Comparison of UV and charged aerosol detection approach in pharmaceutical analysis of statins

L. Nováková, S.A. Lopéz, D. Solichová, D. Šatínský, B. Kulichová, A. Horna, P. Solich

. 2009 ; 78 (3) : 834-839.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc11009552

Grantová podpora
1A8689 MZ0 CEP - Centrální evidence projektů

CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment-simvastatin, lovastatin and atorvastatin. The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm x 75 mm, 3.5 microm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector-238 nm) simultaneously connected in series. In terms of linearity, precision and accuracy, the method was validated using tablets containing atorvastatin and simvastatin. The CAD is designated to be a non-linear detector in a wide dynamic range, however, in this application and in the tested concentration range its response was found to be perfectly linear. The limits of quantitation (0.1 microg/ml) were found to be two times lower than those of UV detection.

000      
02602naa 2200385 a 4500
001      
bmc11009552
003      
CZ-PrNML
005      
20140226114011.0
008      
110510s2009 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Nováková, Lucie, $d 1979- $7 xx0048951
245    10
$a Comparison of UV and charged aerosol detection approach in pharmaceutical analysis of statins / $c L. Nováková, S.A. Lopéz, D. Solichová, D. Šatínský, B. Kulichová, A. Horna, P. Solich
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic. novakoval@faf.cuni.cz
520    9_
$a CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment-simvastatin, lovastatin and atorvastatin. The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm x 75 mm, 3.5 microm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector-238 nm) simultaneously connected in series. In terms of linearity, precision and accuracy, the method was validated using tablets containing atorvastatin and simvastatin. The CAD is designated to be a non-linear detector in a wide dynamic range, however, in this application and in the tested concentration range its response was found to be perfectly linear. The limits of quantitation (0.1 microg/ml) were found to be two times lower than those of UV detection.
590    __
$a bohemika - dle Pubmed
650    _2
$a aerosoly $7 D000336
650    _2
$a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $7 D002851
650    _2
$a zdravotnické prostředky $7 D004864
650    _2
$a kyseliny heptylové $x analýza $7 D006538
650    _2
$a statiny $x analýza $7 D019161
650    _2
$a lovastatin $x analýza $7 D008148
650    _2
$a pyrroly $x analýza $7 D011758
650    _2
$a simvastatin $x analýza $7 D019821
650    _2
$a tablety $7 D013607
650    _2
$a financování organizované $7 D005381
700    1_
$a Lopéz, Sofía Arnal
700    1_
$a Solichová, Dagmar $7 xx0060526
700    1_
$a Šatínský, Dalibor $7 xx0019028
700    1_
$a Kulichová, Bohumila $7 xx0119832
700    1_
$a Horna, Aleš. $7 mzk2008434281
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395
773    0_
$t Talanta $w MED00004484 $g Roč. 78, č. 3 (2009), s. 834-839
910    __
$a ABA008 $b x $y 2 $z 0
990    __
$a 20110513110101 $b ABA008
991    __
$a 20140226114823 $b ABA008
999    __
$a ok $b bmc $g 839085 $s 702940
BAS    __
$a 3
BMC    __
$a 2009 $b 78 $c 3 $d 834-839 $m Talanta $n Talanta $x MED00004484
GRA    __
$a 1A8689 $p MZ0
LZP    __
$a 2011-2B09/jvme

Najít záznam