-
Je něco špatně v tomto záznamu ?
The problems of proteinuria measurement in urine with presence of Bence Jones protein
V. Maisnar, M. Tichy, J. Stulik, J. Vavrova, B. Friedecky, V. Palicka, J. Spirkova, L. Zaloudkova, L. Hernychova, J. Spacilova, T. Buchler, R. Hajek
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NS10406
MZ0
CEP - Centrální evidence projektů
- MeSH
- 2D gelová elektroforéza MeSH
- Bence-Jonesova bílkovina moč MeSH
- lidé MeSH
- proteinurie moč MeSH
- reprodukovatelnost výsledků MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVES: Protein concentration measurement in the urine can be problematic in the presence of Bence Jones protein. We have carried out an external quality control assessment with the participation of 79 clinical biochemistry laboratories from the Czech Republic and Slovakia. DESIGN AND METHODS: The laboratories received a reference urine sample obtained from a patient with multiple myeloma and lambda free light chain proteinuria and were asked to type the paraprotein using immunofixation and to measure total urinary protein using their established method, most commonly turbidimetry, pyrogallol red assay, and biuret assay. RESULTS: There was a very wide inter-laboratory variability in the protein concentration readouts with up to three-fold difference in some cases. High-resolution two-dimensional electrophoresis and linear mass spectrometry showed that a high proportion of the urinary paraprotein was composed of lambda light chain fragments with molecular weight of 12kDa. CONCLUSIONS: Our results highlight the challenges of reliable and reproducible measurement of urinary protein concentration in the presence of Bence Jones protein.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027840
- 003
- CZ-PrNML
- 005
- 20141216151146.0
- 007
- ta
- 008
- 120817e20110201xxu f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.clinbiochem.2011.01.008 $2 doi
- 035 __
- $a (PubMed)21291878
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Maisnar, Vladimír $7 xx0062937 $u 2nd Department of Internal Medicine-Division of Clinical Hematology, Charles University Faculty of Medicine and University Hospital, Sokolska 581, 500 05 Hradec Kralove, Czech Republic. maisnar@fnhk.cz
- 245 14
- $a The problems of proteinuria measurement in urine with presence of Bence Jones protein / $c V. Maisnar, M. Tichy, J. Stulik, J. Vavrova, B. Friedecky, V. Palicka, J. Spirkova, L. Zaloudkova, L. Hernychova, J. Spacilova, T. Buchler, R. Hajek
- 520 9_
- $a OBJECTIVES: Protein concentration measurement in the urine can be problematic in the presence of Bence Jones protein. We have carried out an external quality control assessment with the participation of 79 clinical biochemistry laboratories from the Czech Republic and Slovakia. DESIGN AND METHODS: The laboratories received a reference urine sample obtained from a patient with multiple myeloma and lambda free light chain proteinuria and were asked to type the paraprotein using immunofixation and to measure total urinary protein using their established method, most commonly turbidimetry, pyrogallol red assay, and biuret assay. RESULTS: There was a very wide inter-laboratory variability in the protein concentration readouts with up to three-fold difference in some cases. High-resolution two-dimensional electrophoresis and linear mass spectrometry showed that a high proportion of the urinary paraprotein was composed of lambda light chain fragments with molecular weight of 12kDa. CONCLUSIONS: Our results highlight the challenges of reliable and reproducible measurement of urinary protein concentration in the presence of Bence Jones protein.
- 650 _2
- $a Bence-Jonesova bílkovina $x moč $7 D001536
- 650 _2
- $a 2D gelová elektroforéza $7 D015180
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a proteinurie $x moč $7 D011507
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a spektrometrie hmotnostní - ionizace laserem za účasti matrice $7 D019032
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Tichý, M
- 700 1_
- $a Stulik, J
- 700 1_
- $a Vavrova, J
- 700 1_
- $a Friedecky, B
- 700 1_
- $a Palička, Vladimír, $d 1946- $7 jn99240000830
- 700 1_
- $a Spirková, J
- 700 1_
- $a Žaloudková, Lenka $7 xx0112134
- 700 1_
- $a Hernychová, Lenka, $d 1965- $7 xx0073983
- 700 1_
- $a Spáčilová, J
- 700 1_
- $a Büchler, Tomáš, $7 xx0096851 $d 1974-
- 700 1_
- $a Hájek, Roman, $d 1964- $7 nlk20000083645
- 773 0_
- $w MED00001119 $t Clinical biochemistry $x 1873-2933 $g Roč. 44, č. 5-6 (20110201), s. 403-405
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21291878 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20141216151254 $b ABA008
- 999 __
- $a ok $b bmc $g 949882 $s 785186
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 44 $c 5-6 $d 403-405 $e 20110201 $i 1873-2933 $m Clinical biochemistry $n Clin Biochem $x MED00001119
- GRA __
- $a NS10406 $p MZ0
- LZP __
- $a Pubmed-20120817/11/03