Je něco špatně v tomto záznamu ?
Determination of pravastatin and pravastatin lactone in rat plasma and urine using UHPLC-MS/MS and microextraction by packed sorbent
H. Vlčková, M. Rabatinová, A. Mikšová, G. Kolouchová, S. Mičuda, P. Solich, L. Nováková,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- krysa rodu rattus MeSH
- laktony krev moč MeSH
- mikroextrakce na pevné fázi metody MeSH
- pravastatin krev moč MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A simple and reproducible method for the determination of pravastatin and pravastatin lactone in rat plasma and urine by means of ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) using deuterium labeled internal standards for quantification is reported. Separation of analytes was performed on BEH C(18) analytical column (50 mm × 2.1mm, 1.7 μm), using gradient elution by mobile phase consisting of acetonitrile and 1mM ammonium acetate at pH 4.0. Run time was 2 min. Quantification of analytes was performed using the SRM (selected reaction monitoring) experiment in ESI negative ion mode for pravastatin and in ESI positive ion mode for pravastatin lactone. Sample treatment consisted of a protein precipitation by ACN and microextraction by packed sorbent (MEPS) for rat plasma. Simple MEPS procedure was sufficient for rat urine. MEPS was implemented using the C8 sorbent inserted into a microvolume syringe, eVol hand-held automated analytical syringe and a small volume of sample (50 μl). The analytes were eluted by 100 μl of the mixture of acetonitrile: 0.01 M ammonium acetate pH 4.5 (90:10, v:v). The method was validated and demonstrated good linearity in range 5-500 nmol/l (r(2)>0.9990) for plasma and urine samples. Method recovery was ranged within 97-109% for plasma samples and 92-101% for the urine samples. Intra-day precision expressed as the % of RSD was lower than 8% for the plasma samples and lower than 7% for the urine samples. The method was validated with sensitivity reaching LOD 1.5 nmol/l and LOQ 5 nmol/l in plasma and urine samples. The method was applied for the measurement of pharmacokinetic plots of pravastatin and pravastatin lactone in rat plasma and urine samples.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12024023
- 003
- CZ-PrNML
- 005
- 20121210105911.0
- 007
- ta
- 008
- 120815e20120109enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2011.12.043 $2 doi
- 035 __
- $a (PubMed)22340111
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Vlčková, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 245 10
- $a Determination of pravastatin and pravastatin lactone in rat plasma and urine using UHPLC-MS/MS and microextraction by packed sorbent / $c H. Vlčková, M. Rabatinová, A. Mikšová, G. Kolouchová, S. Mičuda, P. Solich, L. Nováková,
- 520 9_
- $a A simple and reproducible method for the determination of pravastatin and pravastatin lactone in rat plasma and urine by means of ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) using deuterium labeled internal standards for quantification is reported. Separation of analytes was performed on BEH C(18) analytical column (50 mm × 2.1mm, 1.7 μm), using gradient elution by mobile phase consisting of acetonitrile and 1mM ammonium acetate at pH 4.0. Run time was 2 min. Quantification of analytes was performed using the SRM (selected reaction monitoring) experiment in ESI negative ion mode for pravastatin and in ESI positive ion mode for pravastatin lactone. Sample treatment consisted of a protein precipitation by ACN and microextraction by packed sorbent (MEPS) for rat plasma. Simple MEPS procedure was sufficient for rat urine. MEPS was implemented using the C8 sorbent inserted into a microvolume syringe, eVol hand-held automated analytical syringe and a small volume of sample (50 μl). The analytes were eluted by 100 μl of the mixture of acetonitrile: 0.01 M ammonium acetate pH 4.5 (90:10, v:v). The method was validated and demonstrated good linearity in range 5-500 nmol/l (r(2)>0.9990) for plasma and urine samples. Method recovery was ranged within 97-109% for plasma samples and 92-101% for the urine samples. Intra-day precision expressed as the % of RSD was lower than 8% for the plasma samples and lower than 7% for the urine samples. The method was validated with sensitivity reaching LOD 1.5 nmol/l and LOQ 5 nmol/l in plasma and urine samples. The method was applied for the measurement of pharmacokinetic plots of pravastatin and pravastatin lactone in rat plasma and urine samples.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a laktony $x krev $x moč $7 D007783
- 650 _2
- $a pravastatin $x krev $x moč $7 D017035
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a mikroextrakce na pevné fázi $x metody $7 D052617
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Rabatinová, Martina
- 700 1_
- $a Mikšová, Alena
- 700 1_
- $a Kolouchová, Gabriela
- 700 1_
- $a Mičuda, Stanislav
- 700 1_
- $a Solich, Petr
- 700 1_
- $a Nováková, Lucie
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 90(20120109), s. 22-9
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22340111 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120815 $b ABA008
- 991 __
- $a 20121210105947 $b ABA008
- 999 __
- $a ok $b bmc $g 946171 $s 781351
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 90 $d 22-9 $e 20120109 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20120815/12/02