Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Comparison of Doppler flow Tei-indexes with pulmonary artery thermodilution measurement of cardiac output in an experimental porcine model

J. Kobr, V. Třeška, J. Moláček, V. Kuntscher, V. Liška, Z. Slavík

. 2011 ; 60 (3) : 483-492.

Jazyk angličtina Země Česko

Typ dokumentu srovnávací studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc11032057

The objective of our study was to compare Doppler echocardiography imaging with pulmonary artery thermodilution measurement during mechanical ventilation. Total 78 piglets (6 weeks old, average weight 24 kg, under general anesthesia) were divided into 4 groups under different cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload, and with increased afterload of both heart ventricles). At 60 and 120 min the animals were examined by echocardiography and simultaneously pulmonary artery thermodilution was used to measure cardiac output. Tei-indexes data were compared with invasively monitored hemodynamic data and cardiac output values together with calculated vascular resistance indices. A total of 224 parallel measurements were obtained. Correlation was found between values of right Tei-index of myocardial performance and changes in right ventricular preload (p<0.05) and afterload (p<0.01). Significant correlation was also found between left index values and changes of left ventricular preload (p<0.001), afterload (p<0.001), stroke volume (p<0.01), and cardiac output (p<0.01). In conclusion, echocardiographic examination and determination of the global performance selectively for the right and left ventricle can be recommended as a suitable non-invasive supplement to the whole set of methods used for monitoring of circulation and cardiac performance.

Citace poskytuje Crossref.org

Bibliografie atd.

Lit.: 36

000      
00000naa 2200000 a 4500
001      
bmc11032057
003      
CZ-PrNML
005      
20130131150020.0
008      
110912s2011 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.932015 $2 doi
035    __
$a (PubMed)21401299
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Kobr, Jiří, $d 1950- $7 xx0102261
245    10
$a Comparison of Doppler flow Tei-indexes with pulmonary artery thermodilution measurement of cardiac output in an experimental porcine model / $c J. Kobr, V. Třeška, J. Moláček, V. Kuntscher, V. Liška, Z. Slavík
314    __
$a Charles University in Prague, Faculty of Medicine in Pilsen, Pilsen, Czech Republic. kobr@fnplzen.cz.
504    __
$a Lit.: 36
520    9_
$a The objective of our study was to compare Doppler echocardiography imaging with pulmonary artery thermodilution measurement during mechanical ventilation. Total 78 piglets (6 weeks old, average weight 24 kg, under general anesthesia) were divided into 4 groups under different cardiac loading conditions (at rest, with increased left ventricular afterload, with increased right ventricular preload, and with increased afterload of both heart ventricles). At 60 and 120 min the animals were examined by echocardiography and simultaneously pulmonary artery thermodilution was used to measure cardiac output. Tei-indexes data were compared with invasively monitored hemodynamic data and cardiac output values together with calculated vascular resistance indices. A total of 224 parallel measurements were obtained. Correlation was found between values of right Tei-index of myocardial performance and changes in right ventricular preload (p<0.05) and afterload (p<0.01). Significant correlation was also found between left index values and changes of left ventricular preload (p<0.001), afterload (p<0.001), stroke volume (p<0.01), and cardiac output (p<0.01). In conclusion, echocardiographic examination and determination of the global performance selectively for the right and left ventricle can be recommended as a suitable non-invasive supplement to the whole set of methods used for monitoring of circulation and cardiac performance.
650    02
$a zvířata $7 D000818
650    02
$a minutový srdeční výdej $x fyziologie $7 D002302
650    02
$a dopplerovská echokardiografie $x metody $7 D015150
650    02
$a ženské pohlaví $7 D005260
650    02
$a funkční vyšetření srdce $7 D006334
650    02
$a mužské pohlaví $7 D008297
650    02
$a modely u zvířat $7 D023421
650    02
$a arteria pulmonalis $x fyziologie $7 D011651
650    02
$a prasata $7 D013552
650    02
$a termodiluce $7 D013815
650    02
$a cévní rezistence $x fyziologie $7 D014655
650    02
$a funkce levé komory srdeční $x fyziologie $7 D016277
650    02
$a funkce pravé komory srdeční $x fyziologie $7 D016278
655    _2
$a srovnávací studie $7 D003160
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Třeška, Vladislav, $d 1957- $7 jn20000402436
700    1_
$a Moláček, Jiří, $d 1975- $7 xx0061007
700    1_
$a Kuntscher, Vilém, $d 1966- $7 xx0081969
700    1_
$a Liška, Václav, $d 1978- $7 xx0073943
700    1_
$a Slavík, Zdeněk $7 xx0156392
773    0_
$w MED00003824 $t Physiological research $g Roč. 60, č. 3 (2011), s. 483-492 $x 0862-8408
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/60/60_483.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 2
990    __
$a 20110912095705 $b ABA008
991    __
$a 20130131150147 $b ABA008
999    __
$a ok $b bmc $g 877137 $s 742134
BAS    __
$a 3
BMC    __
$a 2011 $b 60 $c 3 $d 483-492 $m Physiological research $x MED00003824
LZP    __
$a 2011-16/mkme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé