Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Experimental methods for simultaneous measurement of action potentials and electrograms in isolated heart

J. Kolářová, K. Fialová, O. Janoušek, M. Nováková, I. Provazník

. 2010 ; 59 (Suppl. 1) : S71-S80.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc11004400

Monophasic action potential (MAP) can be recorded from the heart surface by optical method based on fluorescence measurement. The motion of isolated heart during experiment caused additional noise in recorded signal. The motion artifact can be eliminated by ratiometric fluorescence emission measurements. This study is based on experiments in which optical MAP measurement is done by single-wavelength and dualwavelength measurement of fluorescence emission. Both recording setups are presented and their advantages and disadvantages are discussed. MAPs recorded by both methods from isolated rabbit hearts perfused according to Langendorff are presented. Simultaneous electrograms (EG) and MAPs recording are analyzed and measurement of velocity of impulse conduction through heart tissue is presented.

Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010

Bibliografie atd.

Lit.: 32

000      
00000naa 2200000 a 4500
001      
bmc11004400
003      
CZ-PrNML
005      
20151006142054.0
008      
110308s2010 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.932010 $2 doi
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Kolářová, J. $7 _AN058469
245    10
$a Experimental methods for simultaneous measurement of action potentials and electrograms in isolated heart / $c J. Kolářová, K. Fialová, O. Janoušek, M. Nováková, I. Provazník
314    __
$a University of Technology, Department of Biomedical Engineering, Brno
500    __
$a Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010
504    __
$a Lit.: 32
520    9_
$a Monophasic action potential (MAP) can be recorded from the heart surface by optical method based on fluorescence measurement. The motion of isolated heart during experiment caused additional noise in recorded signal. The motion artifact can be eliminated by ratiometric fluorescence emission measurements. This study is based on experiments in which optical MAP measurement is done by single-wavelength and dualwavelength measurement of fluorescence emission. Both recording setups are presented and their advantages and disadvantages are discussed. MAPs recorded by both methods from isolated rabbit hearts perfused according to Langendorff are presented. Simultaneous electrograms (EG) and MAPs recording are analyzed and measurement of velocity of impulse conduction through heart tissue is presented.
650    _2
$a financování organizované $7 D005381
650    _2
$a akční potenciály $7 D000200
650    _2
$a zvířata $7 D000818
650    _2
$a artefakty $7 D016477
650    _2
$a elektrofyziologické techniky kardiologické $7 D022062
650    _2
$a fluorescence $7 D005453
650    _2
$a fluorescenční barviva $x diagnostické užití $7 D005456
650    _2
$a srdce $x fyziologie $7 D006321
650    _2
$a perfuze $7 D010477
650    _2
$a prediktivní hodnota testů $7 D011237
650    _2
$a králíci $7 D011817
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a počítačové zpracování signálu $7 D012815
650    _2
$a časové faktory $7 D013997
650    _2
$a techniky in vitro $7 D066298
700    1_
$a Fialová, Kateřina $7 xx0105137
700    1_
$a Janoušek, Oto. $7 mzk2014840916
700    1_
$a Nováková, Marie, $d 1965- $7 xx0006795
700    1_
$a Provazník, Ivo, $d 1968- $7 mzk2002106297
773    0_
$w MED00003824 $t Physiological research $g Roč. 59,Suppl. 1 (2010), s. S71-S80 $x 0862-8408
773    0_
$t Methods in experimental and clinical cardiovascular research $g Roč. 59,Suppl. 1 (2010), s. S71-S80 $w MED00178497
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/59%20Suppl%201/59_S71.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 1 $z 0
990    __
$a 20110303103805 $b ABA008
991    __
$a 20151006142239 $b ABA008
999    __
$a ok $b bmc $g 831757 $s 696433
BAS    __
$a 3
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S71-S80 $m Physiological research $x MED00003824
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S71-S80 $m Methods in experimental and clinical cardiovascular research $x MED00178497
LZP    __
$a 2011-14/ipme

Citační ukazatele

Nahrávání dat...