Corrosion behaviour of TiN and ZrN in the environment containing fluoride ions

L. Joska, J. Fojt, M. Hradilova, F. Hnilica, L. Cvrcek,

. 2010 ; 5 (5) : 054108. [pub] 20100928

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026772

Nowadays, a wide range of materials for human implants is used. To reach the required properties of implants, coatings are applied in some cases. This contribution is focused on the corrosion properties of TiN and ZrN layers on cp-titanium (commercially pure titanium) under environment modelling conditions in an oral cavity. Measurements were done in artificial saliva and a physiological solution unbuffered and buffered to a pH value of 4.2 with the addition of fluoride ions up to 4000 ppm. Standard corrosion electrochemical techniques were applied. Both types of layers were stable in both model saliva and physiological solution with non-adjusted pH. The decrease in pH to 4.2 resulted in a minor decrease of corrosion resistance in all cases, but polarization resistance was still in the order of 10(5) Ω cm². An important change in a specimens' behaviour was noticed in the presence of fluoride ions. TiN was stable in the highest concentration of fluorides used. The ZrN layers were destabilized in an environment containing a few hundred ppm of fluoride ions. As for TiN, the decisive factor is the influence of porosity; the corrosion resistance of ZrN is limited. From the corrosion point of view, the application of the TiN-based barrier layers in dental implantology is more advisable than the use of ZrN, provided that the application of a barrier is inevitable.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026772
003      
CZ-PrNML
005      
20160307145003.0
007      
ta
008      
120816s2010 enk f 000 0#eng||
009      
AR
024    7_
$a 10.1088/1748-6041/5/5/054108 $2 doi
035    __
$a (PubMed)20876958
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Joska, Luděk $u Department of Metals and Corrosion Engineering, Institute of Chemical Technology, Technicka 5, 16628 Prague 6, Czech Republic. joskal@vscht.cz $7 xx0103993
245    10
$a Corrosion behaviour of TiN and ZrN in the environment containing fluoride ions / $c L. Joska, J. Fojt, M. Hradilova, F. Hnilica, L. Cvrcek,
520    9_
$a Nowadays, a wide range of materials for human implants is used. To reach the required properties of implants, coatings are applied in some cases. This contribution is focused on the corrosion properties of TiN and ZrN layers on cp-titanium (commercially pure titanium) under environment modelling conditions in an oral cavity. Measurements were done in artificial saliva and a physiological solution unbuffered and buffered to a pH value of 4.2 with the addition of fluoride ions up to 4000 ppm. Standard corrosion electrochemical techniques were applied. Both types of layers were stable in both model saliva and physiological solution with non-adjusted pH. The decrease in pH to 4.2 resulted in a minor decrease of corrosion resistance in all cases, but polarization resistance was still in the order of 10(5) Ω cm². An important change in a specimens' behaviour was noticed in the presence of fluoride ions. TiN was stable in the highest concentration of fluorides used. The ZrN layers were destabilized in an environment containing a few hundred ppm of fluoride ions. As for TiN, the decisive factor is the influence of porosity; the corrosion resistance of ZrN is limited. From the corrosion point of view, the application of the TiN-based barrier layers in dental implantology is more advisable than the use of ZrN, provided that the application of a barrier is inevitable.
650    _2
$a pufry $7 D002021
650    _2
$a koroze $7 D003343
650    _2
$a elektrochemické techniky $7 D055664
650    _2
$a fluoridy $x chemie $7 D005459
650    _2
$a lidé $7 D006801
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a ústa $x chemie $7 D009055
650    _2
$a sliny $x chemie $7 D012463
650    _2
$a náhrada slin $x chemie $7 D012464
650    _2
$a titan $x chemie $7 D014025
650    _2
$a zirkonium $x chemie $7 D015040
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Fojt, Jaroslav $7 _AN077081
700    1_
$a Hradilova, Monika
700    1_
$a Hnilica, František $7 ntka172570
700    1_
$a Cvrček, Ladislav $7 xx0101233
773    0_
$w MED00180190 $t Biomedical materials (Bristol, England) $x 1748-605X $g Roč. 5, č. 5 (2010), s. 054108
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20876958 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120816 $b ABA008
991    __
$a 20160307145017 $b ABA008
999    __
$a ok $b bmc $g 948814 $s 784118
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 5 $c 5 $d 054108 $e 20100928 $i 1748-605X $m Biomedical materials $n Biomed Mater $x MED00180190
LZP    __
$b NLK113 $a Pubmed-20120816/11/01

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...