• Je něco špatně v tomto záznamu ?

Measurement of cellular excitability by whole cell patch clamp technique

M. Karmažínová, Ľ. Lacinová

. 2010 ; 59 (Suppl. 1) : S1-S7.

Jazyk angličtina Země Česko

Typ dokumentu přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc11004378

Patch clamp method developed more than 30 years ago is widely used for investigation of cellular excitability manifested as transmembrane ionic current and/or generation of action potentials. This technique could be applied to measurement of ionic currents flowing through individual (single) ion channels or through the whole assembly of ion channels expressed in the whole cell. Whole cell configuration is more common for measurement of ion currents and the only one enabling measurement of action potentials. This method allows detailed analysis of mechanisms and structural determinants of voltagedependent gating of ion channels as well as regulation of channel activity by intracellular signaling pathways and pharmacological agents.

Citace poskytuje Crossref.org

Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010

Bibliografie atd.

Lit.: 6

000      
00000naa 2200000 a 4500
001      
bmc11004378
003      
CZ-PrNML
005      
20151006141945.0
008      
110308s2010 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.932000 $2 doi
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Karmažínová, M. $7 _AN058462
245    10
$a Measurement of cellular excitability by whole cell patch clamp technique / $c M. Karmažínová, Ľ. Lacinová
314    __
$a Slovak Academy of Sciences, Institute of Molecular Physiology and Genetics, Bratislava
500    __
$a Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010
504    __
$a Lit.: 6
520    9_
$a Patch clamp method developed more than 30 years ago is widely used for investigation of cellular excitability manifested as transmembrane ionic current and/or generation of action potentials. This technique could be applied to measurement of ionic currents flowing through individual (single) ion channels or through the whole assembly of ion channels expressed in the whole cell. Whole cell configuration is more common for measurement of ion currents and the only one enabling measurement of action potentials. This method allows detailed analysis of mechanisms and structural determinants of voltagedependent gating of ion channels as well as regulation of channel activity by intracellular signaling pathways and pharmacological agents.
650    _2
$a financování organizované $7 D005381
650    _2
$a akční potenciály $7 D000200
650    _2
$a zvířata $7 D000818
650    _2
$a vápníkové kanály - typ T $x metabolismus $7 D020747
650    _2
$a vápníková signalizace $7 D020013
650    _2
$a buněčná membrána $x metabolismus $7 D002462
650    _2
$a lidé $7 D006801
650    _2
$a gating iontového kanálu $7 D015640
650    _2
$a iontové kanály $x metabolismus $7 D007473
650    _2
$a membránové potenciály $7 D008564
650    _2
$a biologické modely $7 D008954
650    _2
$a metoda terčíkového zámku $7 D018408
655    _2
$a přehledy $7 D016454
700    1_
$a Lacinová, Ľubica, $d 1959- $7 xx0060119
773    0_
$w MED00003824 $t Physiological research $g Roč. 59,Suppl. 1 (2010), s. S1-S7 $x 0862-8408
773    0_
$t Methods in experimental and clinical cardiovascular research $g Roč. 59,Suppl. 1 (2010), s. S1-S7 $w MED00178497
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/59%20Suppl%201/59_S1.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 1 $z 0
990    __
$a 20110303103805 $b ABA008
991    __
$a 20151006142130 $b ABA008
999    __
$a ok $b bmc $g 831735 $s 696411
BAS    __
$a 3
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S1-S7 $m Physiological research $x MED00003824
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S1-S7 $m Methods in experimental and clinical cardiovascular research $x MED00178497
LZP    __
$a 2011-14/ipme

Najít záznam

Citační ukazatele

Nahrávání dat ...