• Je něco špatně v tomto záznamu ?

Peroperative optical autofluorescence biopsy--verification of its diagnostic potential

V. Ducháč, J. Zavadil, J. Vránová, T. Jirásek, J. Stukavec, L. Horák,

. 2011 ; 26 (3) : 325-33.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu hodnotící studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12027941
E-zdroje Online Plný text

NLK ProQuest Central od 2002-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2003-05-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest) od 2002-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2002-01-01 do Před 1 rokem

The authors tested the diagnostic potential of the portable autofluorescence optical system that was developed in the preoperative evaluation of resection margins, and thus of the resection line safety in patients with low-positioned colorectal carcinoma. A total of 217 spectral measurements of the fluorescence properties of normal (117) and malignant (100) tissues in 19 patients with colorectal carcinoma were accomplished. The measured spectra thus acquired were then evaluated using logistic regression. Using the principal component method, the authors selected the 30 and 40 most significant wavelengths, respectively, which they then used to construct the logistic model. The model met the basic criteria of statistical significance. The classification power of the model was 79.7% (for 30 wavelengths) and 82.5% (for 40). Statistical discrimination was 0.88 and 0.91, respectively. These results confirm that the optical setup that we selected is suitable for the peroperative testing of the distal resection line. It is capable of differentiating with 90% confidence pathological tissue and thus of reliably guiding further histological processing.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12027941
003      
CZ-PrNML
005      
20121207122529.0
007      
ta
008      
120817s2011 enk f 000 0#eng||
009      
AR
024    7_
$a 10.1007/s10103-010-0847-0 $2 doi
035    __
$a (PubMed)21053040
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Ducháč, Vitezslav $u Surgical Clinic of the 3rd Medical Faculty, Charles University, Prague, Šrobárova 55, 100 00, Prague 10, Czech Republic. duchac@fnkv.cz
245    10
$a Peroperative optical autofluorescence biopsy--verification of its diagnostic potential / $c V. Ducháč, J. Zavadil, J. Vránová, T. Jirásek, J. Stukavec, L. Horák,
520    9_
$a The authors tested the diagnostic potential of the portable autofluorescence optical system that was developed in the preoperative evaluation of resection margins, and thus of the resection line safety in patients with low-positioned colorectal carcinoma. A total of 217 spectral measurements of the fluorescence properties of normal (117) and malignant (100) tissues in 19 patients with colorectal carcinoma were accomplished. The measured spectra thus acquired were then evaluated using logistic regression. Using the principal component method, the authors selected the 30 and 40 most significant wavelengths, respectively, which they then used to construct the logistic model. The model met the basic criteria of statistical significance. The classification power of the model was 79.7% (for 30 wavelengths) and 82.5% (for 40). Statistical discrimination was 0.88 and 0.91, respectively. These results confirm that the optical setup that we selected is suitable for the peroperative testing of the distal resection line. It is capable of differentiating with 90% confidence pathological tissue and thus of reliably guiding further histological processing.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a biopsie $x přístrojové vybavení $x metody $x statistika a číselné údaje $7 D001706
650    _2
$a kolorektální nádory $x diagnóza $x chirurgie $7 D015179
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a fluorescence $7 D005453
650    _2
$a lidé $7 D006801
650    _2
$a peroperační doba $7 D007432
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a optické prostředky $7 D055096
650    _2
$a optická vlákna $7 D055100
650    _2
$a optické jevy $7 D055620
650    _2
$a fluorescenční spektrometrie $7 D013050
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
700    1_
$a Zavadil, Jiri
700    1_
$a Vránová, Jana
700    1_
$a Jirásek, Tomas
700    1_
$a Stukavec, Jan
700    1_
$a Horák, Ladislav
773    0_
$w MED00005769 $t Lasers in medical science $x 1435-604X $g Roč. 26, č. 3 (2011), s. 325-33
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21053040 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121207122603 $b ABA008
999    __
$a ok $b bmc $g 949983 $s 785287
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 26 $c 3 $d 325-33 $i 1435-604X $m Lasers in medical science $n Lasers Med Sci $x MED00005769
LZP    __
$a Pubmed-20120817/11/03

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...