Metoda MORF pro sledování velikostí a tvarů otěrových mikro- a nanočástic UHMWPE v periprotetických tkáních
[MORF method for assessment of the size and shape of UHMWPE wear microparticles and nanoparticles in periprosthetic tissues]

Fulín P, Pokorný D, Slouf M, Lapčíková M, Pavlova E, Zolotarevová E.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc11010779

Grantová podpora
NT12229 MZ0 CEP - Centrální evidence projektů

PURPOSE OF STUDY Aseptic loosening of total joint replacement (TJR) due to wear of ultra-high molecular weight polyethylene (UHMWPE) is regarded as one of the major problems in the field of arthroplasty. This work describes a newly developed method, cal- led MORF, which completely describes the morphology of UHMWPE wear particles. The differences in wear particle mor - phology may help to elucidate individual differences in TJR failures. MATERIAL AND METHODS During the years 2002-2010, a set of 47 typical damaged periprosthetic tissues, coming from 16 TJR revisions, was col- lected. Isolated on polycarbonate (PC) filters were quantified. Quantification of the particles consisted in determination of their concentration and description of their morphology by means of the newly developed MORF method. Firstly, the mic- rographs of isolated UHMWPE particles were obtained with a scanning electron microscope (Quanta 200 FEG; FEI) at two magnifications: x1200 and x6000. Secondly, both high- and low-magnification micrographs were processed by a standard image analysis software (program NIS Elements; Laboratory Imaging) in order to obtain basic morphological descriptors. Finally, the results from image analysis of high- and low- magnification micrographs were combined by means of our own program MDISTR in order to obtain correct particle sizes and shapes. RESULTS In the first stage, the method was applied to 25 samples and yielded an average particle size of 0.51 µm. In the second stage, the method was further improved in order to calculate not only the size of particles but also the shape of descrip- tors. The improved method was applied to eight samples and gave an average size of particles (equivalent diameter, D) in the range of 0.27 - 0.60 µm, circularity (C) of 0.66-0.85 and elongation (E) of 1.75-1.79, suggesting that the great majori- ty of particles were approximately spherical. Finally, in the third stage, the MORF method was applied to two exceptional samples which contained extremely small wear particles (D = 18.5 nm and 21.2 nm). The shape of these small wear nano- particles (C = 0.97 and 0.93; E = 1.29 and 1.35) was even more spherical than that of wear microparticles described abo- ve. This was one of the first two studies which proved the presence of UHMWPE wear nanoparticles in vivo. DISCUSSION Our newly developed MORF method described in this contribution yields both size and shape descriptors of UHMWPE wear particles, with sizes from 0.1 to 10 µm, which are regarded as most biologically active. The main objective of the met- hod is to yield the highest accuracy. This is achieved by parallel analyses of high- and low-magnification micrographs taken of the same sample. In the end, the two analyses are combined together in order to obtain the correct and complete size and shape description of all particles in the sample. The morphology of UHMWPE wear particles influences TJR lifetime both directly (size and shape of the particles is related to their biological activity) and indirectly (for the given total volu- metric wear, size and shape of the particles influence their concentration, which is associated with the biological respon- se of the organism). CONCLUSION The authors have developed a new method which yields a complete description of the size and shape of UHMWPE wear particles in periprosthetic tissues. The method, which was called MORF, can be applied to studies of TJR failures and also used to evaluate the quality of different UHMWPE components of TJR. The method is quite universal and therefore can be used not only for analyses of wear particles, but also for other types of particles, such as microparticles in polymer blends or inorganic/metallic nanoparticles. Key words: UHMWPE, wear debris, total joint replacement, morphology of wear particles.

MORF method for assessment of the size and shape of UHMWPE wear microparticles and nanoparticles in periprosthetic tissues

Citace poskytuje Crossref.org

Bibliografie atd.

