Something wrong with this record ?
TVT-S in the U position--anatomical study
Petr Hubka, Ondrej Nanka, Alois Martan, Milos Grim, Jana Zvarova, Jaromir Masata
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
Grant support
NS10586
MZ0
CEP Register
Digital library NLK
Full text - Article
Source
NLK
ProQuest Central
from 1997-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2010-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 1997-01-01 to 1 year ago
- MeSH
- Fixatives MeSH
- Formaldehyde MeSH
- Gynecologic Surgical Procedures MeSH
- Humans MeSH
- Urinary Bladder anatomy & histology MeSH
- Obturator Nerve anatomy & histology MeSH
- Pelvis blood supply innervation MeSH
- Urinary Incontinence, Stress surgery MeSH
- Suburethral Slings MeSH
- Check Tag
- Humans MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
INTRODUCTION AND HYPOTHESIS: The objective is to describe the anatomical position of tension-free vaginal tape Secur (TVT-S) in the U position regarding possible injury and fixation site. METHODS: We placed TVT-S inserters bilaterally in 13 embalmed and five fresh frozen female bodies. After dissection, we measured distances from the obturator bundle. RESULTS: In embalmed bodies, the mean distance of TVT-S from the obturator bundle was 2.83 cm (standard deviation (SD) 0.87 cm) on the left, 2.92 cm (SD 1.24 cm) on the right. Perforation of the fascia of obturator internus muscle occurred in 38.5%. In fresh frozen bodies, results were fundamentally similar (p > 0.05). CONCLUSIONS: There is a risk of injury to the obturator bundle and urinary bladder during TVT-S; however, there is a significant risk of inserting the TVT-S inserter outside the obturator internus muscle (into the lesser pelvis). The position of TVT-S does not change significantly after legs mal-positioning.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027373
- 003
- CZ-PrNML
- 005
- 20160225143420.0
- 007
- ta
- 008
- 120816s2011 enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00192-010-1239-5 $2 doi
- 035 __
- $a (PubMed)20798925
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Hubka, Petr $u Department of Gynaecology and Obstetrics, First Faculty of Medicine and General Teaching Hospital, Charles University in Prague, Prague, Czech Republic. petr.hubka@centrum.cz $7 xx0128583
- 245 10
- $a TVT-S in the U position--anatomical study / $c Petr Hubka, Ondrej Nanka, Alois Martan, Milos Grim, Jana Zvarova, Jaromir Masata
- 520 9_
- $a INTRODUCTION AND HYPOTHESIS: The objective is to describe the anatomical position of tension-free vaginal tape Secur (TVT-S) in the U position regarding possible injury and fixation site. METHODS: We placed TVT-S inserters bilaterally in 13 embalmed and five fresh frozen female bodies. After dissection, we measured distances from the obturator bundle. RESULTS: In embalmed bodies, the mean distance of TVT-S from the obturator bundle was 2.83 cm (standard deviation (SD) 0.87 cm) on the left, 2.92 cm (SD 1.24 cm) on the right. Perforation of the fascia of obturator internus muscle occurred in 38.5%. In fresh frozen bodies, results were fundamentally similar (p > 0.05). CONCLUSIONS: There is a risk of injury to the obturator bundle and urinary bladder during TVT-S; however, there is a significant risk of inserting the TVT-S inserter outside the obturator internus muscle (into the lesser pelvis). The position of TVT-S does not change significantly after legs mal-positioning.
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a fixativa $7 D005404
- 650 _2
- $a formaldehyd $7 D005557
- 650 _2
- $a gynekologické chirurgické výkony $7 D013509
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a nervus obturatorius $x anatomie a histologie $7 D009776
- 650 _2
- $a pánev $x krevní zásobení $x inervace $7 D010388
- 650 _2
- $a suburetrální pásky $7 D053825
- 650 _2
- $a močový měchýř $x anatomie a histologie $7 D001743
- 650 _2
- $a stresová inkontinence moči $x chirurgie $7 D014550
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Nanka, Ondrej $u Institute of Anatomy, First Faculty of Medicine, Charles University in Prague, Prague, Czech Republic
- 700 1_
- $a Martan, Alois, $u Department of Gynaecology and Obstetrics, First Faculty of Medicine and General Teaching Hospital, Charles University in Prague, Prague, Czech Republic $d 1952- $7 nlk20010103172
- 700 1_
- $a Grim, Miloš, $u Institute of Anatomy, First Faculty of Medicine, Charles University in Prague, Prague, Czech Republic $d 1941- $7 jn20000602504
- 700 1_
- $a Zvárová, Jana, $u EuroMISE Center, Institute of Computer Sciences, Academy of Sciences of the Czech Republic, Prague, Czech Republic $d 1943-2017 $7 nlk19990074087
- 700 1_
- $a Mašata, Jaromír, $u Department of Gynaecology and Obstetrics, First Faculty of Medicine and General Teaching Hospital, Charles University in Prague, Prague, Czech Republic $d 1969- $7 mzk2004250988
- 773 0_
- $w MED00002395 $t International urogynecology journal $x 1433-3023 $g Roč. 22, č. 2 (2011), s. 241-246
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20798925 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20160225143137 $b ABA008
- 999 __
- $a ok $b bmc $g 949415 $s 784719
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 22 $c 2 $d 241-246 $i 1433-3023 $m International urogynecology journal $n Int. urogynecol. j. (Print) $x MED00002395
- GRA __
- $a NS10586 $p MZ0
- LZP __
- $b NLK112 $a Pubmed-20120816/11/02