative Study MeSH
PURPOSE OF THE STUDY The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. MATERIAL AND METHODS Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. RESULTS In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. DISCUSSION One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching a real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface roughness between CoCrMo (Ra = 0.05) and ZrO2 (Ra = 0.02) components did not play any role in in vivo conditions. CONCLUSIONS In accordance with a previous clinical study, this evaluation of the quality and quantity of UHMWPE wear particles produced by a ceramic femoral component in vivo failed to demonstrate any advantage of zirconia ceramic components over the cobalt-chrome femoral components so far used.
Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement
Lit.: 49
- 000
- 00000naa 2200000 a 4500
- 001
- bmc11004180
- 003
- CZ-PrNML
- 005
- 20111210202555.0
- 008
- 110304s2011 xr e cze||
- 009
- AR
- 024 7_
- $2 doi $a 10.55095/achot2011/008
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Veigl, David $7 xx0143524
- 245 10
- $a Srovnání otěrových charakteristik polyetylénu in vivo u náhrad kolena s kovovou a keramickou femorální komponentou / $c D. Veigl, P. Vavřík, D. Pokorný, M. Šlouf, E. Pavlova, I. Landor
- 246 11
- $a Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement
- 314 __
- $a I. ortopedická klinika 1. LF UK a FN Motol, Praha
- 504 __
- $a Lit.: 49
- 520 9_
- $a PURPOSE OF THE STUDY The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. MATERIAL AND METHODS Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. RESULTS In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. DISCUSSION One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching a real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface roughness between CoCrMo (Ra = 0.05) and ZrO2 (Ra = 0.02) components did not play any role in in vivo conditions. CONCLUSIONS In accordance with a previous clinical study, this evaluation of the quality and quantity of UHMWPE wear particles produced by a ceramic femoral component in vivo failed to demonstrate any advantage of zirconia ceramic components over the cobalt-chrome femoral components so far used.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a totální endoprotéza kolene $7 D019645
- 650 _2
- $a keramika $7 D002516
- 650 _2
- $a slitiny chromu $7 D002858
- 650 _2
- $a analýza selhání vybavení $7 D019544
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a reakce na cizí těleso $x etiologie $x patologie $7 D005549
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a protézy kolene $7 D007720
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a velikost částic $7 D010316
- 650 _2
- $a polyethyleny $7 D011095
- 650 _2
- $a selhání protézy $7 D011475
- 650 _2
- $a zirkonium $7 D015040
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Vavřík, Pavel, $d 1951- $7 nlk19990073980
- 700 1_
- $a Pokorný, David, $d 1968- $7 jn20001103568
- 700 1_
- $a Šlouf, Miroslav, $d 1973- $7 xx0107048
- 700 1_
- $a Pavlova, Ewa $7 xx0140861
- 700 1_
- $a Landor, Ivan, $d 1956- $7 xx0062301
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca $g Roč. 78, č. 1 (2011), s. 49-55 $x 0001-5415
- 910 __
- $a ABA008 $b A 8 $c 507 $y 2
- 990 __
- $a 20110304091944 $b ABA008
- 991 __
- $a 20110726095526 $b ABA008
- 999 __
- $a ok $b bmc $g 831520 $s 696210
- BAS __
- $a 3
- BMC __
- $a 2011 $b 78 $c 1 $d 49-55 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x MED00011021
- LZP __
- $a 2011-15/vtme