Koncentrace aerosolových částic v zubní ordinaci [Aerosol particle concentration in dental surgery]
Jiří Smolík, Lucie Ondráčková, Jiřina Maršíková
Jazyk čeština Země Česko
- MeSH
- aerosoly škodlivé účinky MeSH
- ordinace MeSH
- vystavení vlivu životního prostředí MeSH
- zubní lékařství MeSH
Verification of a simple technique for monitoring of aerosol particles in dental surgery as well as determination of particle concentrations and size distribution were performed. It was found that the main source of aerosol particles in the surgery hours is teeth drilling, grinding and resuspension of particles in cleaning the surgery. The particle concentration increased 1.5 times during the surgery and the total particle concentrations during surgery hours were by 30 % higher compared with the background values. The concentration increase was pronounced in all particle size fractions, the largest for particles < 1µm. Comparing the results of mass and number concentrations of submicron fraction, it was found out that the individual surgery is capable of producing particles < 0.375 µm.
Aerosol particle concentration in dental surgery
Lit.: 34
- 000
- 00000naa 2200000 a 4500
- 001
- bmc11033018
- 003
- CZ-PrNML
- 005
- 20111210221552.0
- 008
- 110915s2011 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze
- 044 __
- $a xr
- 100 1_
- $a Smolík, Jiří $7 xx0128924
- 245 10
- $a Koncentrace aerosolových částic v zubní ordinaci / $c Jiří Smolík, Lucie Ondráčková, Jiřina Maršíková
- 246 11
- $a Aerosol particle concentration in dental surgery
- 314 __
- $a Laboratoř chemie a fyziky aerosolů, Ústav chemických procesů AV ČR v.v.i., Praha 6
- 504 __
- $a Lit.: 34
- 520 9_
- $a Verification of a simple technique for monitoring of aerosol particles in dental surgery as well as determination of particle concentrations and size distribution were performed. It was found that the main source of aerosol particles in the surgery hours is teeth drilling, grinding and resuspension of particles in cleaning the surgery. The particle concentration increased 1.5 times during the surgery and the total particle concentrations during surgery hours were by 30 % higher compared with the background values. The concentration increase was pronounced in all particle size fractions, the largest for particles < 1µm. Comparing the results of mass and number concentrations of submicron fraction, it was found out that the individual surgery is capable of producing particles < 0.375 µm.
- 650 _2
- $a vystavení vlivu životního prostředí $7 D004781
- 650 _2
- $a aerosoly $x škodlivé účinky $7 D000336
- 650 _2
- $a ordinace $7 D010824
- 650 _2
- $a zubní lékařství $7 D003813
- 700 1_
- $a Ondráčková, Lucie. $7 _AN042203
- 700 1_
- $a Maršíková, Jiřina. $7 _AN062941
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 105, č. 5 (2011), s. 371-374 $x 0009-2770
- 856 41
- $u http://www.chemicke-listy.cz/docs/full/2011_05_371-374.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 1
- 990 __
- $a 20110908070058 $b ABA008
- 991 __
- $a 20110915142456 $b ABA008
- 999 __
- $a ok $b bmc $g 878118 $s 743097
- BAS __
- $a 3
- BMC __
- $a 2011 $b 105 $c 5 $d 371-374 $m Chemické listy $x MED00011010
- LZP __
- $a 2011-45/vtjs