Lit.: 33

000      
00000naa 2200000 a 4500
001      
bmc11010779
003      
CZ-PrNML
005      
20170427101657.0
008      
110518s2011 xr e cze||
009      
AR
024    7_
$a 10.55095/achot2011/021 $2 doi
035    __
$a (PubMed)21575556
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Fulín, Petr. $7 xx0231618
245    10
$a Metoda MORF pro sledování velikostí a tvarů otěrových mikro- a nanočástic UHMWPE v periprotetických tkáních / $c Fulín P, Pokorný D, Slouf M, Lapčíková M, Pavlova E, Zolotarevová E.
246    11
$a MORF method for assessment of the size and shape of UHMWPE wear microparticles and nanoparticles in periprosthetic tissues
314    __
$a I. ortopedická klinika 1. LF UK a FN Motol, Praha
504    __
$a Lit.: 33
520    9_
$a PURPOSE OF STUDY Aseptic loosening of total joint replacement (TJR) due to wear of ultra-high molecular weight polyethylene (UHMWPE) is regarded as one of the major problems in the field of arthroplasty. This work describes a newly developed method, cal- led MORF, which completely describes the morphology of UHMWPE wear particles. The differences in wear particle mor - phology may help to elucidate individual differences in TJR failures. MATERIAL AND METHODS During the years 2002-2010, a set of 47 typical damaged periprosthetic tissues, coming from 16 TJR revisions, was col- lected. Isolated on polycarbonate (PC) filters were quantified. Quantification of the particles consisted in determination of their concentration and description of their morphology by means of the newly developed MORF method. Firstly, the mic- rographs of isolated UHMWPE particles were obtained with a scanning electron microscope (Quanta 200 FEG; FEI) at two magnifications: x1200 and x6000. Secondly, both high- and low-magnification micrographs were processed by a standard image analysis software (program NIS Elements; Laboratory Imaging) in order to obtain basic morphological descriptors. Finally, the results from image analysis of high- and low- magnification micrographs were combined by means of our own program MDISTR in order to obtain correct particle sizes and shapes. RESULTS In the first stage, the method was applied to 25 samples and yielded an average particle size of 0.51 µm. In the second stage, the method was further improved in order to calculate not only the size of particles but also the shape of descrip- tors. The improved method was applied to eight samples and gave an average size of particles (equivalent diameter, D) in the range of 0.27 - 0.60 µm, circularity (C) of 0.66-0.85 and elongation (E) of 1.75-1.79, suggesting that the great majori- ty of particles were approximately spherical. Finally, in the third stage, the MORF method was applied to two exceptional samples which contained extremely small wear particles (D = 18.5 nm and 21.2 nm). The shape of these small wear nano- particles (C = 0.97 and 0.93; E = 1.29 and 1.35) was even more spherical than that of wear microparticles described abo- ve. This was one of the first two studies which proved the presence of UHMWPE wear nanoparticles in vivo. DISCUSSION Our newly developed MORF method described in this contribution yields both size and shape descriptors of UHMWPE wear particles, with sizes from 0.1 to 10 µm, which are regarded as most biologically active. The main objective of the met- hod is to yield the highest accuracy. This is achieved by parallel analyses of high- and low-magnification micrographs taken of the same sample. In the end, the two analyses are combined together in order to obtain the correct and complete size and shape description of all particles in the sample. The morphology of UHMWPE wear particles influences TJR lifetime both directly (size and shape of the particles is related to their biological activity) and indirectly (for the given total volu- metric wear, size and shape of the particles influence their concentration, which is associated with the biological respon- se of the organism). CONCLUSION The authors have developed a new method which yields a complete description of the size and shape of UHMWPE wear particles in periprosthetic tissues. The method, which was called MORF, can be applied to studies of TJR failures and also used to evaluate the quality of different UHMWPE components of TJR. The method is quite universal and therefore can be used not only for analyses of wear particles, but also for other types of particles, such as microparticles in polymer blends or inorganic/metallic nanoparticles. Key words: UHMWPE, wear debris, total joint replacement, morphology of wear particles.
650    _2
$a financování organizované $7 D005381
650    _2
$a náhrada kyčelního kloubu $7 D019644
650    _2
$a analýza selhání vybavení $7 D019544
650    _2
$a kyčelní kloub $x patologie $7 D006621
650    _2
$a kyčelní protézy $7 D006622
650    _2
$a lidé $7 D006801
650    _2
$a počítačové zpracování obrazu $7 D007091
650    _2
$a mikroskopie elektronová rastrovací $7 D008855
650    _2
$a nanočástice $7 D053758
650    _2
$a velikost částic $7 D010316
650    _2
$a polyethyleny $7 D011095
700    1_
$a Pokorný, David, $d 1968- $7 jn20001103568
700    1_
$a Šlouf, Miroslav, $d 1973- $7 xx0107048
700    1_
$a Lapčíková, M. $7 _AN060240
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca $g Roč. 78, č. 2 (2011), s. 131-137 $x 0001-5415
910    __
$a ABA008 $b A 8 $c 507 $y 7 $z 0
990    __
$a 20110518092319 $b ABA008
991    __
$a 20170427102017 $b ABA008
999    __
$a ok $b bmc $g 840192 $s 704227
BAS    __
$a 3
BMC    __
$a 2011 $b 78 $c 2 $d 131-137 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x MED00011021
GRA    __
$a NT12229 $p MZ0
LZP    __
$a 2011-08/mkme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé