Introduction to post-processing techniques
F Jiru
Jazyk angličtina Země Irsko
Typ dokumentu práce podpořená grantem, přehledy
NLK
ScienceDirect (archiv)
od 1993-01-01 do 2009-12-31
- MeSH
- algoritmy MeSH
- artefakty MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie metody MeSH
- počítačové zpracování obrazu metody MeSH
- počítačové zpracování signálu MeSH
- tělesná voda metabolismus MeSH
- vylepšení obrazu metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- přehledy MeSH
The quality of data measured in in vivo MR spectroscopy is often insufficient due to a number of limitations such as low concentrations of observed metabolites and restricted measurement time resulting in a low signal-to-noise ratio. However, there are a variety of methods called post-processing techniques which allow the enhancement of the measured signal after measurement. In this review an introduction to the most important post-processing techniques for (1)H MR spectroscopy is given and practical examples are shown. In the first section the concept of FID and spectrum is introduced and the relationship between FID and spectrum is explained. Subsequently, the objectives and description of the following post-processing techniques are provided: eddy current correction, removal of an unwanted component (water), signal filtering for various purposes, zero filling, phase correction and baseline correction.
- 000
- 02141naa 2200301 a 4500
- 001
- bmc11006410
- 003
- CZ-PrNML
- 005
- 20120906141224.0
- 008
- 110401s2008 ie e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Jírů, Filip, $d 1976- $7 xx0074154
- 245 10
- $a Introduction to post-processing techniques / $c F Jiru
- 314 __
- $a MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic. fiji@medicon.cz <fiji@medicon.cz>
- 520 9_
- $a The quality of data measured in in vivo MR spectroscopy is often insufficient due to a number of limitations such as low concentrations of observed metabolites and restricted measurement time resulting in a low signal-to-noise ratio. However, there are a variety of methods called post-processing techniques which allow the enhancement of the measured signal after measurement. In this review an introduction to the most important post-processing techniques for (1)H MR spectroscopy is given and practical examples are shown. In the first section the concept of FID and spectrum is introduced and the relationship between FID and spectrum is explained. Subsequently, the objectives and description of the following post-processing techniques are provided: eddy current correction, removal of an unwanted component (water), signal filtering for various purposes, zero filling, phase correction and baseline correction.
- 590 __
- $a bohemika - dle Pubmed
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a artefakty $7 D016477
- 650 _2
- $a tělesná voda $x metabolismus $7 D001834
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a vylepšení obrazu $x metody $7 D007089
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 _2
- $a magnetická rezonanční spektroskopie $x metody $7 D009682
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 773 0_
- $t European Journal of Radiology $w MED00009640 $g Roč. 67, č. 2 (2008), s. 202-217 $x 0720-048X
- 910 __
- $a ABA008 $b B 1595 $y 2
- 990 __
- $a 20110414104233 $b ABA008
- 991 __
- $a 20120906141355 $b ABA008
- 999 __
- $a ok $b bmc $g 834002 $s 698511
- BAS __
- $a 3
- BMC __
- $a 2008 $b 67 $c 2 $d 202-217 $i 0720-048X $m European journal of radiology $n Eur J Radiol $x MED00009640
- LZP __
- $a 2011-1B09/jjme