• Je něco špatně v tomto záznamu ?

Air Kerma Rate estimation by means of in-situ gamma spectrometry: a Bayesian approach

G. Cabal, J. Kluson

. 2009 ; 68 (4-5) : 804-806. [pub] 20090925

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12025467

Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025467
003      
CZ-PrNML
005      
20130301191210.0
007      
ta
008      
120816e20090925enk f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.apradiso.2009.09.062 $2 doi
035    __
$a (PubMed)19914079
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Cabal, Gonzalo $u Department of Dosimetry and Applications of Ionizing Radiation, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague, Czech Republic. cabal@ujf.cas.cz
245    10
$a Air Kerma Rate estimation by means of in-situ gamma spectrometry: a Bayesian approach / $c G. Cabal, J. Kluson
520    9_
$a Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%.
650    _2
$a vzduch $7 D000388
650    _2
$a algoritmy $7 D000465
650    _2
$a Bayesova věta $7 D001499
650    _2
$a rozpoznávání automatizované $x metody $7 D010363
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a spektrometrie gama $x metody $7 D013051
655    _2
$a časopisecké články $7 D016428
700    1#
$a Klusoň, Jaroslav, $d 1947- $7 ntka172928
773    0_
$w MED00000499 $t Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine $x 1872-9800 $g Roč. 68, č. 4-5 (20090925), s. 804-806
856    41
$u https://pubmed.ncbi.nlm.nih.gov/19914079 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120816 $b ABA008
991    __
$a 20130301191417 $b ABA008
999    __
$a ok $b bmc $g 947509 $s 782813
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2009 $b 68 $c 4-5 $d 804-806 $e 20090925 $i 1872-9800 $m Applied radiation and isotopes $n Appl Radiat Isot $x MED00000499
LZP    __
$a Pubmed-20120816/10/02

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...