Je něco špatně v tomto záznamu ?
Interlaboratory comparative tests of biological laboratories of the nato armies
Libor Pisa , Radoslav Krupka, Veronika Formankova, Vera Neubauerova, Jiri Dresler, Martin Hubalek
Jazyk angličtina Země Česko
Digitální knihovna NLK
Zdroj
NLK
ROAD: Directory of Open Access Scholarly Resources
od 2011
- MeSH
- Bacillus anthracis genetika izolace a purifikace MeSH
- bakteriologické techniky metody přístrojové vybavení využití MeSH
- biologické bojové látky MeSH
- DNA bakterií analýza genetika MeSH
- financování organizované MeSH
- hodnotící studie jako téma MeSH
- laboratoře MeSH
- lidé MeSH
- nebezpečné látky izolace a purifikace MeSH
- polymerázová řetězová reakce metody přístrojové vybavení využití MeSH
- senzitivita a specificita MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vojenská věda MeSH
- Check Tag
- lidé MeSH
One of the key requirements of the biodefense system of the Czech Armed Forces is a capability to identify the biological warfare agents (BWA). In this regard the Central Military Health Institute that is responsible for the biodefense in the Czech Armed Forces took part in 10thAnnual international comparative exercise of the NATO (North Atlantic Treaty Organization) military biological laboratories. The aim of this test was the identification of Bacillus anthracis in unknown samples which were contaminated by different disinfectants. Real-time polymerase chain reaction (PCR) was chosen as optimal method for this exercise because of a robustness, speed and flexibility of this method. Due to the presence of a disinfectant the identification procedure could only be conducted after including an additional step to sample preparation. Tandem mass spectrometry was selected as a confirmatory method for the exercise. Our test result was in full agreement with the exercise design. This exercise confirmed that method of provisional identification deployable in mobile component of biodefense system of the Czech Armed Forces is sensitive and robust for use in the field conditions. The tandem mass spectrometry analysis confirmed PCR results and verified the valuable confirmatory role of mass spectrometry in the identification of biological agents.
Citace poskytuje Crossref.org
Obsahuje 4 tabulky
Bibliografie atd.Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12003998
- 003
- CZ-PrNML
- 005
- 20120316140705.0
- 007
- ta
- 008
- 120208s2011 xr ofd f 000 0eng||
- 009
- AR
- 024 7_
- $a 10.31482/mmsl.2011.022 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Píša, Libor. $7 _AN065762 $u Central Military Health Institute, Prague; Institute of Molecular Pathology, Faculty of Military Health Sciences, University of Defense, Hradec Králové
- 245 10
- $a Interlaboratory comparative tests of biological laboratories of the nato armies / $c Libor Pisa , Radoslav Krupka, Veronika Formankova, Vera Neubauerova, Jiri Dresler, Martin Hubalek
- 500 __
- $a Obsahuje 4 tabulky
- 504 __
- $a Literatura $b 34
- 520 9_
- $a One of the key requirements of the biodefense system of the Czech Armed Forces is a capability to identify the biological warfare agents (BWA). In this regard the Central Military Health Institute that is responsible for the biodefense in the Czech Armed Forces took part in 10thAnnual international comparative exercise of the NATO (North Atlantic Treaty Organization) military biological laboratories. The aim of this test was the identification of Bacillus anthracis in unknown samples which were contaminated by different disinfectants. Real-time polymerase chain reaction (PCR) was chosen as optimal method for this exercise because of a robustness, speed and flexibility of this method. Due to the presence of a disinfectant the identification procedure could only be conducted after including an additional step to sample preparation. Tandem mass spectrometry was selected as a confirmatory method for the exercise. Our test result was in full agreement with the exercise design. This exercise confirmed that method of provisional identification deployable in mobile component of biodefense system of the Czech Armed Forces is sensitive and robust for use in the field conditions. The tandem mass spectrometry analysis confirmed PCR results and verified the valuable confirmatory role of mass spectrometry in the identification of biological agents.
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a hodnotící studie jako téma $7 D005069
- 650 _2
- $a Bacillus anthracis $x genetika $x izolace a purifikace $7 D001408
- 650 _2
- $a biologické bojové látky $7 D054045
- 650 _2
- $a vojenská věda $7 D008891
- 650 _2
- $a laboratoře $7 D007753
- 650 _2
- $a bakteriologické techniky $x metody $x přístrojové vybavení $x využití $7 D001431
- 650 _2
- $a polymerázová řetězová reakce $x metody $x přístrojové vybavení $x využití $7 D016133
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 650 _2
- $a DNA bakterií $x analýza $x genetika $7 D004269
- 650 _2
- $a nebezpečné látky $x izolace a purifikace $7 D015386
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a lidé $7 D006801
- 700 1_
- $a Krupka, Radoslav $7 xx0104291 $u Central Military Health Institute, Prague
- 700 1_
- $a Formánková, Veronika. $7 _AN065763 $u Central Military Health Institute, Prague
- 700 1_
- $a Neubauerová, Věra, $d 1973- $7 stk2007383205 $u Central Military Health Institute, Prague
- 700 1_
- $a Dresler, Jiří. $7 xx0262844 $u Central Military Health Institute, Prague; Institute of Molecular Pathology, Faculty of Military Health Sciences, University of Defense, Hradec Králové
- 700 1_
- $a Hubálek, Martin, $d 1976- $7 xx0142582 $u Institute of Molecular Pathology, Faculty of Military Health Sciences, University of Defense, Hradec Králové
- 773 0_
- $t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 80, č. 4 (2011), s. 159-168 $w MED00011116
- 910 __
- $a ABA008 $b A 3 $c 1073 $y 2
- 990 __
- $a 20120208133757 $b ABA008
- 991 __
- $a 20120316140637 $b ABA008
- 999 __
- $a ok $b bmc $g 896897 $s 760777
- BAS __
- $a 3
- BMC __
- $a 2011 $b 80 $c 4 $d 159-168 $i 0372-7025 $m Vojenské zdravotnické listy $n Vojen. zdr. listy $x MED00011116
- LZP __
- $a 2012-07/dkhv