• Je něco špatně v tomto záznamu ?

Time-dependent changes in concentration of two clinically used acetylcholinesterase reactivators (HI-6 and obidoxime) in rat plasma determined by HPLC techniques after in vivo administration

Karasova J Zdarova, L Novotny, K Antos, H Zivna, K Kuca

. 2010 ; 26 (1) : 63-67.

Jazyk angličtina Země Japonsko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12008378

A simple and reliable HPLC method for determination of rat plasma levels of clinically used acetylcholinesterase (AChE) reactivators (HI-6 and obidoxime) is presented in our study. Separation was carried out by HPLC using an octadecyl silica stationary phase and a mobile phase consisting of 24% acetonitrile and containing 5 mM sodium octanesulfonate and 5 mM tetramethylammonium chloride (pH 2.3). Following intramuscular administration of equimolar doses of both oximes (22.23 mg/kg), the maximum of HI-6 concentration in rat plasma was reached in about 20 min giving 15.26 +/- 1.71 microg/mL. The distribution of obidoxime was fast; the single maximum 23.62 +/- 3.563 microg/mL was recorded at about 10 min. HPLC with UV detection presented in our study is a general method which could be applied for quick measurements of bisquaternary AChE reactivators in rat plasma.

000      
02827naa a2200493 a 4500
001      
bmc12008378
003      
CZ-PrNML
005      
20120817145652.0
008      
120315s2010 ja eng||
009      
AR
040    __
$a ABA008 $b cze $d ABA008
041    0_
$a eng
044    __
$a ja
100    1_
$a Žďárová Karasová, Jana, $d 1982- $7 xx0099787 $u Department of Toxicology, Faculty of Health Sciences, University of Defence, Trebesska 1575, 500 01 Hradec Kralove, Czech Republic. karasova@pmfhk.cz
245    10
$a Time-dependent changes in concentration of two clinically used acetylcholinesterase reactivators (HI-6 and obidoxime) in rat plasma determined by HPLC techniques after in vivo administration / $c Karasova J Zdarova, L Novotny, K Antos, H Zivna, K Kuca
520    9_
$a A simple and reliable HPLC method for determination of rat plasma levels of clinically used acetylcholinesterase (AChE) reactivators (HI-6 and obidoxime) is presented in our study. Separation was carried out by HPLC using an octadecyl silica stationary phase and a mobile phase consisting of 24% acetonitrile and containing 5 mM sodium octanesulfonate and 5 mM tetramethylammonium chloride (pH 2.3). Following intramuscular administration of equimolar doses of both oximes (22.23 mg/kg), the maximum of HI-6 concentration in rat plasma was reached in about 20 min giving 15.26 +/- 1.71 microg/mL. The distribution of obidoxime was fast; the single maximum 23.62 +/- 3.563 microg/mL was recorded at about 10 min. HPLC with UV detection presented in our study is a general method which could be applied for quick measurements of bisquaternary AChE reactivators in rat plasma.
590    __
$a bohemika - dle Pubmed
650    02
$a zvířata $7 D000818
650    02
$a krevní proteiny $x chemie $7 D001798
650    02
$a kalibrace $7 D002138
650    02
$a reaktivátory cholinesterázy $x farmakokinetika $x krev $7 D002801
650    02
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    02
$a indikátory a reagencie $7 D007202
650    02
$a injekce intramuskulární $7 D007273
650    02
$a mužské pohlaví $7 D008297
650    02
$a obidoxim chlorid $x farmakokinetika $x krev $7 D009768
650    02
$a oximy $x farmakokinetika $x krev $7 D010091
650    02
$a pyridinové sloučeniny $x farmakokinetika $x krev $7 D011726
650    02
$a krysa rodu Rattus $7 D051381
650    02
$a potkani Wistar $7 D017208
650    02
$a reprodukovatelnost výsledků $7 D015203
650    02
$a spektrofotometrie ultrafialová $7 D013056
650    02
$a kyselina trichloroctová $x chemie $7 D014238
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Novotný, Ladislav. $7 _AN063631
700    1_
$a Antoš, Karel, $d 1966- $7 xx0070231
700    1_
$a Živná, Helena $7 xx0093373
700    1_
$a Kuča, Kamil, $d 1978- $7 xx0041831
773    0_
$t Analytical Sciences $p Anal Sci $g Roč. 26, č. 1 (2010), s. 63-67 $w MED00004930 $x 0910-6340
910    __
$a ABA008 $b x $y 4
990    __
$a 20120319124412 $b ABA008
991    __
$a 20120817145743 $b ABA008
999    __
$a ok $b bmc $g 901837 $s 765269
BAS    __
$a 3
BMC    __
$a 2010 $b 26 $c 1 $d 63-67 $m Analytical sciences $x MED00004930 $i 0910-6340
LZP    __
$a 2012-1Q10/jt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...