• Je něco špatně v tomto záznamu ?

Hyphenated technique for the extraction and determination of isoflavones in algae: ultrasound-assisted supercritical fluid extraction followed by fast chromatography with tandem mass spectrometry

B. Klejdus, L. Lojková, M. Plaza, M. Snóblová, D. Stěrbová,

. 2010 ; 1217 (51) : 7956-7965. [pub] 20100716

Jazyk angličtina Země Nizozemsko

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026861

New hyphenated technique for the extraction and determination of isoflavones in sea and freshwater algae and cyanobacteria was developed. The method consists of sonication sample pretreatment, extraction by supercritical CO(2) modified by 3% (v/v) of MeOH/H(2)O mixture (9:1, v/v) at 35 MPa and 40°C for 60 min, fast chromatography analysis by the means of Agilent 1200 Series Rapid Resolution and MS/MS determination. Agilent 1200 Series RRLC was used with Zorbax SB-CN chromatographic column (100 mm × 2.1mm, particle size 3.5 μm), 3μl injection volume, mobile phase consisting of 0.2% (v/v) acetic acid in water (solvent A) and acetonitrile (solvent B) and used with linear gradient (30% B at 0 min, from 0 min to 3 min up to 50% B, from 3 to 6 min up to 80% B and from 6 to 10 min down to 30% B). The flow-rate was 0.4 mL/min, column oven temperature 35°C. MS detector Agilent Technologies 6460 Triple quadrupole LC/MS with Agilent Jet Stream was used in a negative ESI mode under following conditions: gas temperature 350°C, gas flow 13 L/min, nebulizer gas pressure 50 psi, sheath gas temperature 400°C, sheath gas flow 12L/min, capillary voltage was 4 kV. Samples were analysed in the multiple reaction monitoring (MRM) mode. Eight isoflavone compounds were found for the first time in seven real samples of sea algae and in three control samples of freshwater algae and cyanobacteria. Usual optimisation study of extraction parameters was performed. Pressure and temperature optima for algae matrix are different from those obtained sooner for other matrices for most of the analytes, but the results of modifier optimisation study are in good accordance with those obtained sooner for spiked samples and red clover matrix. It seems that matrix has very small or no effect on the modifier selection. Two different approaches of sonication pretreatment were tested: sonication bath and the thorn instrument. In longer extraction time experiments, thorn sonication was more efficient and recovery of following supercritical fluid extraction was higher.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026861
003      
CZ-PrNML
005      
20160318075258.0
007      
ta
008      
120816s2010 ne f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2010.07.020 $2 doi
035    __
$a (PubMed)20701916
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Klejdus, Bořivoj, $u Department of Chemistry and Biochemistry, Mendel University in Brno, Zemědělská 1, 613 00 Brno, Czech Republic. KlejdusB@seznam.cz $d 1958-2020 $7 xx0031057
245    10
$a Hyphenated technique for the extraction and determination of isoflavones in algae: ultrasound-assisted supercritical fluid extraction followed by fast chromatography with tandem mass spectrometry / $c B. Klejdus, L. Lojková, M. Plaza, M. Snóblová, D. Stěrbová,
520    9_
$a New hyphenated technique for the extraction and determination of isoflavones in sea and freshwater algae and cyanobacteria was developed. The method consists of sonication sample pretreatment, extraction by supercritical CO(2) modified by 3% (v/v) of MeOH/H(2)O mixture (9:1, v/v) at 35 MPa and 40°C for 60 min, fast chromatography analysis by the means of Agilent 1200 Series Rapid Resolution and MS/MS determination. Agilent 1200 Series RRLC was used with Zorbax SB-CN chromatographic column (100 mm × 2.1mm, particle size 3.5 μm), 3μl injection volume, mobile phase consisting of 0.2% (v/v) acetic acid in water (solvent A) and acetonitrile (solvent B) and used with linear gradient (30% B at 0 min, from 0 min to 3 min up to 50% B, from 3 to 6 min up to 80% B and from 6 to 10 min down to 30% B). The flow-rate was 0.4 mL/min, column oven temperature 35°C. MS detector Agilent Technologies 6460 Triple quadrupole LC/MS with Agilent Jet Stream was used in a negative ESI mode under following conditions: gas temperature 350°C, gas flow 13 L/min, nebulizer gas pressure 50 psi, sheath gas temperature 400°C, sheath gas flow 12L/min, capillary voltage was 4 kV. Samples were analysed in the multiple reaction monitoring (MRM) mode. Eight isoflavone compounds were found for the first time in seven real samples of sea algae and in three control samples of freshwater algae and cyanobacteria. Usual optimisation study of extraction parameters was performed. Pressure and temperature optima for algae matrix are different from those obtained sooner for other matrices for most of the analytes, but the results of modifier optimisation study are in good accordance with those obtained sooner for spiked samples and red clover matrix. It seems that matrix has very small or no effect on the modifier selection. Two different approaches of sonication pretreatment were tested: sonication bath and the thorn instrument. In longer extraction time experiments, thorn sonication was more efficient and recovery of following supercritical fluid extraction was higher.
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a superkritická fluidní chromatografie $x přístrojové vybavení $x metody $7 D025924
650    _2
$a isoflavony $x analýza $x izolace a purifikace $7 D007529
650    _2
$a Phaeophyceae $x chemie $7 D000459
650    _2
$a Rhodophyta $x chemie $7 D000461
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a ultrazvuk $7 D014465
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Lojková, Lea $7 _BN003740
700    1_
$a Plaza, M
700    1_
$a Šnóblová, Marie $7 xx0106083
700    1_
$a Štěrbová, Dagmar $7 xx0246731
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1217, č. 51 (2010), s. 7956-7965
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20701916 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120816 $b ABA008
991    __
$a 20160318075320 $b ABA008
999    __
$a ok $b bmc $g 948903 $s 784207
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 1217 $c 51 $d 7956-7965 $e 20100716 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$b NLK113 $a Pubmed-20120816/11/01

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...