Measurement of cellular excitability by whole cell patch clamp technique
M. Karmažínová, Ľ. Lacinová
Jazyk angličtina Země Česko
Typ dokumentu přehledy
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- akční potenciály MeSH
- biologické modely MeSH
- buněčná membrána metabolismus MeSH
- financování organizované MeSH
- gating iontového kanálu MeSH
- iontové kanály metabolismus MeSH
- lidé MeSH
- membránové potenciály MeSH
- metoda terčíkového zámku MeSH
- vápníková signalizace MeSH
- vápníkové kanály - typ T metabolismus MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- přehledy MeSH
Patch clamp method developed more than 30 years ago is widely used for investigation of cellular excitability manifested as transmembrane ionic current and/or generation of action potentials. This technique could be applied to measurement of ionic currents flowing through individual (single) ion channels or through the whole assembly of ion channels expressed in the whole cell. Whole cell configuration is more common for measurement of ion currents and the only one enabling measurement of action potentials. This method allows detailed analysis of mechanisms and structural determinants of voltagedependent gating of ion channels as well as regulation of channel activity by intracellular signaling pathways and pharmacological agents.
Citace poskytuje Crossref.org
Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010
Bibliografie atd.Lit.: 6
- 000
- 00000naa 2200000 a 4500
- 001
- bmc11004378
- 003
- CZ-PrNML
- 005
- 20151006141945.0
- 008
- 110308s2010 xr e eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.932000 $2 doi
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Karmažínová, M. $7 _AN058462
- 245 10
- $a Measurement of cellular excitability by whole cell patch clamp technique / $c M. Karmažínová, Ľ. Lacinová
- 314 __
- $a Slovak Academy of Sciences, Institute of Molecular Physiology and Genetics, Bratislava
- 500 __
- $a Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010
- 504 __
- $a Lit.: 6
- 520 9_
- $a Patch clamp method developed more than 30 years ago is widely used for investigation of cellular excitability manifested as transmembrane ionic current and/or generation of action potentials. This technique could be applied to measurement of ionic currents flowing through individual (single) ion channels or through the whole assembly of ion channels expressed in the whole cell. Whole cell configuration is more common for measurement of ion currents and the only one enabling measurement of action potentials. This method allows detailed analysis of mechanisms and structural determinants of voltagedependent gating of ion channels as well as regulation of channel activity by intracellular signaling pathways and pharmacological agents.
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a akční potenciály $7 D000200
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a vápníkové kanály - typ T $x metabolismus $7 D020747
- 650 _2
- $a vápníková signalizace $7 D020013
- 650 _2
- $a buněčná membrána $x metabolismus $7 D002462
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a gating iontového kanálu $7 D015640
- 650 _2
- $a iontové kanály $x metabolismus $7 D007473
- 650 _2
- $a membránové potenciály $7 D008564
- 650 _2
- $a biologické modely $7 D008954
- 650 _2
- $a metoda terčíkového zámku $7 D018408
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Lacinová, Ľubica, $d 1959- $7 xx0060119
- 773 0_
- $w MED00003824 $t Physiological research $g Roč. 59,Suppl. 1 (2010), s. S1-S7 $x 0862-8408
- 773 0_
- $t Methods in experimental and clinical cardiovascular research $g Roč. 59,Suppl. 1 (2010), s. S1-S7 $w MED00178497
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/59%20Suppl%201/59_S1.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 1 $z 0
- 990 __
- $a 20110303103805 $b ABA008
- 991 __
- $a 20151006142130 $b ABA008
- 999 __
- $a ok $b bmc $g 831735 $s 696411
- BAS __
- $a 3
- BMC __
- $a 2010 $b 59 $c Suppl. 1 $d S1-S7 $m Physiological research $x MED00003824
- BMC __
- $a 2010 $b 59 $c Suppl. 1 $d S1-S7 $m Methods in experimental and clinical cardiovascular research $x MED00178497
- LZP __
- $a 2011-14/ipme